Cargando…

Clinical Response After Treatment of Knee Osteoarthritis With a Standardized, Closed-System, Low-Cost Platelet-Rich Plasma Product: 1-Year Outcomes

BACKGROUND: Intra-articular infiltration of platelet-rich plasma (PRP) is an alternative therapeutic option to classic hyaluronic acid for the treatment of symptomatic knee osteoarthritis (KOA). However, variation in preparation methods and quality assessment of PRP makes the study of its real clini...

Descripción completa

Detalles Bibliográficos
Autores principales: Fernández-Fuertes, Judit, Arias-Fernández, Tamara, Acebes-Huerta, Andrea, Álvarez-Rico, Marlene, Gutiérrez, Laura
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8977725/
https://www.ncbi.nlm.nih.gov/pubmed/35387363
http://dx.doi.org/10.1177/23259671221076496
_version_ 1784680826373406720
author Fernández-Fuertes, Judit
Arias-Fernández, Tamara
Acebes-Huerta, Andrea
Álvarez-Rico, Marlene
Gutiérrez, Laura
author_facet Fernández-Fuertes, Judit
Arias-Fernández, Tamara
Acebes-Huerta, Andrea
Álvarez-Rico, Marlene
Gutiérrez, Laura
author_sort Fernández-Fuertes, Judit
collection PubMed
description BACKGROUND: Intra-articular infiltration of platelet-rich plasma (PRP) is an alternative therapeutic option to classic hyaluronic acid for the treatment of symptomatic knee osteoarthritis (KOA). However, variation in preparation methods and quality assessment of PRP makes the study of its real clinical efficacy difficult. PURPOSE: To (1) evaluate the clinical efficacy of a characterized PRP product prepared in a standardized manner and in a closed-system for the treatment of KOA and to (2) evaluate the association of the clinical response to PRP-related variables. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: We recruited 130 patients with nonoperative KOA and evaluated them for 1 year. PRP was prepared from a donation of autologous blood, obtaining 3 aliquots of approximately 10mL of product, which were frozen, allowing platelet disruption, platelet factor release, and long-term storage, until administration. Patients were treated 3 consecutive times every 4 weeks with an intra-articular PRP knee injection under sterile conditions. Complete blood count was performed on the whole-blood sample and the processed PRP before freezing it, for product quality assessment. Patients were assessed using the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and basic satisfaction scale at 3 months, 6 months, and 1 year after intervention. RESULTS: Quality assessment confirmed a leukocyte-poor PRP product (white blood cell count, 0.09 ± 0.09 × 10(9)/L) with a high platelet purity (platelet count, 630.86 ± 191.75 × 10(9)/L). WOMAC scores improved, and basic satisfaction was achieved in 70% of patients. No adverse events were reported. No correlations were observed between PRP quality parameters and clinical results. PRP complete treatment production costs were €108/US$125 (€36/US$41.6 per injection). CONCLUSION: This standardized PRP production method resulted in improved WOMAC scores at 1 year postoperatively in 70% of patients with KOA. This technique was safe and affordable and ensured consecutive infiltrations with the same product to each patient.
format Online
Article
Text
id pubmed-8977725
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-89777252022-04-05 Clinical Response After Treatment of Knee Osteoarthritis With a Standardized, Closed-System, Low-Cost Platelet-Rich Plasma Product: 1-Year Outcomes Fernández-Fuertes, Judit Arias-Fernández, Tamara Acebes-Huerta, Andrea Álvarez-Rico, Marlene Gutiérrez, Laura Orthop J Sports Med Article BACKGROUND: Intra-articular infiltration of platelet-rich plasma (PRP) is an alternative therapeutic option to classic hyaluronic acid for the treatment of symptomatic knee osteoarthritis (KOA). However, variation in preparation methods and quality assessment of PRP makes the study of its real clinical efficacy difficult. PURPOSE: To (1) evaluate the clinical efficacy of a characterized PRP product prepared in a standardized manner and in a closed-system for the treatment of KOA and to (2) evaluate the association of the clinical response to PRP-related variables. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: We recruited 130 patients with nonoperative KOA and evaluated them for 1 year. PRP was prepared from a donation of autologous blood, obtaining 3 aliquots of approximately 10mL of product, which were frozen, allowing platelet disruption, platelet factor release, and long-term storage, until administration. Patients were treated 3 consecutive times every 4 weeks with an intra-articular PRP knee injection under sterile conditions. Complete blood count was performed on the whole-blood sample and the processed PRP before freezing it, for product quality assessment. Patients were assessed using the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and basic satisfaction scale at 3 months, 6 months, and 1 year after intervention. RESULTS: Quality assessment confirmed a leukocyte-poor PRP product (white blood cell count, 0.09 ± 0.09 × 10(9)/L) with a high platelet purity (platelet count, 630.86 ± 191.75 × 10(9)/L). WOMAC scores improved, and basic satisfaction was achieved in 70% of patients. No adverse events were reported. No correlations were observed between PRP quality parameters and clinical results. PRP complete treatment production costs were €108/US$125 (€36/US$41.6 per injection). CONCLUSION: This standardized PRP production method resulted in improved WOMAC scores at 1 year postoperatively in 70% of patients with KOA. This technique was safe and affordable and ensured consecutive infiltrations with the same product to each patient. SAGE Publications 2022-03-31 /pmc/articles/PMC8977725/ /pubmed/35387363 http://dx.doi.org/10.1177/23259671221076496 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by-nc-nd/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 License (https://creativecommons.org/licenses/by-nc-nd/4.0/) which permits non-commercial use, reproduction and distribution of the work as published without adaptation or alteration, without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Article
Fernández-Fuertes, Judit
Arias-Fernández, Tamara
Acebes-Huerta, Andrea
Álvarez-Rico, Marlene
Gutiérrez, Laura
Clinical Response After Treatment of Knee Osteoarthritis With a Standardized, Closed-System, Low-Cost Platelet-Rich Plasma Product: 1-Year Outcomes
title Clinical Response After Treatment of Knee Osteoarthritis With a Standardized, Closed-System, Low-Cost Platelet-Rich Plasma Product: 1-Year Outcomes
title_full Clinical Response After Treatment of Knee Osteoarthritis With a Standardized, Closed-System, Low-Cost Platelet-Rich Plasma Product: 1-Year Outcomes
title_fullStr Clinical Response After Treatment of Knee Osteoarthritis With a Standardized, Closed-System, Low-Cost Platelet-Rich Plasma Product: 1-Year Outcomes
title_full_unstemmed Clinical Response After Treatment of Knee Osteoarthritis With a Standardized, Closed-System, Low-Cost Platelet-Rich Plasma Product: 1-Year Outcomes
title_short Clinical Response After Treatment of Knee Osteoarthritis With a Standardized, Closed-System, Low-Cost Platelet-Rich Plasma Product: 1-Year Outcomes
title_sort clinical response after treatment of knee osteoarthritis with a standardized, closed-system, low-cost platelet-rich plasma product: 1-year outcomes
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8977725/
https://www.ncbi.nlm.nih.gov/pubmed/35387363
http://dx.doi.org/10.1177/23259671221076496
work_keys_str_mv AT fernandezfuertesjudit clinicalresponseaftertreatmentofkneeosteoarthritiswithastandardizedclosedsystemlowcostplateletrichplasmaproduct1yearoutcomes
AT ariasfernandeztamara clinicalresponseaftertreatmentofkneeosteoarthritiswithastandardizedclosedsystemlowcostplateletrichplasmaproduct1yearoutcomes
AT acebeshuertaandrea clinicalresponseaftertreatmentofkneeosteoarthritiswithastandardizedclosedsystemlowcostplateletrichplasmaproduct1yearoutcomes
AT alvarezricomarlene clinicalresponseaftertreatmentofkneeosteoarthritiswithastandardizedclosedsystemlowcostplateletrichplasmaproduct1yearoutcomes
AT gutierrezlaura clinicalresponseaftertreatmentofkneeosteoarthritiswithastandardizedclosedsystemlowcostplateletrichplasmaproduct1yearoutcomes