Agreement in anterior segment measurements between swept-source and Scheimpflug-based optical biometries in keratoconic eyes: a pilot study

BACKGROUND: Cataract surgery in keratoconic patients is challenging because of the corneal distortion, which can lead to inaccurate keratometry readings. This study is a comparison of the accuracy of keratometry readings by two types of devices in a tertiary hospital. PURPOSE: To evaluate the compar...

Descripción completa

Detalles Bibliográficos
Autores principales: Chalkiadaki, Evangelia, Gartaganis, Panos S., Ntravalias, Thomas, Giannakis, Ioannis, Manousakis, Evangelos, Karmiris, Efthymios
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8978314/
https://www.ncbi.nlm.nih.gov/pubmed/35387236
http://dx.doi.org/10.1177/25158414211063283
_version_ 1784680939308187648
author Chalkiadaki, Evangelia
Gartaganis, Panos S.
Ntravalias, Thomas
Giannakis, Ioannis
Manousakis, Evangelos
Karmiris, Efthymios
author_facet Chalkiadaki, Evangelia
Gartaganis, Panos S.
Ntravalias, Thomas
Giannakis, Ioannis
Manousakis, Evangelos
Karmiris, Efthymios
author_sort Chalkiadaki, Evangelia
collection PubMed
description BACKGROUND: Cataract surgery in keratoconic patients is challenging because of the corneal distortion, which can lead to inaccurate keratometry readings. This study is a comparison of the accuracy of keratometry readings by two types of devices in a tertiary hospital. PURPOSE: To evaluate the comparability of corneal power measurements, anterior chamber depth (ACD), and white-to-white (WTW) distance between Scheimpflug-based tomography (Pentacam AXL; OCULUS GmbH, Wetzlar, Germany) and swept-source optical biometry (IOLMaster 700; Carl Zeiss Meditec AG, Jena, Germany) in patients with keratoconus. METHODS: This pilot, prospective, interinstrument reliability study included 30 keratoconic eyes of 15 individuals who had not undergone any kind of corneal surgery. Standard K and total refractive power (TK(®)) of the flattest and steepest axes of the IOLMaster 700 were compared with the standard keratometry (SimK), true net power (TNP), equivalent keratometer readings (EKR), and total corneal refractive power (TCRP) of the Pentacam. The Bland–Altman analysis was used to evaluate the agreement between the measurements of both devices. The paired-samples t-test and the Wilcoxon signed-rank test were performed to compare the mean values of the variables obtained with the devices. RESULTS: The K1 value of the IOLMaster 700 was significantly higher from EKR K1 along the 3-mm (mean difference: 0.79 diopters, p = 0.01), 4-mm (mean difference: 1.01 D, p = 0.01), and 4.5-mm zones (mean difference: 1.20 D, p = 0.01) and TNP K1 along the 3-mm (mean difference: 0.88 D, p < 0.001) and 4-mm zones (mean difference: 0.97 D, p < 0.001). The TK1 value was significantly higher from EKR K1 along the 2-mm (mean difference: 0.42 D, p = 0.04), 3-mm (mean difference: 0.83 D, p = 0.003), 4-mm (mean difference: 1.05 D, p = 0.004), and 4.5-mm zones (mean difference: 1.24 D, p = 0.005) and TNP K1 along the 3-mm (mean difference: 0.92 D, p < 0.001) and 4-mm zones (mean difference: 1.01 D, p < 0.001). The K2 value of the IOLMaster 700 was significantly higher from TK2 (mean difference: 0.11 D, p = 0.04) and all the corresponding variables of the Pentacam device. The TK2 value was significantly higher from all the corresponding variables of the Pentacam device. The Pentacam also yielded significantly lower values for the WTW distance (mean difference: 0.31 mm, p < 0.001) and no significant difference in terms of ACD values (p = 0.9). CONCLUSION: The IOLMaster measured significantly greater keratometry readings in the steep axis for all the variables studied. The keratometry and WTW measurements of the investigated devices cannot be used interchangeably in keratoconus.
format Online
Article
Text
id pubmed-8978314
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-89783142022-04-05 Agreement in anterior segment measurements between swept-source and Scheimpflug-based optical biometries in keratoconic eyes: a pilot study Chalkiadaki, Evangelia Gartaganis, Panos S. Ntravalias, Thomas Giannakis, Ioannis Manousakis, Evangelos Karmiris, Efthymios Ther Adv Ophthalmol Original Research BACKGROUND: Cataract surgery in keratoconic patients is challenging because of the corneal distortion, which can lead to inaccurate keratometry readings. This study is a comparison of the accuracy of keratometry readings by two types of devices in a tertiary hospital. PURPOSE: To evaluate the comparability of corneal power measurements, anterior chamber depth (ACD), and white-to-white (WTW) distance between Scheimpflug-based tomography (Pentacam AXL; OCULUS GmbH, Wetzlar, Germany) and swept-source optical biometry (IOLMaster 700; Carl Zeiss Meditec AG, Jena, Germany) in patients with keratoconus. METHODS: This pilot, prospective, interinstrument reliability study included 30 keratoconic eyes of 15 individuals who had not undergone any kind of corneal surgery. Standard K and total refractive power (TK(®)) of the flattest and steepest axes of the IOLMaster 700 were compared with the standard keratometry (SimK), true net power (TNP), equivalent keratometer readings (EKR), and total corneal refractive power (TCRP) of the Pentacam. The Bland–Altman analysis was used to evaluate the agreement between the measurements of both devices. The paired-samples t-test and the Wilcoxon signed-rank test were performed to compare the mean values of the variables obtained with the devices. RESULTS: The K1 value of the IOLMaster 700 was significantly higher from EKR K1 along the 3-mm (mean difference: 0.79 diopters, p = 0.01), 4-mm (mean difference: 1.01 D, p = 0.01), and 4.5-mm zones (mean difference: 1.20 D, p = 0.01) and TNP K1 along the 3-mm (mean difference: 0.88 D, p < 0.001) and 4-mm zones (mean difference: 0.97 D, p < 0.001). The TK1 value was significantly higher from EKR K1 along the 2-mm (mean difference: 0.42 D, p = 0.04), 3-mm (mean difference: 0.83 D, p = 0.003), 4-mm (mean difference: 1.05 D, p = 0.004), and 4.5-mm zones (mean difference: 1.24 D, p = 0.005) and TNP K1 along the 3-mm (mean difference: 0.92 D, p < 0.001) and 4-mm zones (mean difference: 1.01 D, p < 0.001). The K2 value of the IOLMaster 700 was significantly higher from TK2 (mean difference: 0.11 D, p = 0.04) and all the corresponding variables of the Pentacam device. The TK2 value was significantly higher from all the corresponding variables of the Pentacam device. The Pentacam also yielded significantly lower values for the WTW distance (mean difference: 0.31 mm, p < 0.001) and no significant difference in terms of ACD values (p = 0.9). CONCLUSION: The IOLMaster measured significantly greater keratometry readings in the steep axis for all the variables studied. The keratometry and WTW measurements of the investigated devices cannot be used interchangeably in keratoconus. SAGE Publications 2022-03-31 /pmc/articles/PMC8978314/ /pubmed/35387236 http://dx.doi.org/10.1177/25158414211063283 Text en © The Author(s), 2022 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Research
Chalkiadaki, Evangelia
Gartaganis, Panos S.
Ntravalias, Thomas
Giannakis, Ioannis
Manousakis, Evangelos
Karmiris, Efthymios
Agreement in anterior segment measurements between swept-source and Scheimpflug-based optical biometries in keratoconic eyes: a pilot study
title Agreement in anterior segment measurements between swept-source and Scheimpflug-based optical biometries in keratoconic eyes: a pilot study
title_full Agreement in anterior segment measurements between swept-source and Scheimpflug-based optical biometries in keratoconic eyes: a pilot study
title_fullStr Agreement in anterior segment measurements between swept-source and Scheimpflug-based optical biometries in keratoconic eyes: a pilot study
title_full_unstemmed Agreement in anterior segment measurements between swept-source and Scheimpflug-based optical biometries in keratoconic eyes: a pilot study
title_short Agreement in anterior segment measurements between swept-source and Scheimpflug-based optical biometries in keratoconic eyes: a pilot study
title_sort agreement in anterior segment measurements between swept-source and scheimpflug-based optical biometries in keratoconic eyes: a pilot study
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8978314/
https://www.ncbi.nlm.nih.gov/pubmed/35387236
http://dx.doi.org/10.1177/25158414211063283
work_keys_str_mv AT chalkiadakievangelia agreementinanteriorsegmentmeasurementsbetweensweptsourceandscheimpflugbasedopticalbiometriesinkeratoconiceyesapilotstudy
AT gartaganispanoss agreementinanteriorsegmentmeasurementsbetweensweptsourceandscheimpflugbasedopticalbiometriesinkeratoconiceyesapilotstudy
AT ntravaliasthomas agreementinanteriorsegmentmeasurementsbetweensweptsourceandscheimpflugbasedopticalbiometriesinkeratoconiceyesapilotstudy
AT giannakisioannis agreementinanteriorsegmentmeasurementsbetweensweptsourceandscheimpflugbasedopticalbiometriesinkeratoconiceyesapilotstudy
AT manousakisevangelos agreementinanteriorsegmentmeasurementsbetweensweptsourceandscheimpflugbasedopticalbiometriesinkeratoconiceyesapilotstudy
AT karmirisefthymios agreementinanteriorsegmentmeasurementsbetweensweptsourceandscheimpflugbasedopticalbiometriesinkeratoconiceyesapilotstudy