Cargando…

Mean drop behavior in the standard liquid–liquid extraction systems on an L-shaped pulsed sieve-plate column: experiment and modeling

In this study, the effect of operating parameters on drop behavior was investigated experimentally in an L-shaped pulsed sieve-plate column (LPSPC). LPSPC offers enhanced efficiency due to a high mixing rate provided by pneumatic or hydraulic pulsation of the liquids, which makes the dispersed phase...

Descripción completa

Detalles Bibliográficos
Autores principales: Ardestani, Fatemeh, Ghaemi, Ahad, Safdari, Jaber, Hemmati, Alireza
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society of Chemistry 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8981092/
https://www.ncbi.nlm.nih.gov/pubmed/35425447
http://dx.doi.org/10.1039/d1ra08723a
_version_ 1784681529898696704
author Ardestani, Fatemeh
Ghaemi, Ahad
Safdari, Jaber
Hemmati, Alireza
author_facet Ardestani, Fatemeh
Ghaemi, Ahad
Safdari, Jaber
Hemmati, Alireza
author_sort Ardestani, Fatemeh
collection PubMed
description In this study, the effect of operating parameters on drop behavior was investigated experimentally in an L-shaped pulsed sieve-plate column (LPSPC). LPSPC offers enhanced efficiency due to a high mixing rate provided by pneumatic or hydraulic pulsation of the liquids, which makes the dispersed phase drops coalesce and break. The response surface methodology (RSM) based on the central composite design (CCD) approach was applied for experimental modeling of three standard systems including toluene–water, butyl acetate–water, and butanol–water. Four parameters including pulsation intensity, interfacial tension, dispersion, and continuous phase velocities were examined in the experiments. Experimental results indicated that an increase in the pulsation intensity led to a decrease in Sauter mean diameter (SMD), and an increase in the flow rates of the phase cause an increase in SMD, although the effect of the flow rates on SMD was much lower than the pulsation intensity. Based on the obtained experimental data, new correlations have been proposed to predict SMD in two sections of the column tested by the goodness-of-fit statistics through analysis of variance. The coefficient of determination was achieved at 0.998 and 0.978 for horizontal and vertical sections, respectively, which demonstrated that the presented models estimated the experimental values very well. The optimum SMDs were obtained at 0.789 mm and 0.639 mm for the horizontal and vertical sections, respectively.
format Online
Article
Text
id pubmed-8981092
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher The Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-89810922022-04-13 Mean drop behavior in the standard liquid–liquid extraction systems on an L-shaped pulsed sieve-plate column: experiment and modeling Ardestani, Fatemeh Ghaemi, Ahad Safdari, Jaber Hemmati, Alireza RSC Adv Chemistry In this study, the effect of operating parameters on drop behavior was investigated experimentally in an L-shaped pulsed sieve-plate column (LPSPC). LPSPC offers enhanced efficiency due to a high mixing rate provided by pneumatic or hydraulic pulsation of the liquids, which makes the dispersed phase drops coalesce and break. The response surface methodology (RSM) based on the central composite design (CCD) approach was applied for experimental modeling of three standard systems including toluene–water, butyl acetate–water, and butanol–water. Four parameters including pulsation intensity, interfacial tension, dispersion, and continuous phase velocities were examined in the experiments. Experimental results indicated that an increase in the pulsation intensity led to a decrease in Sauter mean diameter (SMD), and an increase in the flow rates of the phase cause an increase in SMD, although the effect of the flow rates on SMD was much lower than the pulsation intensity. Based on the obtained experimental data, new correlations have been proposed to predict SMD in two sections of the column tested by the goodness-of-fit statistics through analysis of variance. The coefficient of determination was achieved at 0.998 and 0.978 for horizontal and vertical sections, respectively, which demonstrated that the presented models estimated the experimental values very well. The optimum SMDs were obtained at 0.789 mm and 0.639 mm for the horizontal and vertical sections, respectively. The Royal Society of Chemistry 2022-02-02 /pmc/articles/PMC8981092/ /pubmed/35425447 http://dx.doi.org/10.1039/d1ra08723a Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by-nc/3.0/
spellingShingle Chemistry
Ardestani, Fatemeh
Ghaemi, Ahad
Safdari, Jaber
Hemmati, Alireza
Mean drop behavior in the standard liquid–liquid extraction systems on an L-shaped pulsed sieve-plate column: experiment and modeling
title Mean drop behavior in the standard liquid–liquid extraction systems on an L-shaped pulsed sieve-plate column: experiment and modeling
title_full Mean drop behavior in the standard liquid–liquid extraction systems on an L-shaped pulsed sieve-plate column: experiment and modeling
title_fullStr Mean drop behavior in the standard liquid–liquid extraction systems on an L-shaped pulsed sieve-plate column: experiment and modeling
title_full_unstemmed Mean drop behavior in the standard liquid–liquid extraction systems on an L-shaped pulsed sieve-plate column: experiment and modeling
title_short Mean drop behavior in the standard liquid–liquid extraction systems on an L-shaped pulsed sieve-plate column: experiment and modeling
title_sort mean drop behavior in the standard liquid–liquid extraction systems on an l-shaped pulsed sieve-plate column: experiment and modeling
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8981092/
https://www.ncbi.nlm.nih.gov/pubmed/35425447
http://dx.doi.org/10.1039/d1ra08723a
work_keys_str_mv AT ardestanifatemeh meandropbehaviorinthestandardliquidliquidextractionsystemsonanlshapedpulsedsieveplatecolumnexperimentandmodeling
AT ghaemiahad meandropbehaviorinthestandardliquidliquidextractionsystemsonanlshapedpulsedsieveplatecolumnexperimentandmodeling
AT safdarijaber meandropbehaviorinthestandardliquidliquidextractionsystemsonanlshapedpulsedsieveplatecolumnexperimentandmodeling
AT hemmatialireza meandropbehaviorinthestandardliquidliquidextractionsystemsonanlshapedpulsedsieveplatecolumnexperimentandmodeling