Cargando…
Accuracy of intravitreal injection volume for aflibercept pre-filled syringe and BD Luer-Lok one-milliliter syringe
BACKGROUND: To evaluate the accuracy of intravitreal injection volume of the pre-filled syringe (PFS) in which aflibercept is packaged compared to the BD Luer-Lok 1-mL syringe. METHODS: Ophthalmologists injected their typical intravitreal volume for aflibercept using either the PFS or BD Luer-Lok 1-...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8981608/ https://www.ncbi.nlm.nih.gov/pubmed/35382900 http://dx.doi.org/10.1186/s40942-022-00375-3 |
_version_ | 1784681637628346368 |
---|---|
author | Guest, John-Michael Malbin, Brett Abrams, Gary Parendo, Anthony Das, Shibandri Okeagu, Chinwenwa Ross, Bing X. Kumar, Ashok Lin, Xihui |
author_facet | Guest, John-Michael Malbin, Brett Abrams, Gary Parendo, Anthony Das, Shibandri Okeagu, Chinwenwa Ross, Bing X. Kumar, Ashok Lin, Xihui |
author_sort | Guest, John-Michael |
collection | PubMed |
description | BACKGROUND: To evaluate the accuracy of intravitreal injection volume of the pre-filled syringe (PFS) in which aflibercept is packaged compared to the BD Luer-Lok 1-mL syringe. METHODS: Ophthalmologists injected their typical intravitreal volume for aflibercept using either the PFS or BD Luer-Lok 1-mL syringe for 5 times each. The injected fluid was weighed using a micro-scale and converted to volume. The volume of fluid injected was also evaluated when the 0.05 mL line on the PFS was lined up to the tip or base of the dome-shaped plunger. RESULTS: Injection volume was measured for 12 physicians. The average injected fluid volume was 74.22 ± 15.87 µL for PFS and 53.42 ± 4.61 µL for the BD Luer-Lok 1-mL syringe (p < 0.0001). The average deviation in volume injected for the PFS was higher compared to the BD Luer-Lok 1-mL syringe (11.36 µL vs. 3.35 µL, p < 0.0001). When the PFS was lined up with the tip of the dome-shaped plunger at the 0.05-mL line, the average injected volume was 71.03% higher. CONCLUSIONS: The intravitreal injection volume and variability using the new PFS were significantly higher than the volume injected using the BD Luer-Lok 1-mL syringe previously used, potentially leading to higher rates of visually significant elevation of intraocular pressures. |
format | Online Article Text |
id | pubmed-8981608 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-89816082022-04-06 Accuracy of intravitreal injection volume for aflibercept pre-filled syringe and BD Luer-Lok one-milliliter syringe Guest, John-Michael Malbin, Brett Abrams, Gary Parendo, Anthony Das, Shibandri Okeagu, Chinwenwa Ross, Bing X. Kumar, Ashok Lin, Xihui Int J Retina Vitreous Original Article BACKGROUND: To evaluate the accuracy of intravitreal injection volume of the pre-filled syringe (PFS) in which aflibercept is packaged compared to the BD Luer-Lok 1-mL syringe. METHODS: Ophthalmologists injected their typical intravitreal volume for aflibercept using either the PFS or BD Luer-Lok 1-mL syringe for 5 times each. The injected fluid was weighed using a micro-scale and converted to volume. The volume of fluid injected was also evaluated when the 0.05 mL line on the PFS was lined up to the tip or base of the dome-shaped plunger. RESULTS: Injection volume was measured for 12 physicians. The average injected fluid volume was 74.22 ± 15.87 µL for PFS and 53.42 ± 4.61 µL for the BD Luer-Lok 1-mL syringe (p < 0.0001). The average deviation in volume injected for the PFS was higher compared to the BD Luer-Lok 1-mL syringe (11.36 µL vs. 3.35 µL, p < 0.0001). When the PFS was lined up with the tip of the dome-shaped plunger at the 0.05-mL line, the average injected volume was 71.03% higher. CONCLUSIONS: The intravitreal injection volume and variability using the new PFS were significantly higher than the volume injected using the BD Luer-Lok 1-mL syringe previously used, potentially leading to higher rates of visually significant elevation of intraocular pressures. BioMed Central 2022-04-05 /pmc/articles/PMC8981608/ /pubmed/35382900 http://dx.doi.org/10.1186/s40942-022-00375-3 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Original Article Guest, John-Michael Malbin, Brett Abrams, Gary Parendo, Anthony Das, Shibandri Okeagu, Chinwenwa Ross, Bing X. Kumar, Ashok Lin, Xihui Accuracy of intravitreal injection volume for aflibercept pre-filled syringe and BD Luer-Lok one-milliliter syringe |
title | Accuracy of intravitreal injection volume for aflibercept pre-filled syringe and BD Luer-Lok one-milliliter syringe |
title_full | Accuracy of intravitreal injection volume for aflibercept pre-filled syringe and BD Luer-Lok one-milliliter syringe |
title_fullStr | Accuracy of intravitreal injection volume for aflibercept pre-filled syringe and BD Luer-Lok one-milliliter syringe |
title_full_unstemmed | Accuracy of intravitreal injection volume for aflibercept pre-filled syringe and BD Luer-Lok one-milliliter syringe |
title_short | Accuracy of intravitreal injection volume for aflibercept pre-filled syringe and BD Luer-Lok one-milliliter syringe |
title_sort | accuracy of intravitreal injection volume for aflibercept pre-filled syringe and bd luer-lok one-milliliter syringe |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8981608/ https://www.ncbi.nlm.nih.gov/pubmed/35382900 http://dx.doi.org/10.1186/s40942-022-00375-3 |
work_keys_str_mv | AT guestjohnmichael accuracyofintravitrealinjectionvolumeforafliberceptprefilledsyringeandbdluerlokonemillilitersyringe AT malbinbrett accuracyofintravitrealinjectionvolumeforafliberceptprefilledsyringeandbdluerlokonemillilitersyringe AT abramsgary accuracyofintravitrealinjectionvolumeforafliberceptprefilledsyringeandbdluerlokonemillilitersyringe AT parendoanthony accuracyofintravitrealinjectionvolumeforafliberceptprefilledsyringeandbdluerlokonemillilitersyringe AT dasshibandri accuracyofintravitrealinjectionvolumeforafliberceptprefilledsyringeandbdluerlokonemillilitersyringe AT okeaguchinwenwa accuracyofintravitrealinjectionvolumeforafliberceptprefilledsyringeandbdluerlokonemillilitersyringe AT rossbingx accuracyofintravitrealinjectionvolumeforafliberceptprefilledsyringeandbdluerlokonemillilitersyringe AT kumarashok accuracyofintravitrealinjectionvolumeforafliberceptprefilledsyringeandbdluerlokonemillilitersyringe AT linxihui accuracyofintravitrealinjectionvolumeforafliberceptprefilledsyringeandbdluerlokonemillilitersyringe |