Cargando…
Modeling of mitral chordae’s length in echocardiography as a function of their manual measurement in the operating room
OBJECTIVE: In mitral insufficiency, trans-esophageal echocardiography (TEE) analysis of the mitral valve is an indispensable and irreplaceable examination to establish precisely the type of surgical repair to be performed and the exact length of neo-chordae to be used for an anatomical repair. The a...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8981775/ https://www.ncbi.nlm.nih.gov/pubmed/35379261 http://dx.doi.org/10.1186/s13019-022-01816-8 |
_version_ | 1784681673107963904 |
---|---|
author | Gun, Mesut Barry, Misbaou Bohbot, Yohann Tribouilloy, Christophe Touati, Gilles |
author_facet | Gun, Mesut Barry, Misbaou Bohbot, Yohann Tribouilloy, Christophe Touati, Gilles |
author_sort | Gun, Mesut |
collection | PubMed |
description | OBJECTIVE: In mitral insufficiency, trans-esophageal echocardiography (TEE) analysis of the mitral valve is an indispensable and irreplaceable examination to establish precisely the type of surgical repair to be performed and the exact length of neo-chordae to be used for an anatomical repair. The aim of our study is to find a predictive model of the Echographic Measurement (EM) variable according to the Manual Measurement (MM) variable of the mitral valve chordae, when the echocardiography measurement is not feasible. PATIENTS AND METHODS: This is a retrospective study on 191 patients undergoing mitral valve repair. The sex ratio (M/F) is 2.13 (130 men and 61 women). The collection of data of mitral chordae measurements performed echographically in preoperatively conditions, and then manually in intraoperatively conditions from January 2008 to December 2016 was made from the medical records of patients at the cardiology and cardiac surgery department of the University Hospital Center of Amiens in Picardy. RESULTS: For this study 191 patients of mean age of 68 ± 13 years were included. The averages of the MM and EM of the mitral chordae were respectively 23 ± 2.5 mm and 24 ± 2.4 mm. The Pearson correlation coefficient was 0.897 (p-value < 10(−4)) showing a strong positive correlation between MM and EM. The results of the linear regression allow us to found the following mathematical model: EM = 0.87 × MM + 4. CONCLUSIONS: When patients have a contraindication to transesophageal echocardiography or when TEE is not feasible, manual measurement is performed during the surgery. By using the values obtained (MM) in the model, it is possible to predict the corresponding echographic measurements. This allows us to achieve the mitral tendinous chordae substitution with a very high precision. Trial registration: Retrospectively registered. |
format | Online Article Text |
id | pubmed-8981775 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-89817752022-04-06 Modeling of mitral chordae’s length in echocardiography as a function of their manual measurement in the operating room Gun, Mesut Barry, Misbaou Bohbot, Yohann Tribouilloy, Christophe Touati, Gilles J Cardiothorac Surg Research Article OBJECTIVE: In mitral insufficiency, trans-esophageal echocardiography (TEE) analysis of the mitral valve is an indispensable and irreplaceable examination to establish precisely the type of surgical repair to be performed and the exact length of neo-chordae to be used for an anatomical repair. The aim of our study is to find a predictive model of the Echographic Measurement (EM) variable according to the Manual Measurement (MM) variable of the mitral valve chordae, when the echocardiography measurement is not feasible. PATIENTS AND METHODS: This is a retrospective study on 191 patients undergoing mitral valve repair. The sex ratio (M/F) is 2.13 (130 men and 61 women). The collection of data of mitral chordae measurements performed echographically in preoperatively conditions, and then manually in intraoperatively conditions from January 2008 to December 2016 was made from the medical records of patients at the cardiology and cardiac surgery department of the University Hospital Center of Amiens in Picardy. RESULTS: For this study 191 patients of mean age of 68 ± 13 years were included. The averages of the MM and EM of the mitral chordae were respectively 23 ± 2.5 mm and 24 ± 2.4 mm. The Pearson correlation coefficient was 0.897 (p-value < 10(−4)) showing a strong positive correlation between MM and EM. The results of the linear regression allow us to found the following mathematical model: EM = 0.87 × MM + 4. CONCLUSIONS: When patients have a contraindication to transesophageal echocardiography or when TEE is not feasible, manual measurement is performed during the surgery. By using the values obtained (MM) in the model, it is possible to predict the corresponding echographic measurements. This allows us to achieve the mitral tendinous chordae substitution with a very high precision. Trial registration: Retrospectively registered. BioMed Central 2022-04-04 /pmc/articles/PMC8981775/ /pubmed/35379261 http://dx.doi.org/10.1186/s13019-022-01816-8 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Gun, Mesut Barry, Misbaou Bohbot, Yohann Tribouilloy, Christophe Touati, Gilles Modeling of mitral chordae’s length in echocardiography as a function of their manual measurement in the operating room |
title | Modeling of mitral chordae’s length in echocardiography as a function of their manual measurement in the operating room |
title_full | Modeling of mitral chordae’s length in echocardiography as a function of their manual measurement in the operating room |
title_fullStr | Modeling of mitral chordae’s length in echocardiography as a function of their manual measurement in the operating room |
title_full_unstemmed | Modeling of mitral chordae’s length in echocardiography as a function of their manual measurement in the operating room |
title_short | Modeling of mitral chordae’s length in echocardiography as a function of their manual measurement in the operating room |
title_sort | modeling of mitral chordae’s length in echocardiography as a function of their manual measurement in the operating room |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8981775/ https://www.ncbi.nlm.nih.gov/pubmed/35379261 http://dx.doi.org/10.1186/s13019-022-01816-8 |
work_keys_str_mv | AT gunmesut modelingofmitralchordaeslengthinechocardiographyasafunctionoftheirmanualmeasurementintheoperatingroom AT barrymisbaou modelingofmitralchordaeslengthinechocardiographyasafunctionoftheirmanualmeasurementintheoperatingroom AT bohbotyohann modelingofmitralchordaeslengthinechocardiographyasafunctionoftheirmanualmeasurementintheoperatingroom AT tribouilloychristophe modelingofmitralchordaeslengthinechocardiographyasafunctionoftheirmanualmeasurementintheoperatingroom AT touatigilles modelingofmitralchordaeslengthinechocardiographyasafunctionoftheirmanualmeasurementintheoperatingroom |