Cargando…

Comparison of the third-generation streamlined liner of the pharynx airway (SLIPA-3G) with the laryngeal mask airway supreme for laparoscopic cholecystectomy: a randomized prospective study

BACKGROUND: The third-generation streamlined liner of the pharynx airway (SLIPA-3G) is a new-generation supraglottic airway device (SAD) that is non-cuffed and disposable, with a sealing pressure that varies dynamically with the airway pressure. This study compared the SLIPA-3G with the laryngeal ma...

Descripción completa

Detalles Bibliográficos
Autores principales: Fan, Hongna, Li, Lin, Zhu, Lei, Yi, Zhuo, Diao, Yugang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8981837/
https://www.ncbi.nlm.nih.gov/pubmed/35382763
http://dx.doi.org/10.1186/s12871-022-01638-0
_version_ 1784681683861110784
author Fan, Hongna
Li, Lin
Zhu, Lei
Yi, Zhuo
Diao, Yugang
author_facet Fan, Hongna
Li, Lin
Zhu, Lei
Yi, Zhuo
Diao, Yugang
author_sort Fan, Hongna
collection PubMed
description BACKGROUND: The third-generation streamlined liner of the pharynx airway (SLIPA-3G) is a new-generation supraglottic airway device (SAD) that is non-cuffed and disposable, with a sealing pressure that varies dynamically with the airway pressure. This study compared the SLIPA-3G with the laryngeal mask airway supreme (LMAS) in patients undergoing laparoscopic cholecystectomy. METHODS: Two hundred and twenty patients scheduled for laparoscopic cholecystectomy were randomly allocated to either the SLIPA-3G group or the LMAS group. Data were collected on the patients’ hemodynamic parameters at different time points, ease of insertion, fiberoptic view, oropharyngeal leak pressure (OLP) at different time points and SAD-related complications. RESULTS: The mean OLP immediately after device placement in the LMAS group was significantly higher than that of the SLIPA-3G group (31.34 ± 6.99 cmH(2)O vs.28.94 ± 6.01 cmH(2)O, P = 0.008, 95% CI 0.62–4.17). The OLPs of the two groups were not significantly different after the induction of a pneumoperitoneum until the end of surgery. The OLP increased gradually through the course of the operation in the SLIPA-3G group (P value = 0.035) but not in the LMAS group (P value = 0.945). There was no significant difference between the two groups in hemodynamic parameters, insertion time and success rate, fiberoptic view and complication rate. CONCLUSIONS: The SLIPA-3G and LMAS were associated with comparable OLPs, hemodynamic parameters, ease of insertion, fiberoptic views and complication rates when used during laparoscopic cholecystectomy. The SLIPA-3G can be used as an effective alternative to the LMAS in patients undergoing laparoscopic surgeries.
format Online
Article
Text
id pubmed-8981837
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-89818372022-04-06 Comparison of the third-generation streamlined liner of the pharynx airway (SLIPA-3G) with the laryngeal mask airway supreme for laparoscopic cholecystectomy: a randomized prospective study Fan, Hongna Li, Lin Zhu, Lei Yi, Zhuo Diao, Yugang BMC Anesthesiol Research BACKGROUND: The third-generation streamlined liner of the pharynx airway (SLIPA-3G) is a new-generation supraglottic airway device (SAD) that is non-cuffed and disposable, with a sealing pressure that varies dynamically with the airway pressure. This study compared the SLIPA-3G with the laryngeal mask airway supreme (LMAS) in patients undergoing laparoscopic cholecystectomy. METHODS: Two hundred and twenty patients scheduled for laparoscopic cholecystectomy were randomly allocated to either the SLIPA-3G group or the LMAS group. Data were collected on the patients’ hemodynamic parameters at different time points, ease of insertion, fiberoptic view, oropharyngeal leak pressure (OLP) at different time points and SAD-related complications. RESULTS: The mean OLP immediately after device placement in the LMAS group was significantly higher than that of the SLIPA-3G group (31.34 ± 6.99 cmH(2)O vs.28.94 ± 6.01 cmH(2)O, P = 0.008, 95% CI 0.62–4.17). The OLPs of the two groups were not significantly different after the induction of a pneumoperitoneum until the end of surgery. The OLP increased gradually through the course of the operation in the SLIPA-3G group (P value = 0.035) but not in the LMAS group (P value = 0.945). There was no significant difference between the two groups in hemodynamic parameters, insertion time and success rate, fiberoptic view and complication rate. CONCLUSIONS: The SLIPA-3G and LMAS were associated with comparable OLPs, hemodynamic parameters, ease of insertion, fiberoptic views and complication rates when used during laparoscopic cholecystectomy. The SLIPA-3G can be used as an effective alternative to the LMAS in patients undergoing laparoscopic surgeries. BioMed Central 2022-04-05 /pmc/articles/PMC8981837/ /pubmed/35382763 http://dx.doi.org/10.1186/s12871-022-01638-0 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Fan, Hongna
Li, Lin
Zhu, Lei
Yi, Zhuo
Diao, Yugang
Comparison of the third-generation streamlined liner of the pharynx airway (SLIPA-3G) with the laryngeal mask airway supreme for laparoscopic cholecystectomy: a randomized prospective study
title Comparison of the third-generation streamlined liner of the pharynx airway (SLIPA-3G) with the laryngeal mask airway supreme for laparoscopic cholecystectomy: a randomized prospective study
title_full Comparison of the third-generation streamlined liner of the pharynx airway (SLIPA-3G) with the laryngeal mask airway supreme for laparoscopic cholecystectomy: a randomized prospective study
title_fullStr Comparison of the third-generation streamlined liner of the pharynx airway (SLIPA-3G) with the laryngeal mask airway supreme for laparoscopic cholecystectomy: a randomized prospective study
title_full_unstemmed Comparison of the third-generation streamlined liner of the pharynx airway (SLIPA-3G) with the laryngeal mask airway supreme for laparoscopic cholecystectomy: a randomized prospective study
title_short Comparison of the third-generation streamlined liner of the pharynx airway (SLIPA-3G) with the laryngeal mask airway supreme for laparoscopic cholecystectomy: a randomized prospective study
title_sort comparison of the third-generation streamlined liner of the pharynx airway (slipa-3g) with the laryngeal mask airway supreme for laparoscopic cholecystectomy: a randomized prospective study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8981837/
https://www.ncbi.nlm.nih.gov/pubmed/35382763
http://dx.doi.org/10.1186/s12871-022-01638-0
work_keys_str_mv AT fanhongna comparisonofthethirdgenerationstreamlinedlinerofthepharynxairwayslipa3gwiththelaryngealmaskairwaysupremeforlaparoscopiccholecystectomyarandomizedprospectivestudy
AT lilin comparisonofthethirdgenerationstreamlinedlinerofthepharynxairwayslipa3gwiththelaryngealmaskairwaysupremeforlaparoscopiccholecystectomyarandomizedprospectivestudy
AT zhulei comparisonofthethirdgenerationstreamlinedlinerofthepharynxairwayslipa3gwiththelaryngealmaskairwaysupremeforlaparoscopiccholecystectomyarandomizedprospectivestudy
AT yizhuo comparisonofthethirdgenerationstreamlinedlinerofthepharynxairwayslipa3gwiththelaryngealmaskairwaysupremeforlaparoscopiccholecystectomyarandomizedprospectivestudy
AT diaoyugang comparisonofthethirdgenerationstreamlinedlinerofthepharynxairwayslipa3gwiththelaryngealmaskairwaysupremeforlaparoscopiccholecystectomyarandomizedprospectivestudy