High-quality imaging of endolymphatic hydrops acquired in 7 minutes using sensitive hT(2)W–3D–FLAIR reconstructed with magnitude and zero-filled interpolation
BACKGROUND: It is still challenging to detect endolymphatic hydrops (EH) in patients with Meniere’s disease (MD) using MRI. The aim of the present study was to optimize a sensitive technique generating strong contrast enhancement from minimum gadolinium–diethylenetriamine pentaacetic acid (Gd–DTPA)...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8986670/ https://www.ncbi.nlm.nih.gov/pubmed/34145490 http://dx.doi.org/10.1007/s00405-021-06912-4 |
Sumario: | BACKGROUND: It is still challenging to detect endolymphatic hydrops (EH) in patients with Meniere’s disease (MD) using MRI. The aim of the present study was to optimize a sensitive technique generating strong contrast enhancement from minimum gadolinium–diethylenetriamine pentaacetic acid (Gd–DTPA) while reliably detecting EH in the inner ear, including the apex. MATERIALS AND METHODS: All imaging was performed using a 3.0 T MR system 24 h after intratympanic injection of low-dose Gd–DTPA. Heavily T2-weighted 3-dimensional fluid-attenuated inversion recovery reconstructed with magnitude and zero-filled interpolation (hT(2)W–FLAIR–ZFI) was optimized and validated in phantom studies and compared with medium inversion time inversion recovery imaging with magnitude reconstruction (MIIRMR). The following parameters were used in hT(2)W–FLAIR–ZFI: repetition time 14,000 ms, echo time 663 ms, inversion time 2900 ms, flip angle 120°, echo train length 271, and field of view 166 × 196 mm(2). RESULTS: MRI obtained using hT(2)W–FLAIR–MZFI yielded high-quality images with sharper and smoother borders between the endolymph and perilymph and a higher signal intensity ratio and more homogenous perilymph enhancement than those generated with MIIRMR (p < 0.01). There were predominantly grade II EHs in the cochleae and grade III EHs in the vestibule in definite MD. EH was detected in the apex of 11/16 ipsilateral ears, 3/16 contralateral ears in unilateral definite MD and 3/6 ears in bilateral MD. CONCLUSIONS: The novel hT(2)W–FLAIR–MZFI technique is sensitive and demonstrates strong and homogenous enhancement by minimum Gd–DTPA in the inner ear, including the apex, and yields high-quality images with sharp borders between the endolymph and perilymph. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00405-021-06912-4. |
---|