Cargando…
Fire Intumescent, High-Temperature Resistant, Mechanically Flexible Graphene Oxide Network for Exceptional Fire Shielding and Ultra-Fast Fire Warning
Smart fire alarm sensor (FAS) materials with mechanically robust, excellent flame retardancy as well as ultra-sensitive temperature-responsive capability are highly attractive platforms for fire safety application. However, most reported FAS materials can hardly provide sensitive, continuous and rel...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Nature Singapore
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8986961/ https://www.ncbi.nlm.nih.gov/pubmed/35384618 http://dx.doi.org/10.1007/s40820-022-00837-1 |
_version_ | 1784682631597654016 |
---|---|
author | Cao, Cheng-Fei Yu, Bin Chen, Zuan-Yu Qu, Yong-Xiang Li, Yu-Tong Shi, Yong-Qian Ma, Zhe-Wen Sun, Feng-Na Pan, Qing-Hua Tang, Long-Cheng Song, Pingan Wang, Hao |
author_facet | Cao, Cheng-Fei Yu, Bin Chen, Zuan-Yu Qu, Yong-Xiang Li, Yu-Tong Shi, Yong-Qian Ma, Zhe-Wen Sun, Feng-Na Pan, Qing-Hua Tang, Long-Cheng Song, Pingan Wang, Hao |
author_sort | Cao, Cheng-Fei |
collection | PubMed |
description | Smart fire alarm sensor (FAS) materials with mechanically robust, excellent flame retardancy as well as ultra-sensitive temperature-responsive capability are highly attractive platforms for fire safety application. However, most reported FAS materials can hardly provide sensitive, continuous and reliable alarm signal output due to their undesirable temperature-responsive, flame-resistant and mechanical performances. To overcome these hurdles, herein, we utilize the multi-amino molecule, named HCPA, that can serve as triple-roles including cross-linker, fire retardant and reducing agent for decorating graphene oxide (GO) sheets and obtaining the GO/HCPA hybrid networks. Benefiting from the formation of multi-interactions in hybrid network, the optimized GO/HCPA network exhibits significant increment in mechanical strength, e.g., tensile strength and toughness increase of ~ 2.3 and ~ 5.7 times, respectively, compared to the control one. More importantly, based on P and N doping and promoting thermal reduction effect on GO network, the excellent flame retardancy (withstanding ~ 1200 °C flame attack), ultra-fast fire alarm response time (~ 0.6 s) and ultra-long alarming period (> 600 s) are obtained, representing the best comprehensive performance of GO-based FAS counterparts. Furthermore, based on GO/HCPA network, the fireproof coating is constructed and applied in polymer foam and exhibited exceptional fire shielding performance. This work provides a new idea for designing and fabricating desirable FAS materials and fireproof coatings. [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s40820-022-00837-1. |
format | Online Article Text |
id | pubmed-8986961 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer Nature Singapore |
record_format | MEDLINE/PubMed |
spelling | pubmed-89869612022-04-22 Fire Intumescent, High-Temperature Resistant, Mechanically Flexible Graphene Oxide Network for Exceptional Fire Shielding and Ultra-Fast Fire Warning Cao, Cheng-Fei Yu, Bin Chen, Zuan-Yu Qu, Yong-Xiang Li, Yu-Tong Shi, Yong-Qian Ma, Zhe-Wen Sun, Feng-Na Pan, Qing-Hua Tang, Long-Cheng Song, Pingan Wang, Hao Nanomicro Lett Article Smart fire alarm sensor (FAS) materials with mechanically robust, excellent flame retardancy as well as ultra-sensitive temperature-responsive capability are highly attractive platforms for fire safety application. However, most reported FAS materials can hardly provide sensitive, continuous and reliable alarm signal output due to their undesirable temperature-responsive, flame-resistant and mechanical performances. To overcome these hurdles, herein, we utilize the multi-amino molecule, named HCPA, that can serve as triple-roles including cross-linker, fire retardant and reducing agent for decorating graphene oxide (GO) sheets and obtaining the GO/HCPA hybrid networks. Benefiting from the formation of multi-interactions in hybrid network, the optimized GO/HCPA network exhibits significant increment in mechanical strength, e.g., tensile strength and toughness increase of ~ 2.3 and ~ 5.7 times, respectively, compared to the control one. More importantly, based on P and N doping and promoting thermal reduction effect on GO network, the excellent flame retardancy (withstanding ~ 1200 °C flame attack), ultra-fast fire alarm response time (~ 0.6 s) and ultra-long alarming period (> 600 s) are obtained, representing the best comprehensive performance of GO-based FAS counterparts. Furthermore, based on GO/HCPA network, the fireproof coating is constructed and applied in polymer foam and exhibited exceptional fire shielding performance. This work provides a new idea for designing and fabricating desirable FAS materials and fireproof coatings. [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s40820-022-00837-1. Springer Nature Singapore 2022-04-06 /pmc/articles/PMC8986961/ /pubmed/35384618 http://dx.doi.org/10.1007/s40820-022-00837-1 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Cao, Cheng-Fei Yu, Bin Chen, Zuan-Yu Qu, Yong-Xiang Li, Yu-Tong Shi, Yong-Qian Ma, Zhe-Wen Sun, Feng-Na Pan, Qing-Hua Tang, Long-Cheng Song, Pingan Wang, Hao Fire Intumescent, High-Temperature Resistant, Mechanically Flexible Graphene Oxide Network for Exceptional Fire Shielding and Ultra-Fast Fire Warning |
title | Fire Intumescent, High-Temperature Resistant, Mechanically Flexible Graphene Oxide Network for Exceptional Fire Shielding and Ultra-Fast Fire Warning |
title_full | Fire Intumescent, High-Temperature Resistant, Mechanically Flexible Graphene Oxide Network for Exceptional Fire Shielding and Ultra-Fast Fire Warning |
title_fullStr | Fire Intumescent, High-Temperature Resistant, Mechanically Flexible Graphene Oxide Network for Exceptional Fire Shielding and Ultra-Fast Fire Warning |
title_full_unstemmed | Fire Intumescent, High-Temperature Resistant, Mechanically Flexible Graphene Oxide Network for Exceptional Fire Shielding and Ultra-Fast Fire Warning |
title_short | Fire Intumescent, High-Temperature Resistant, Mechanically Flexible Graphene Oxide Network for Exceptional Fire Shielding and Ultra-Fast Fire Warning |
title_sort | fire intumescent, high-temperature resistant, mechanically flexible graphene oxide network for exceptional fire shielding and ultra-fast fire warning |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8986961/ https://www.ncbi.nlm.nih.gov/pubmed/35384618 http://dx.doi.org/10.1007/s40820-022-00837-1 |
work_keys_str_mv | AT caochengfei fireintumescenthightemperatureresistantmechanicallyflexiblegrapheneoxidenetworkforexceptionalfireshieldingandultrafastfirewarning AT yubin fireintumescenthightemperatureresistantmechanicallyflexiblegrapheneoxidenetworkforexceptionalfireshieldingandultrafastfirewarning AT chenzuanyu fireintumescenthightemperatureresistantmechanicallyflexiblegrapheneoxidenetworkforexceptionalfireshieldingandultrafastfirewarning AT quyongxiang fireintumescenthightemperatureresistantmechanicallyflexiblegrapheneoxidenetworkforexceptionalfireshieldingandultrafastfirewarning AT liyutong fireintumescenthightemperatureresistantmechanicallyflexiblegrapheneoxidenetworkforexceptionalfireshieldingandultrafastfirewarning AT shiyongqian fireintumescenthightemperatureresistantmechanicallyflexiblegrapheneoxidenetworkforexceptionalfireshieldingandultrafastfirewarning AT mazhewen fireintumescenthightemperatureresistantmechanicallyflexiblegrapheneoxidenetworkforexceptionalfireshieldingandultrafastfirewarning AT sunfengna fireintumescenthightemperatureresistantmechanicallyflexiblegrapheneoxidenetworkforexceptionalfireshieldingandultrafastfirewarning AT panqinghua fireintumescenthightemperatureresistantmechanicallyflexiblegrapheneoxidenetworkforexceptionalfireshieldingandultrafastfirewarning AT tanglongcheng fireintumescenthightemperatureresistantmechanicallyflexiblegrapheneoxidenetworkforexceptionalfireshieldingandultrafastfirewarning AT songpingan fireintumescenthightemperatureresistantmechanicallyflexiblegrapheneoxidenetworkforexceptionalfireshieldingandultrafastfirewarning AT wanghao fireintumescenthightemperatureresistantmechanicallyflexiblegrapheneoxidenetworkforexceptionalfireshieldingandultrafastfirewarning |