Cargando…

Characterizing factors influencing calibration and optical property determination in quantitative reflectance spectroscopy to improve standardization

SIGNIFICANCE: The combination of reflectance and fluorescence spectroscopy allows the determination of tissue optical properties and the calculation of the intrinsic fluorescence in vivo. These parameters can discriminate between tissues and may allow the discrimination of malignant from benign tiss...

Descripción completa

Detalles Bibliográficos
Autores principales: Schmidt, Iris, Nagengast, Wouter B., Robinson, Dominic J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Society of Photo-Optical Instrumentation Engineers 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8988964/
https://www.ncbi.nlm.nih.gov/pubmed/35393792
http://dx.doi.org/10.1117/1.JBO.27.7.074714
_version_ 1784683069684318208
author Schmidt, Iris
Nagengast, Wouter B.
Robinson, Dominic J.
author_facet Schmidt, Iris
Nagengast, Wouter B.
Robinson, Dominic J.
author_sort Schmidt, Iris
collection PubMed
description SIGNIFICANCE: The combination of reflectance and fluorescence spectroscopy allows the determination of tissue optical properties and the calculation of the intrinsic fluorescence in vivo. These parameters can discriminate between tissues and may allow the discrimination of malignant from benign tissue. While this approach has significant clinical potential, the lack of standardization and quality assessment prevents the upscaling of research. AIM: Investigate which factors influence device calibration and tissue optical property determination. Improve system quality assessment and allow upscaling of the clinical research using multidiameter single fiber reflectance/singe fiber fluorescence spectroscopy. APPROACH: Two studies, one phantom based on uniform calibrations and skin measurements and a clinical study including clinical calibrations. The first validates the effect of factors under identical conditions and the effect of calibration quality on the optical property determination of skin. The second shows the effect of different system configurations and the performance of the system and probe over an extended period. RESULTS: Phantom calibrations showed stability over a period of 20 weeks except for a 16-week-old intralipid phantom which showed a significant difference (at least [Formula: see text]) for all five probes evaluated. For clinical calibrations, only the fiber tree had a significant influence (probe 4: [Formula: see text] and probe 5: [Formula: see text]) on the calibration quality. Interestingly, no degradation of probe performance was detected over a period of 21 months despite the exposure to stress during clinical measurements. Calibration quality affected [Formula: see text] and the power law scattering exponent, but the degree of the influence was different per fiber. CONCLUSIONS: Intralipid phantom quality and fiber tree performance are the main factors influencing the calibration quality. Probe and user performance did not show any effect, which makes the upscaling of research to multicenter trials easier. A high-quality assessment procedure should be implemented to track changes during clinical trials.
format Online
Article
Text
id pubmed-8988964
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Society of Photo-Optical Instrumentation Engineers
record_format MEDLINE/PubMed
spelling pubmed-89889642022-04-19 Characterizing factors influencing calibration and optical property determination in quantitative reflectance spectroscopy to improve standardization Schmidt, Iris Nagengast, Wouter B. Robinson, Dominic J. J Biomed Opt Special Section on Tissue Phantoms to Advance Biomedical Optical Systems SIGNIFICANCE: The combination of reflectance and fluorescence spectroscopy allows the determination of tissue optical properties and the calculation of the intrinsic fluorescence in vivo. These parameters can discriminate between tissues and may allow the discrimination of malignant from benign tissue. While this approach has significant clinical potential, the lack of standardization and quality assessment prevents the upscaling of research. AIM: Investigate which factors influence device calibration and tissue optical property determination. Improve system quality assessment and allow upscaling of the clinical research using multidiameter single fiber reflectance/singe fiber fluorescence spectroscopy. APPROACH: Two studies, one phantom based on uniform calibrations and skin measurements and a clinical study including clinical calibrations. The first validates the effect of factors under identical conditions and the effect of calibration quality on the optical property determination of skin. The second shows the effect of different system configurations and the performance of the system and probe over an extended period. RESULTS: Phantom calibrations showed stability over a period of 20 weeks except for a 16-week-old intralipid phantom which showed a significant difference (at least [Formula: see text]) for all five probes evaluated. For clinical calibrations, only the fiber tree had a significant influence (probe 4: [Formula: see text] and probe 5: [Formula: see text]) on the calibration quality. Interestingly, no degradation of probe performance was detected over a period of 21 months despite the exposure to stress during clinical measurements. Calibration quality affected [Formula: see text] and the power law scattering exponent, but the degree of the influence was different per fiber. CONCLUSIONS: Intralipid phantom quality and fiber tree performance are the main factors influencing the calibration quality. Probe and user performance did not show any effect, which makes the upscaling of research to multicenter trials easier. A high-quality assessment procedure should be implemented to track changes during clinical trials. Society of Photo-Optical Instrumentation Engineers 2022-04-07 2022-07 /pmc/articles/PMC8988964/ /pubmed/35393792 http://dx.doi.org/10.1117/1.JBO.27.7.074714 Text en © 2022 The Authors https://creativecommons.org/licenses/by/4.0/Published by SPIE under a Creative Commons Attribution 4.0 International License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
spellingShingle Special Section on Tissue Phantoms to Advance Biomedical Optical Systems
Schmidt, Iris
Nagengast, Wouter B.
Robinson, Dominic J.
Characterizing factors influencing calibration and optical property determination in quantitative reflectance spectroscopy to improve standardization
title Characterizing factors influencing calibration and optical property determination in quantitative reflectance spectroscopy to improve standardization
title_full Characterizing factors influencing calibration and optical property determination in quantitative reflectance spectroscopy to improve standardization
title_fullStr Characterizing factors influencing calibration and optical property determination in quantitative reflectance spectroscopy to improve standardization
title_full_unstemmed Characterizing factors influencing calibration and optical property determination in quantitative reflectance spectroscopy to improve standardization
title_short Characterizing factors influencing calibration and optical property determination in quantitative reflectance spectroscopy to improve standardization
title_sort characterizing factors influencing calibration and optical property determination in quantitative reflectance spectroscopy to improve standardization
topic Special Section on Tissue Phantoms to Advance Biomedical Optical Systems
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8988964/
https://www.ncbi.nlm.nih.gov/pubmed/35393792
http://dx.doi.org/10.1117/1.JBO.27.7.074714
work_keys_str_mv AT schmidtiris characterizingfactorsinfluencingcalibrationandopticalpropertydeterminationinquantitativereflectancespectroscopytoimprovestandardization
AT nagengastwouterb characterizingfactorsinfluencingcalibrationandopticalpropertydeterminationinquantitativereflectancespectroscopytoimprovestandardization
AT robinsondominicj characterizingfactorsinfluencingcalibrationandopticalpropertydeterminationinquantitativereflectancespectroscopytoimprovestandardization