Contactless Monitoring of Breathing Pattern and Thoracoabdominal Asynchronies in Preterm Infants Using Depth Cameras: A Feasibility Study

Objective: Monitoring infants’ breathing activity is crucial in research and clinical applications but remains a challenge. This study aims to develop a contactless method to monitor breathing patterns and thoracoabdominal asynchronies in infants inside the incubator, using depth cameras. Methods: W...

Descripción completa

Detalles Bibliográficos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: IEEE 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8989160/
https://www.ncbi.nlm.nih.gov/pubmed/35415022
http://dx.doi.org/10.1109/JTEHM.2022.3159997
_version_ 1784683106366652416
collection PubMed
description Objective: Monitoring infants’ breathing activity is crucial in research and clinical applications but remains a challenge. This study aims to develop a contactless method to monitor breathing patterns and thoracoabdominal asynchronies in infants inside the incubator, using depth cameras. Methods: We proposed an algorithm to extract the 3D displacements of the ribcage and abdomen from the analysis of depth images. We evaluated the accuracy of the system in-vitro vs. a reference motion capture analyzer. We also conducted a feasibility study on 12 patients receiving non-invasive respiratory support to estimate the mean and the variability of the chest wall displacements in preterm infants and evaluate the suitability of the proposed system in the clinical setting. Results: In-vitro, the mean (95% CI) error in the measurement of amplitude, frequency and phase shift between compartmental displacements was −0.14 (−0.57, 0.28) mm, 0.02 (−0.99, 1.03) bpm, and −0.40 (−1.76, 0.95)°, respectively. In-vivo, the mean (95% CI) amplitude of the ribcage and abdomen displacements were 0.99 (0.34, 2.67) mm and 1.20 (0.40, 2.15) mm, respectively. Conclusions: The developed system proved accurate in-vitro and was suitable for the clinical environment. Clinical Impact: The proposed method has value for evaluating infants’ breathing patterns in research applications and, after further development, may represent a simple monitoring tool for infants’ respiratory activity inside the incubator.
format Online
Article
Text
id pubmed-8989160
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher IEEE
record_format MEDLINE/PubMed
spelling pubmed-89891602022-04-11 Contactless Monitoring of Breathing Pattern and Thoracoabdominal Asynchronies in Preterm Infants Using Depth Cameras: A Feasibility Study IEEE J Transl Eng Health Med Article Objective: Monitoring infants’ breathing activity is crucial in research and clinical applications but remains a challenge. This study aims to develop a contactless method to monitor breathing patterns and thoracoabdominal asynchronies in infants inside the incubator, using depth cameras. Methods: We proposed an algorithm to extract the 3D displacements of the ribcage and abdomen from the analysis of depth images. We evaluated the accuracy of the system in-vitro vs. a reference motion capture analyzer. We also conducted a feasibility study on 12 patients receiving non-invasive respiratory support to estimate the mean and the variability of the chest wall displacements in preterm infants and evaluate the suitability of the proposed system in the clinical setting. Results: In-vitro, the mean (95% CI) error in the measurement of amplitude, frequency and phase shift between compartmental displacements was −0.14 (−0.57, 0.28) mm, 0.02 (−0.99, 1.03) bpm, and −0.40 (−1.76, 0.95)°, respectively. In-vivo, the mean (95% CI) amplitude of the ribcage and abdomen displacements were 0.99 (0.34, 2.67) mm and 1.20 (0.40, 2.15) mm, respectively. Conclusions: The developed system proved accurate in-vitro and was suitable for the clinical environment. Clinical Impact: The proposed method has value for evaluating infants’ breathing patterns in research applications and, after further development, may represent a simple monitoring tool for infants’ respiratory activity inside the incubator. IEEE 2022-03-21 /pmc/articles/PMC8989160/ /pubmed/35415022 http://dx.doi.org/10.1109/JTEHM.2022.3159997 Text en https://creativecommons.org/licenses/by/4.0/This work is licensed under a Creative Commons Attribution 4.0 License. For more information, see https://creativecommons.org/licenses/by/4.0/
spellingShingle Article
Contactless Monitoring of Breathing Pattern and Thoracoabdominal Asynchronies in Preterm Infants Using Depth Cameras: A Feasibility Study
title Contactless Monitoring of Breathing Pattern and Thoracoabdominal Asynchronies in Preterm Infants Using Depth Cameras: A Feasibility Study
title_full Contactless Monitoring of Breathing Pattern and Thoracoabdominal Asynchronies in Preterm Infants Using Depth Cameras: A Feasibility Study
title_fullStr Contactless Monitoring of Breathing Pattern and Thoracoabdominal Asynchronies in Preterm Infants Using Depth Cameras: A Feasibility Study
title_full_unstemmed Contactless Monitoring of Breathing Pattern and Thoracoabdominal Asynchronies in Preterm Infants Using Depth Cameras: A Feasibility Study
title_short Contactless Monitoring of Breathing Pattern and Thoracoabdominal Asynchronies in Preterm Infants Using Depth Cameras: A Feasibility Study
title_sort contactless monitoring of breathing pattern and thoracoabdominal asynchronies in preterm infants using depth cameras: a feasibility study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8989160/
https://www.ncbi.nlm.nih.gov/pubmed/35415022
http://dx.doi.org/10.1109/JTEHM.2022.3159997
work_keys_str_mv AT contactlessmonitoringofbreathingpatternandthoracoabdominalasynchroniesinpreterminfantsusingdepthcamerasafeasibilitystudy
AT contactlessmonitoringofbreathingpatternandthoracoabdominalasynchroniesinpreterminfantsusingdepthcamerasafeasibilitystudy
AT contactlessmonitoringofbreathingpatternandthoracoabdominalasynchroniesinpreterminfantsusingdepthcamerasafeasibilitystudy
AT contactlessmonitoringofbreathingpatternandthoracoabdominalasynchroniesinpreterminfantsusingdepthcamerasafeasibilitystudy
AT contactlessmonitoringofbreathingpatternandthoracoabdominalasynchroniesinpreterminfantsusingdepthcamerasafeasibilitystudy
AT contactlessmonitoringofbreathingpatternandthoracoabdominalasynchroniesinpreterminfantsusingdepthcamerasafeasibilitystudy