Cargando…

Lab-in-a-van: Rapid SARS-CoV-2 testing response with a mobile laboratory

BACKGROUND: High testing rates and rapid contact tracing have been key interventions to control COVID-19 in Victoria, Australia. A mobile laboratory (LabVan), for rapid SARS-CoV-2 diagnostics, was deployed at sites deemed critical by the Victorian State Department of Health as part of the response....

Descripción completa

Detalles Bibliográficos
Autores principales: Ballard, Susan A, Graham, Maryza, David, Debra, Hoang, Tuyet, Donald, Angela, Sait, Michelle, Isles, Nicole, Matlock, Amelia, Yallop, Sarah, Bek, Mark, Howden, Benjamin P, Stinear, Timothy P
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8989475/
https://www.ncbi.nlm.nih.gov/pubmed/35405388
http://dx.doi.org/10.1016/j.ebiom.2022.103983
Descripción
Sumario:BACKGROUND: High testing rates and rapid contact tracing have been key interventions to control COVID-19 in Victoria, Australia. A mobile laboratory (LabVan), for rapid SARS-CoV-2 diagnostics, was deployed at sites deemed critical by the Victorian State Department of Health as part of the response. We describe the process of design, implementation, and performance benchmarked against a central reference laboratory. METHODS: A BSL2 compliant laboratory, complete with a class II biological safety cabinet, was built within a Mercedes-Benz Sprinter Panel Van. Swabs were collected by on-site collection teams, registered using mobile internet-enabled tablets and tested using the Xpert® Xpress SARS-CoV-2 assay. Results were reported remotely via HL7 messaging to Public Health Units. Patients with negative results were automatically notified by mobile telephone text messaging (SMS). FINDINGS: A pilot trial of the LabVan identified a median turnaround time (TAT) from collection to reporting of 1:19 h:mm (IQR 0:18, Range 1:03–18:32) compared to 9:40 h:mm (IQR 8:46, Range 6:51–19:30) for standard processing within the central laboratory. During deployment in nine rural and urban COVID-19 outbreaks the median TAT was 2:18 h:mm (IQR 1:18, Range 0:50–16:52) compared to 19:08 h:mm (IQR 5:49, Range 1:36–58:52) for samples submitted to the central laboratory. No quality control issues were identified in the LabVan. INTERPRETATION: The LabVan is an ISO15189 compliant testing facility fully operationalized for mobile point-of-care testing that significantly reduces TAT for result reporting, facilitating rapid public health actions. FUNDING: This work was supported by the Department of Health, Victoria State Government, Australia.