Cargando…

Upward Shifts in the Internal Representation of Frequency Can Persist Over a 3-Year Period for Cochlear Implant Patients Fit With a Relatively Short Electrode Array

Patients fit with cochlear implants (CIs) commonly indicate at the time of device fitting and for some time after, that the speech signal sounds abnormal. A high pitch or timbre is one component of the abnormal percept. In this project, our aim was to determine whether a number of years of CI use re...

Descripción completa

Detalles Bibliográficos
Autores principales: Dorman, Michael F., Natale, Sarah C., Noble, Jack H., Zeitler, Daniel M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8990937/
https://www.ncbi.nlm.nih.gov/pubmed/35399353
http://dx.doi.org/10.3389/fnhum.2022.863891
_version_ 1784683484941385728
author Dorman, Michael F.
Natale, Sarah C.
Noble, Jack H.
Zeitler, Daniel M.
author_facet Dorman, Michael F.
Natale, Sarah C.
Noble, Jack H.
Zeitler, Daniel M.
author_sort Dorman, Michael F.
collection PubMed
description Patients fit with cochlear implants (CIs) commonly indicate at the time of device fitting and for some time after, that the speech signal sounds abnormal. A high pitch or timbre is one component of the abnormal percept. In this project, our aim was to determine whether a number of years of CI use reduced perceived upshifts in frequency spectrum and/or voice fundamental frequency. The participants were five individuals who were deaf in one ear and who had normal hearing in the other ear. The deafened ears had been implanted with a 18.5 mm electrode array which resulted in signal input frequencies being directed to locations in the spiral ganglion (SG) that were between one and two octaves higher than the input frequencies. The patients judged the similarity of a clean signal (a male-voice sentence) presented to their implanted ear and candidate, implant-like, signals presented to their normal-hearing (NH) ear. Matches to implant sound quality were obtained, on average, at 8 months after device activation (see section “Time 1”) and at 35 months after activation (see section “Time 2”). At Time 1, the matches to CI sound quality were characterized, most generally, by upshifts in the frequency spectrum and in voice pitch. At Time 2, for four of the five patients, frequency spectrum values remained elevated. For all five patients F0 values remained elevated. Overall, the data offer little support for the proposition that, for patients fit with shorter electrode arrays, cortical plasticity nudges the cortical representation of the CI voice toward more normal, or less upshifted, frequency values between 8 and 35 months after device activation. Cortical plasticity may be limited when there are large differences between frequencies in the input signal and the locations in the SG stimulated by those frequencies.
format Online
Article
Text
id pubmed-8990937
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-89909372022-04-09 Upward Shifts in the Internal Representation of Frequency Can Persist Over a 3-Year Period for Cochlear Implant Patients Fit With a Relatively Short Electrode Array Dorman, Michael F. Natale, Sarah C. Noble, Jack H. Zeitler, Daniel M. Front Hum Neurosci Neuroscience Patients fit with cochlear implants (CIs) commonly indicate at the time of device fitting and for some time after, that the speech signal sounds abnormal. A high pitch or timbre is one component of the abnormal percept. In this project, our aim was to determine whether a number of years of CI use reduced perceived upshifts in frequency spectrum and/or voice fundamental frequency. The participants were five individuals who were deaf in one ear and who had normal hearing in the other ear. The deafened ears had been implanted with a 18.5 mm electrode array which resulted in signal input frequencies being directed to locations in the spiral ganglion (SG) that were between one and two octaves higher than the input frequencies. The patients judged the similarity of a clean signal (a male-voice sentence) presented to their implanted ear and candidate, implant-like, signals presented to their normal-hearing (NH) ear. Matches to implant sound quality were obtained, on average, at 8 months after device activation (see section “Time 1”) and at 35 months after activation (see section “Time 2”). At Time 1, the matches to CI sound quality were characterized, most generally, by upshifts in the frequency spectrum and in voice pitch. At Time 2, for four of the five patients, frequency spectrum values remained elevated. For all five patients F0 values remained elevated. Overall, the data offer little support for the proposition that, for patients fit with shorter electrode arrays, cortical plasticity nudges the cortical representation of the CI voice toward more normal, or less upshifted, frequency values between 8 and 35 months after device activation. Cortical plasticity may be limited when there are large differences between frequencies in the input signal and the locations in the SG stimulated by those frequencies. Frontiers Media S.A. 2022-03-25 /pmc/articles/PMC8990937/ /pubmed/35399353 http://dx.doi.org/10.3389/fnhum.2022.863891 Text en Copyright © 2022 Dorman, Natale, Noble and Zeitler. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neuroscience
Dorman, Michael F.
Natale, Sarah C.
Noble, Jack H.
Zeitler, Daniel M.
Upward Shifts in the Internal Representation of Frequency Can Persist Over a 3-Year Period for Cochlear Implant Patients Fit With a Relatively Short Electrode Array
title Upward Shifts in the Internal Representation of Frequency Can Persist Over a 3-Year Period for Cochlear Implant Patients Fit With a Relatively Short Electrode Array
title_full Upward Shifts in the Internal Representation of Frequency Can Persist Over a 3-Year Period for Cochlear Implant Patients Fit With a Relatively Short Electrode Array
title_fullStr Upward Shifts in the Internal Representation of Frequency Can Persist Over a 3-Year Period for Cochlear Implant Patients Fit With a Relatively Short Electrode Array
title_full_unstemmed Upward Shifts in the Internal Representation of Frequency Can Persist Over a 3-Year Period for Cochlear Implant Patients Fit With a Relatively Short Electrode Array
title_short Upward Shifts in the Internal Representation of Frequency Can Persist Over a 3-Year Period for Cochlear Implant Patients Fit With a Relatively Short Electrode Array
title_sort upward shifts in the internal representation of frequency can persist over a 3-year period for cochlear implant patients fit with a relatively short electrode array
topic Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8990937/
https://www.ncbi.nlm.nih.gov/pubmed/35399353
http://dx.doi.org/10.3389/fnhum.2022.863891
work_keys_str_mv AT dormanmichaelf upwardshiftsintheinternalrepresentationoffrequencycanpersistovera3yearperiodforcochlearimplantpatientsfitwitharelativelyshortelectrodearray
AT natalesarahc upwardshiftsintheinternalrepresentationoffrequencycanpersistovera3yearperiodforcochlearimplantpatientsfitwitharelativelyshortelectrodearray
AT noblejackh upwardshiftsintheinternalrepresentationoffrequencycanpersistovera3yearperiodforcochlearimplantpatientsfitwitharelativelyshortelectrodearray
AT zeitlerdanielm upwardshiftsintheinternalrepresentationoffrequencycanpersistovera3yearperiodforcochlearimplantpatientsfitwitharelativelyshortelectrodearray