Cargando…
Changes in Nerve Conduction Studies After Distal Radius Fracture Fixation Using a Volar Approach and Locked Plate
PURPOSE: To determine whether there are changes in nerve conduction studies (NCS) of the median nerve after distal radius fracture (DRF) and to determine how operative fixation through a volar approach with a locking plate contributes to nerve conduction changes. We hypothesized that a considerable...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8991506/ https://www.ncbi.nlm.nih.gov/pubmed/35415514 http://dx.doi.org/10.1016/j.jhsg.2020.06.003 |
Sumario: | PURPOSE: To determine whether there are changes in nerve conduction studies (NCS) of the median nerve after distal radius fracture (DRF) and to determine how operative fixation through a volar approach with a locking plate contributes to nerve conduction changes. We hypothesized that a considerable percentage of patients would have electrodiagnostic evidence of median neuropathy at the wrist after fracture, but fixation with a volar locked plate would not worsen the electrodiagnostic findings. METHODS: This was a prospective cohort study of 14 neurologically asymptomatic patients who underwent surgical treatment of an isolated DRF using a volar plate. All patients underwent surgery within 2 weeks of injury. On the day of surgery and at the 6-week follow-up, patients were clinically examined, Quick–Disabilities of the Arm, Shoulder, and Hand questionnaire was completed, and patients underwent NCS using a handheld device with the unaffected limb, which was used as a comparison. Preoperative and postoperative nerve function were compared with the unaffected limb as a baseline. RESULTS: Patients without symptoms after DRF had a 28% incidence of prolonged latencies compared with reference values for the device used. Distal sensory latencies of the median nerve were 3.64 ± 0.32 ms in the unaffected arm, 3.76 ± 0.70 ms before surgery, and 3.81 ± 0.52 ms after surgery. Distal motor latencies of the median nerve were 3.91 ± 0.59, 3.60 ± 0.68, and 3.88 ± 0.36 ms in respective arms and time points. Quick–Disabilities of the Arm, Shoulder, and Hand scores improved from 77 before surgery to 46 at 6 weeks. CONCLUSIONS: Asymptomatic patients may satisfy nerve conduction criteria for median neuropathy at the wrist after DRF; however, open reduction and treatment with a volar locked plate has no significant effect on NCS findings. TYPE OF STUDY/LEVEL OF EVIDENCE: Prognostic II. |
---|