Cargando…

Proposal for a Method to Measure the Range of Dart-Throwing Motion

PURPOSE: To examine the reliability of a novel technique to measure the range of the dart-throwing motion. METHODS: Two raters measured the range of the dart-throwing motion in 40 healthy subjects. For the measurement, subjects were asked to perform a simulated hammering motion using various experim...

Descripción completa

Detalles Bibliográficos
Autores principales: Mitsukane, Masahiro, Sugama, Kosuke, Suzuki, Yusuke, Tanabe, Hirohumi, Tsurumi, Takahiko
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8991534/
https://www.ncbi.nlm.nih.gov/pubmed/35415508
http://dx.doi.org/10.1016/j.jhsg.2020.04.004
_version_ 1784683588602560512
author Mitsukane, Masahiro
Sugama, Kosuke
Suzuki, Yusuke
Tanabe, Hirohumi
Tsurumi, Takahiko
author_facet Mitsukane, Masahiro
Sugama, Kosuke
Suzuki, Yusuke
Tanabe, Hirohumi
Tsurumi, Takahiko
author_sort Mitsukane, Masahiro
collection PubMed
description PURPOSE: To examine the reliability of a novel technique to measure the range of the dart-throwing motion. METHODS: Two raters measured the range of the dart-throwing motion in 40 healthy subjects. For the measurement, subjects were asked to perform a simulated hammering motion using various experimental tools (a real hammer, a thick wooden rod, and a thin wooden rod). The inclination angle of the tool in the vertical plane was measured with a manual goniometer at the maximal position of radial extension and ulnar flexion. The sum of these angles was defined as the range of the dart-throwing motion. To evaluate relative interrater reliability, intraclass correlation coefficients were calculated. To account for absolute reliability, Bland-Altman analysis was performed. RESULTS: Intraclass correlation coefficients ranged 0.72 to 0.86. Bland-Altman analysis revealed that some systematic errors existed when the measurement was carried out with the real hammer or the thin rod, but not the thick rod. The 95% confidence intervals of minimal detectable change for the thick rod were 36.0° and 35.8° for the dominant and nondominant sides, respectively. Measured values between the experimental tools were similar. CONCLUSIONS: Relative reliability was shown to be good or moderate for each set of measurements. Some refinements are required to reduce measurement error. Accuracy of measurement should also be confirmed. CLINICAL RELEVANCE: No standardized methods for measuring the range of the dart-throwing motion have yet been established. Our technique can be performed rapidly and with easily available materials, producing reliable measurements for the range of the dart-throwing motion.
format Online
Article
Text
id pubmed-8991534
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-89915342022-04-11 Proposal for a Method to Measure the Range of Dart-Throwing Motion Mitsukane, Masahiro Sugama, Kosuke Suzuki, Yusuke Tanabe, Hirohumi Tsurumi, Takahiko J Hand Surg Glob Online Original Research PURPOSE: To examine the reliability of a novel technique to measure the range of the dart-throwing motion. METHODS: Two raters measured the range of the dart-throwing motion in 40 healthy subjects. For the measurement, subjects were asked to perform a simulated hammering motion using various experimental tools (a real hammer, a thick wooden rod, and a thin wooden rod). The inclination angle of the tool in the vertical plane was measured with a manual goniometer at the maximal position of radial extension and ulnar flexion. The sum of these angles was defined as the range of the dart-throwing motion. To evaluate relative interrater reliability, intraclass correlation coefficients were calculated. To account for absolute reliability, Bland-Altman analysis was performed. RESULTS: Intraclass correlation coefficients ranged 0.72 to 0.86. Bland-Altman analysis revealed that some systematic errors existed when the measurement was carried out with the real hammer or the thin rod, but not the thick rod. The 95% confidence intervals of minimal detectable change for the thick rod were 36.0° and 35.8° for the dominant and nondominant sides, respectively. Measured values between the experimental tools were similar. CONCLUSIONS: Relative reliability was shown to be good or moderate for each set of measurements. Some refinements are required to reduce measurement error. Accuracy of measurement should also be confirmed. CLINICAL RELEVANCE: No standardized methods for measuring the range of the dart-throwing motion have yet been established. Our technique can be performed rapidly and with easily available materials, producing reliable measurements for the range of the dart-throwing motion. Elsevier 2020-05-12 /pmc/articles/PMC8991534/ /pubmed/35415508 http://dx.doi.org/10.1016/j.jhsg.2020.04.004 Text en © 2020 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research
Mitsukane, Masahiro
Sugama, Kosuke
Suzuki, Yusuke
Tanabe, Hirohumi
Tsurumi, Takahiko
Proposal for a Method to Measure the Range of Dart-Throwing Motion
title Proposal for a Method to Measure the Range of Dart-Throwing Motion
title_full Proposal for a Method to Measure the Range of Dart-Throwing Motion
title_fullStr Proposal for a Method to Measure the Range of Dart-Throwing Motion
title_full_unstemmed Proposal for a Method to Measure the Range of Dart-Throwing Motion
title_short Proposal for a Method to Measure the Range of Dart-Throwing Motion
title_sort proposal for a method to measure the range of dart-throwing motion
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8991534/
https://www.ncbi.nlm.nih.gov/pubmed/35415508
http://dx.doi.org/10.1016/j.jhsg.2020.04.004
work_keys_str_mv AT mitsukanemasahiro proposalforamethodtomeasuretherangeofdartthrowingmotion
AT sugamakosuke proposalforamethodtomeasuretherangeofdartthrowingmotion
AT suzukiyusuke proposalforamethodtomeasuretherangeofdartthrowingmotion
AT tanabehirohumi proposalforamethodtomeasuretherangeofdartthrowingmotion
AT tsurumitakahiko proposalforamethodtomeasuretherangeofdartthrowingmotion