Cargando…

Rapid identification of Amanita citrinoannulata poisoning using colorimetric and real-time fluorescence and loop-mediated isothermal amplification (LAMP) based on the nuclear ITS region

Health concerns and financial losses caused by mushroom poisoning have been reported worldwide. Amanita citrinoannulata, a poisonous mushroom commonly found in China, results in a toxic reaction in humans after mistaken ingestion. To reduce the mistaken ingestion of poisonous mushrooms and to improv...

Descripción completa

Detalles Bibliográficos
Autores principales: Gao, Jie, Xie, Ruibin, Wang, Nan, Zhang, Juan, Sun, Xiaoyun, Wang, Hongjing, Tan, Jianxin, Chen, Ailiang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8991603/
https://www.ncbi.nlm.nih.gov/pubmed/35415685
http://dx.doi.org/10.1016/j.fochms.2022.100082
_version_ 1784683603523796992
author Gao, Jie
Xie, Ruibin
Wang, Nan
Zhang, Juan
Sun, Xiaoyun
Wang, Hongjing
Tan, Jianxin
Chen, Ailiang
author_facet Gao, Jie
Xie, Ruibin
Wang, Nan
Zhang, Juan
Sun, Xiaoyun
Wang, Hongjing
Tan, Jianxin
Chen, Ailiang
author_sort Gao, Jie
collection PubMed
description Health concerns and financial losses caused by mushroom poisoning have been reported worldwide. Amanita citrinoannulata, a poisonous mushroom commonly found in China, results in a toxic reaction in humans after mistaken ingestion. To reduce the mistaken ingestion of poisonous mushrooms and to improve clinical diagnosis of mushroom poisoning, a rapid mushroom species identification method is required. Such identification methods could be advantageous in the identification of other poisonous mushroom species. This study developed two rapid and sensitive methods for the detection of A. citrinoannulata utilizing colorimetric and real-time loop-mediated isothermal amplification (LAMP) technology and specifically designed primers for the internal transcribed spacer (ITS) genes of A. citrinoannulata. The methods demonstrated high sensitivity as 0.2 ng of A. citrinoannulata DNA could be detected, with no cross-reaction with 41 non-target mushroom species. The entire detection process could be completed within 40 min without requiring complex instruments and can be observed by the naked eye. Therefore, these novel methods can be used for the identification of fresh and cooked mushroom samples and vomit samples, which contain only 1% A. citrinoannulata. Furthermore, these methods facilitate the detection of mushroom poisoning, and thus, have potential to reduce the number of mushroom poisoning-related deaths worldwide.
format Online
Article
Text
id pubmed-8991603
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-89916032022-04-11 Rapid identification of Amanita citrinoannulata poisoning using colorimetric and real-time fluorescence and loop-mediated isothermal amplification (LAMP) based on the nuclear ITS region Gao, Jie Xie, Ruibin Wang, Nan Zhang, Juan Sun, Xiaoyun Wang, Hongjing Tan, Jianxin Chen, Ailiang Food Chem (Oxf) Research Article Health concerns and financial losses caused by mushroom poisoning have been reported worldwide. Amanita citrinoannulata, a poisonous mushroom commonly found in China, results in a toxic reaction in humans after mistaken ingestion. To reduce the mistaken ingestion of poisonous mushrooms and to improve clinical diagnosis of mushroom poisoning, a rapid mushroom species identification method is required. Such identification methods could be advantageous in the identification of other poisonous mushroom species. This study developed two rapid and sensitive methods for the detection of A. citrinoannulata utilizing colorimetric and real-time loop-mediated isothermal amplification (LAMP) technology and specifically designed primers for the internal transcribed spacer (ITS) genes of A. citrinoannulata. The methods demonstrated high sensitivity as 0.2 ng of A. citrinoannulata DNA could be detected, with no cross-reaction with 41 non-target mushroom species. The entire detection process could be completed within 40 min without requiring complex instruments and can be observed by the naked eye. Therefore, these novel methods can be used for the identification of fresh and cooked mushroom samples and vomit samples, which contain only 1% A. citrinoannulata. Furthermore, these methods facilitate the detection of mushroom poisoning, and thus, have potential to reduce the number of mushroom poisoning-related deaths worldwide. Elsevier 2022-02-04 /pmc/articles/PMC8991603/ /pubmed/35415685 http://dx.doi.org/10.1016/j.fochms.2022.100082 Text en © 2022 The Authors https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Research Article
Gao, Jie
Xie, Ruibin
Wang, Nan
Zhang, Juan
Sun, Xiaoyun
Wang, Hongjing
Tan, Jianxin
Chen, Ailiang
Rapid identification of Amanita citrinoannulata poisoning using colorimetric and real-time fluorescence and loop-mediated isothermal amplification (LAMP) based on the nuclear ITS region
title Rapid identification of Amanita citrinoannulata poisoning using colorimetric and real-time fluorescence and loop-mediated isothermal amplification (LAMP) based on the nuclear ITS region
title_full Rapid identification of Amanita citrinoannulata poisoning using colorimetric and real-time fluorescence and loop-mediated isothermal amplification (LAMP) based on the nuclear ITS region
title_fullStr Rapid identification of Amanita citrinoannulata poisoning using colorimetric and real-time fluorescence and loop-mediated isothermal amplification (LAMP) based on the nuclear ITS region
title_full_unstemmed Rapid identification of Amanita citrinoannulata poisoning using colorimetric and real-time fluorescence and loop-mediated isothermal amplification (LAMP) based on the nuclear ITS region
title_short Rapid identification of Amanita citrinoannulata poisoning using colorimetric and real-time fluorescence and loop-mediated isothermal amplification (LAMP) based on the nuclear ITS region
title_sort rapid identification of amanita citrinoannulata poisoning using colorimetric and real-time fluorescence and loop-mediated isothermal amplification (lamp) based on the nuclear its region
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8991603/
https://www.ncbi.nlm.nih.gov/pubmed/35415685
http://dx.doi.org/10.1016/j.fochms.2022.100082
work_keys_str_mv AT gaojie rapididentificationofamanitacitrinoannulatapoisoningusingcolorimetricandrealtimefluorescenceandloopmediatedisothermalamplificationlampbasedonthenuclearitsregion
AT xieruibin rapididentificationofamanitacitrinoannulatapoisoningusingcolorimetricandrealtimefluorescenceandloopmediatedisothermalamplificationlampbasedonthenuclearitsregion
AT wangnan rapididentificationofamanitacitrinoannulatapoisoningusingcolorimetricandrealtimefluorescenceandloopmediatedisothermalamplificationlampbasedonthenuclearitsregion
AT zhangjuan rapididentificationofamanitacitrinoannulatapoisoningusingcolorimetricandrealtimefluorescenceandloopmediatedisothermalamplificationlampbasedonthenuclearitsregion
AT sunxiaoyun rapididentificationofamanitacitrinoannulatapoisoningusingcolorimetricandrealtimefluorescenceandloopmediatedisothermalamplificationlampbasedonthenuclearitsregion
AT wanghongjing rapididentificationofamanitacitrinoannulatapoisoningusingcolorimetricandrealtimefluorescenceandloopmediatedisothermalamplificationlampbasedonthenuclearitsregion
AT tanjianxin rapididentificationofamanitacitrinoannulatapoisoningusingcolorimetricandrealtimefluorescenceandloopmediatedisothermalamplificationlampbasedonthenuclearitsregion
AT chenailiang rapididentificationofamanitacitrinoannulatapoisoningusingcolorimetricandrealtimefluorescenceandloopmediatedisothermalamplificationlampbasedonthenuclearitsregion