Cargando…

Effect of total body irradiation lung block parameters on lung doses using three‐dimensional dosimetry

PURPOSE: Total body irradiation (TBI) is an integral part of stem cell transplant. However, patients are at risk of treatment‐related toxicities, including radiation pneumonitis. While lung dose is one of the most crucial aspects of TBI dosimetry, currently available data are based on point doses. A...

Descripción completa

Detalles Bibliográficos
Autores principales: Luk, Samuel M. H., Wallner, Kent, Glenn, Mallory C., Ermoian, Ralph, Phillips, Mark H., Tseng, Yolanda D., Kim, Minsun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8992940/
https://www.ncbi.nlm.nih.gov/pubmed/34985180
http://dx.doi.org/10.1002/acm2.13513
_version_ 1784683808278183936
author Luk, Samuel M. H.
Wallner, Kent
Glenn, Mallory C.
Ermoian, Ralph
Phillips, Mark H.
Tseng, Yolanda D.
Kim, Minsun
author_facet Luk, Samuel M. H.
Wallner, Kent
Glenn, Mallory C.
Ermoian, Ralph
Phillips, Mark H.
Tseng, Yolanda D.
Kim, Minsun
author_sort Luk, Samuel M. H.
collection PubMed
description PURPOSE: Total body irradiation (TBI) is an integral part of stem cell transplant. However, patients are at risk of treatment‐related toxicities, including radiation pneumonitis. While lung dose is one of the most crucial aspects of TBI dosimetry, currently available data are based on point doses. As volumetric dose distribution could be substantially altered by lung block parameters, we used 3D dosimetry in our treatment planning system to estimate volumetric lung dose and measure the impact of various lung block designs. MATERIALS AND METHODS: We commissioned a TBI beam model in RayStation that matches the measured tissue‐phantom ratio under our clinical TBI setup. Cerrobend blocks were automatically generated in RayStation on thoracic Computed Tomography (CT) scans from three anonymized patients using the lung, clavicle, spine, and diaphragmatic contours. The margin for block edge was varied to 0, 1, or 2 cm from the superior, lateral, and inferior thoracic borders, with a uniform margin 2.5 cm lateral to the vertebral bodies. The lung dose was calculated and compared with a prescription dose of 1200 cGy in six fractions (three with blocks and three without). RESULT: The point dose at midplane under the block and the average lung dose are at the range of 73%–76% and 80%–88% of prescription dose respectively regardless of the block margins. In contrast, the percent lung volume receiving 10 Gy increased by nearly two‐fold, from 31% to 60% over the margins from 0 to 2 cm. CONCLUSIONS: The TPS‐derived 3D lung dose is substantially different from the nominal dose assumed with HVL lung blocks. Point doses under the block are insufficient to accurately gauge the relationship between dose and pneumonitis, and TBI dosimetry could be highly variable between patients and institutions as more descriptive parameters are not included in protocols. Much progress remains to be made to optimize and standardize technical aspects of TBI, and better dosimetry could provide more precise dosimetric predictors for pneumonitis risk.
format Online
Article
Text
id pubmed-8992940
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-89929402022-04-13 Effect of total body irradiation lung block parameters on lung doses using three‐dimensional dosimetry Luk, Samuel M. H. Wallner, Kent Glenn, Mallory C. Ermoian, Ralph Phillips, Mark H. Tseng, Yolanda D. Kim, Minsun J Appl Clin Med Phys Technical Notes PURPOSE: Total body irradiation (TBI) is an integral part of stem cell transplant. However, patients are at risk of treatment‐related toxicities, including radiation pneumonitis. While lung dose is one of the most crucial aspects of TBI dosimetry, currently available data are based on point doses. As volumetric dose distribution could be substantially altered by lung block parameters, we used 3D dosimetry in our treatment planning system to estimate volumetric lung dose and measure the impact of various lung block designs. MATERIALS AND METHODS: We commissioned a TBI beam model in RayStation that matches the measured tissue‐phantom ratio under our clinical TBI setup. Cerrobend blocks were automatically generated in RayStation on thoracic Computed Tomography (CT) scans from three anonymized patients using the lung, clavicle, spine, and diaphragmatic contours. The margin for block edge was varied to 0, 1, or 2 cm from the superior, lateral, and inferior thoracic borders, with a uniform margin 2.5 cm lateral to the vertebral bodies. The lung dose was calculated and compared with a prescription dose of 1200 cGy in six fractions (three with blocks and three without). RESULT: The point dose at midplane under the block and the average lung dose are at the range of 73%–76% and 80%–88% of prescription dose respectively regardless of the block margins. In contrast, the percent lung volume receiving 10 Gy increased by nearly two‐fold, from 31% to 60% over the margins from 0 to 2 cm. CONCLUSIONS: The TPS‐derived 3D lung dose is substantially different from the nominal dose assumed with HVL lung blocks. Point doses under the block are insufficient to accurately gauge the relationship between dose and pneumonitis, and TBI dosimetry could be highly variable between patients and institutions as more descriptive parameters are not included in protocols. Much progress remains to be made to optimize and standardize technical aspects of TBI, and better dosimetry could provide more precise dosimetric predictors for pneumonitis risk. John Wiley and Sons Inc. 2022-01-05 /pmc/articles/PMC8992940/ /pubmed/34985180 http://dx.doi.org/10.1002/acm2.13513 Text en © 2022 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, LLC on behalf of The American Association of Physicists in Medicine https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Notes
Luk, Samuel M. H.
Wallner, Kent
Glenn, Mallory C.
Ermoian, Ralph
Phillips, Mark H.
Tseng, Yolanda D.
Kim, Minsun
Effect of total body irradiation lung block parameters on lung doses using three‐dimensional dosimetry
title Effect of total body irradiation lung block parameters on lung doses using three‐dimensional dosimetry
title_full Effect of total body irradiation lung block parameters on lung doses using three‐dimensional dosimetry
title_fullStr Effect of total body irradiation lung block parameters on lung doses using three‐dimensional dosimetry
title_full_unstemmed Effect of total body irradiation lung block parameters on lung doses using three‐dimensional dosimetry
title_short Effect of total body irradiation lung block parameters on lung doses using three‐dimensional dosimetry
title_sort effect of total body irradiation lung block parameters on lung doses using three‐dimensional dosimetry
topic Technical Notes
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8992940/
https://www.ncbi.nlm.nih.gov/pubmed/34985180
http://dx.doi.org/10.1002/acm2.13513
work_keys_str_mv AT luksamuelmh effectoftotalbodyirradiationlungblockparametersonlungdosesusingthreedimensionaldosimetry
AT wallnerkent effectoftotalbodyirradiationlungblockparametersonlungdosesusingthreedimensionaldosimetry
AT glennmalloryc effectoftotalbodyirradiationlungblockparametersonlungdosesusingthreedimensionaldosimetry
AT ermoianralph effectoftotalbodyirradiationlungblockparametersonlungdosesusingthreedimensionaldosimetry
AT phillipsmarkh effectoftotalbodyirradiationlungblockparametersonlungdosesusingthreedimensionaldosimetry
AT tsengyolandad effectoftotalbodyirradiationlungblockparametersonlungdosesusingthreedimensionaldosimetry
AT kimminsun effectoftotalbodyirradiationlungblockparametersonlungdosesusingthreedimensionaldosimetry