Cargando…

Evaluation of a cardiac troponin process flow at the chest pain center with the shortest turnaround time

BACKGROUND: Early diagnosis of myocardial infarction is crucial in chest pain management and cardiac troponin (cTn) test is an important step in it. Process improvement to shorten the test turnaround time (TAT) may improve patients’ outcomes. The cTn test at chest pain center (CPC) of Zhongshan Hosp...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Hao, Wang, Xinyue, Wang, Kouqiong, Duan, Xincen, Jiang, Wenhai, Tang, Bin, Pan, Baishen, Wang, Beili, Guo, Wei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8993626/
https://www.ncbi.nlm.nih.gov/pubmed/35263018
http://dx.doi.org/10.1002/jcla.24335
_version_ 1784683938124398592
author Wang, Hao
Wang, Xinyue
Wang, Kouqiong
Duan, Xincen
Jiang, Wenhai
Tang, Bin
Pan, Baishen
Wang, Beili
Guo, Wei
author_facet Wang, Hao
Wang, Xinyue
Wang, Kouqiong
Duan, Xincen
Jiang, Wenhai
Tang, Bin
Pan, Baishen
Wang, Beili
Guo, Wei
author_sort Wang, Hao
collection PubMed
description BACKGROUND: Early diagnosis of myocardial infarction is crucial in chest pain management and cardiac troponin (cTn) test is an important step in it. Process improvement to shorten the test turnaround time (TAT) may improve patients’ outcomes. The cTn test at chest pain center (CPC) of Zhongshan Hospital had the shortest TAT ever reported, but its process flow was not fully evaluated. METHODS: We performed a stepwise evaluation of CPC cTn TAT and explored the potential factor that might cause delay. The performance of CPC cTn test was also compared with cTn test and human chorionic gonadotropin (HCG) test ordered from emergency department (ED). RESULTS: At least 95% of CPC cTn tests were completed in 60 min, while 62% in 30 min. The medians of monthly order‐to‐collect time, collect‐to‐received time, and received‐to‐result time were ~7 min, ~3 min, and ~13 min, respectively. The samples collected at the bedside had longer collect‐to‐received time than the ones collected at the blood draw site next to the laboratory. Compared to ED cTn test and ED HCG test, CPC cTn test took less time in each step. A combination of the sample type switch and the centrifugation time reduction contributed the most to the shortening of TAT, which was reflected in the received‐to‐result time. CONCLUSIONS: The current process flow of CPC cTn test satisfied the requirements of chest pain management, giving an example of how to implement process improvement for emergency medicine to shorten TAT of laboratory tests.
format Online
Article
Text
id pubmed-8993626
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-89936262022-04-13 Evaluation of a cardiac troponin process flow at the chest pain center with the shortest turnaround time Wang, Hao Wang, Xinyue Wang, Kouqiong Duan, Xincen Jiang, Wenhai Tang, Bin Pan, Baishen Wang, Beili Guo, Wei J Clin Lab Anal Research Articles BACKGROUND: Early diagnosis of myocardial infarction is crucial in chest pain management and cardiac troponin (cTn) test is an important step in it. Process improvement to shorten the test turnaround time (TAT) may improve patients’ outcomes. The cTn test at chest pain center (CPC) of Zhongshan Hospital had the shortest TAT ever reported, but its process flow was not fully evaluated. METHODS: We performed a stepwise evaluation of CPC cTn TAT and explored the potential factor that might cause delay. The performance of CPC cTn test was also compared with cTn test and human chorionic gonadotropin (HCG) test ordered from emergency department (ED). RESULTS: At least 95% of CPC cTn tests were completed in 60 min, while 62% in 30 min. The medians of monthly order‐to‐collect time, collect‐to‐received time, and received‐to‐result time were ~7 min, ~3 min, and ~13 min, respectively. The samples collected at the bedside had longer collect‐to‐received time than the ones collected at the blood draw site next to the laboratory. Compared to ED cTn test and ED HCG test, CPC cTn test took less time in each step. A combination of the sample type switch and the centrifugation time reduction contributed the most to the shortening of TAT, which was reflected in the received‐to‐result time. CONCLUSIONS: The current process flow of CPC cTn test satisfied the requirements of chest pain management, giving an example of how to implement process improvement for emergency medicine to shorten TAT of laboratory tests. John Wiley and Sons Inc. 2022-03-09 /pmc/articles/PMC8993626/ /pubmed/35263018 http://dx.doi.org/10.1002/jcla.24335 Text en © 2022 The Authors. Journal of Clinical Laboratory Analysis published by Wiley Periodicals LLC. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Research Articles
Wang, Hao
Wang, Xinyue
Wang, Kouqiong
Duan, Xincen
Jiang, Wenhai
Tang, Bin
Pan, Baishen
Wang, Beili
Guo, Wei
Evaluation of a cardiac troponin process flow at the chest pain center with the shortest turnaround time
title Evaluation of a cardiac troponin process flow at the chest pain center with the shortest turnaround time
title_full Evaluation of a cardiac troponin process flow at the chest pain center with the shortest turnaround time
title_fullStr Evaluation of a cardiac troponin process flow at the chest pain center with the shortest turnaround time
title_full_unstemmed Evaluation of a cardiac troponin process flow at the chest pain center with the shortest turnaround time
title_short Evaluation of a cardiac troponin process flow at the chest pain center with the shortest turnaround time
title_sort evaluation of a cardiac troponin process flow at the chest pain center with the shortest turnaround time
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8993626/
https://www.ncbi.nlm.nih.gov/pubmed/35263018
http://dx.doi.org/10.1002/jcla.24335
work_keys_str_mv AT wanghao evaluationofacardiactroponinprocessflowatthechestpaincenterwiththeshortestturnaroundtime
AT wangxinyue evaluationofacardiactroponinprocessflowatthechestpaincenterwiththeshortestturnaroundtime
AT wangkouqiong evaluationofacardiactroponinprocessflowatthechestpaincenterwiththeshortestturnaroundtime
AT duanxincen evaluationofacardiactroponinprocessflowatthechestpaincenterwiththeshortestturnaroundtime
AT jiangwenhai evaluationofacardiactroponinprocessflowatthechestpaincenterwiththeshortestturnaroundtime
AT tangbin evaluationofacardiactroponinprocessflowatthechestpaincenterwiththeshortestturnaroundtime
AT panbaishen evaluationofacardiactroponinprocessflowatthechestpaincenterwiththeshortestturnaroundtime
AT wangbeili evaluationofacardiactroponinprocessflowatthechestpaincenterwiththeshortestturnaroundtime
AT guowei evaluationofacardiactroponinprocessflowatthechestpaincenterwiththeshortestturnaroundtime