Cargando…
Endoscopic ultrasound-guided side-fenestrated needle biopsy sampling is sensitive for pancreatic neuroendocrine tumors but inadequate for tumor grading: a prospective study
Accurate pretreatment grading of pancreatic neuroendocrine tumors (PanNETs) is important to guide patient management. We aimed to evaluate endoscopic ultrasound-guided fine needle biopsy sampling (EUS-FNB) for the preoperative diagnosis and grading of PanNETs. In a tertiary-center setting, patients...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8993931/ https://www.ncbi.nlm.nih.gov/pubmed/35396490 http://dx.doi.org/10.1038/s41598-022-09923-1 |
_version_ | 1784684009541861376 |
---|---|
author | Appelstrand, Alexander Bergstedt, Fredrik Elf, Anna-Karin Fagman, Henrik Hedenström, Per |
author_facet | Appelstrand, Alexander Bergstedt, Fredrik Elf, Anna-Karin Fagman, Henrik Hedenström, Per |
author_sort | Appelstrand, Alexander |
collection | PubMed |
description | Accurate pretreatment grading of pancreatic neuroendocrine tumors (PanNETs) is important to guide patient management. We aimed to evaluate endoscopic ultrasound-guided fine needle biopsy sampling (EUS-FNB) for the preoperative diagnosis and grading of PanNETs. In a tertiary-center setting, patients with suspected PanNETs were prospectively subjected to 22-gauge, reverse-bevel EUS-FNB. The EUS-FNB samples (Ki-67(EUS)) and corresponding surgical specimens (Ki-67(SURG)) were analyzed with Ki-67 indexing and thereafter tumor grading, (GRADE(EUS)) and (GRADE(SURG)) respectively. In total 52 PanNET-patients [median age: 66 years; females: 25/52; surgical resection 22/52 (42%)] were included. EUS-FNB was diagnostic in 44/52 (85%). In 42 available FNB-slides, the median neoplastic cell count was 1034 (IQR: 504–3667) with 32/42 (76%), 22/42 (52%), and 14/42 (33%) cases exceeding 500, 1000, and 2000 neoplastic cells respectively. Ki-67(SURG) was significantly higher compared to Ki-67(EUS) with a moderate correlation comparing Ki-67(EUS) and Ki-67(SURG) (Pearson r = 0.60, r(2) = 0.36, p = 0.011). The GRADE(EUS) had a weak level of agreement (κ = 0.08) compared with GRADE(SURG). Only 2/12 (17%) G2-tumors were correctly graded in EUS-FNB-samples. EUS-guided fine needle biopsy sampling is sensitive for preoperative diagnosis of PanNET but biopsy quality is relatively poor. Therefore, the approach seems suboptimal for pretreatment grading of PanNET. |
format | Online Article Text |
id | pubmed-8993931 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-89939312022-04-11 Endoscopic ultrasound-guided side-fenestrated needle biopsy sampling is sensitive for pancreatic neuroendocrine tumors but inadequate for tumor grading: a prospective study Appelstrand, Alexander Bergstedt, Fredrik Elf, Anna-Karin Fagman, Henrik Hedenström, Per Sci Rep Article Accurate pretreatment grading of pancreatic neuroendocrine tumors (PanNETs) is important to guide patient management. We aimed to evaluate endoscopic ultrasound-guided fine needle biopsy sampling (EUS-FNB) for the preoperative diagnosis and grading of PanNETs. In a tertiary-center setting, patients with suspected PanNETs were prospectively subjected to 22-gauge, reverse-bevel EUS-FNB. The EUS-FNB samples (Ki-67(EUS)) and corresponding surgical specimens (Ki-67(SURG)) were analyzed with Ki-67 indexing and thereafter tumor grading, (GRADE(EUS)) and (GRADE(SURG)) respectively. In total 52 PanNET-patients [median age: 66 years; females: 25/52; surgical resection 22/52 (42%)] were included. EUS-FNB was diagnostic in 44/52 (85%). In 42 available FNB-slides, the median neoplastic cell count was 1034 (IQR: 504–3667) with 32/42 (76%), 22/42 (52%), and 14/42 (33%) cases exceeding 500, 1000, and 2000 neoplastic cells respectively. Ki-67(SURG) was significantly higher compared to Ki-67(EUS) with a moderate correlation comparing Ki-67(EUS) and Ki-67(SURG) (Pearson r = 0.60, r(2) = 0.36, p = 0.011). The GRADE(EUS) had a weak level of agreement (κ = 0.08) compared with GRADE(SURG). Only 2/12 (17%) G2-tumors were correctly graded in EUS-FNB-samples. EUS-guided fine needle biopsy sampling is sensitive for preoperative diagnosis of PanNET but biopsy quality is relatively poor. Therefore, the approach seems suboptimal for pretreatment grading of PanNET. Nature Publishing Group UK 2022-04-08 /pmc/articles/PMC8993931/ /pubmed/35396490 http://dx.doi.org/10.1038/s41598-022-09923-1 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Appelstrand, Alexander Bergstedt, Fredrik Elf, Anna-Karin Fagman, Henrik Hedenström, Per Endoscopic ultrasound-guided side-fenestrated needle biopsy sampling is sensitive for pancreatic neuroendocrine tumors but inadequate for tumor grading: a prospective study |
title | Endoscopic ultrasound-guided side-fenestrated needle biopsy sampling is sensitive for pancreatic neuroendocrine tumors but inadequate for tumor grading: a prospective study |
title_full | Endoscopic ultrasound-guided side-fenestrated needle biopsy sampling is sensitive for pancreatic neuroendocrine tumors but inadequate for tumor grading: a prospective study |
title_fullStr | Endoscopic ultrasound-guided side-fenestrated needle biopsy sampling is sensitive for pancreatic neuroendocrine tumors but inadequate for tumor grading: a prospective study |
title_full_unstemmed | Endoscopic ultrasound-guided side-fenestrated needle biopsy sampling is sensitive for pancreatic neuroendocrine tumors but inadequate for tumor grading: a prospective study |
title_short | Endoscopic ultrasound-guided side-fenestrated needle biopsy sampling is sensitive for pancreatic neuroendocrine tumors but inadequate for tumor grading: a prospective study |
title_sort | endoscopic ultrasound-guided side-fenestrated needle biopsy sampling is sensitive for pancreatic neuroendocrine tumors but inadequate for tumor grading: a prospective study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8993931/ https://www.ncbi.nlm.nih.gov/pubmed/35396490 http://dx.doi.org/10.1038/s41598-022-09923-1 |
work_keys_str_mv | AT appelstrandalexander endoscopicultrasoundguidedsidefenestratedneedlebiopsysamplingissensitiveforpancreaticneuroendocrinetumorsbutinadequatefortumorgradingaprospectivestudy AT bergstedtfredrik endoscopicultrasoundguidedsidefenestratedneedlebiopsysamplingissensitiveforpancreaticneuroendocrinetumorsbutinadequatefortumorgradingaprospectivestudy AT elfannakarin endoscopicultrasoundguidedsidefenestratedneedlebiopsysamplingissensitiveforpancreaticneuroendocrinetumorsbutinadequatefortumorgradingaprospectivestudy AT fagmanhenrik endoscopicultrasoundguidedsidefenestratedneedlebiopsysamplingissensitiveforpancreaticneuroendocrinetumorsbutinadequatefortumorgradingaprospectivestudy AT hedenstromper endoscopicultrasoundguidedsidefenestratedneedlebiopsysamplingissensitiveforpancreaticneuroendocrinetumorsbutinadequatefortumorgradingaprospectivestudy |