Cargando…

Does closed-loop automated oxygen control reduce the duration of mechanical ventilation? A randomised controlled trial in ventilated preterm infants

BACKGROUND: Many preterm infants require supplemental oxygen in the newborn period but experience frequent fluctuations of their oxygen saturation levels. Intermittent episodes of hypoxia or hyperoxia increase the risk of complications. Compliance with achievement of oxygen saturation targets is var...

Descripción completa

Detalles Bibliográficos
Autores principales: Kaltsogianni, Ourania, Dassios, Theodore, Greenough, Anne
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8994422/
https://www.ncbi.nlm.nih.gov/pubmed/35395952
http://dx.doi.org/10.1186/s13063-022-06222-y
_version_ 1784684105472933888
author Kaltsogianni, Ourania
Dassios, Theodore
Greenough, Anne
author_facet Kaltsogianni, Ourania
Dassios, Theodore
Greenough, Anne
author_sort Kaltsogianni, Ourania
collection PubMed
description BACKGROUND: Many preterm infants require supplemental oxygen in the newborn period but experience frequent fluctuations of their oxygen saturation levels. Intermittent episodes of hypoxia or hyperoxia increase the risk of complications. Compliance with achievement of oxygen saturation targets is variable, and the need for frequent adjustments of the inspired oxygen concentration increases workload. Closed-loop automated oxygen control systems (CLAC) improve achievement of oxygen saturation targets and reduce both episodes of hypoxia and hyperoxia and the number of manual adjustments. This study investigates whether CLAC compared with manual oxygen control reduces the duration of mechanical ventilation in preterm infants born at less than 31 weeks of gestation. METHODS: This randomised controlled trial performed at a single tertiary neonatal unit is recruiting 70 infants born at less than 31 weeks of gestational age and within 48 h of initiation of mechanical ventilation. Infants are randomised to CLAC or manual oxygen control from recruitment until successful extubation. The primary outcome is the duration of mechanical ventilation, and secondary outcomes are the percentage of time spent within target oxygen saturation ranges, the time spent in hypoxia or hyperoxia, the number of manual adjustments required, the number of days on oxygen, the incidence of bronchopulmonary dysplasia and the length and cost of neonatal unit stay. The study is performed following informed parental consent and was approved by the Yorkshire and the Humber-Sheffield Research Ethics Committee (protocol version 1.1, 13 July 2021). DISCUSSION: This trial will investigate the effect of CLAC on the duration of mechanical ventilation, which is an important clinical outcome as prolonged mechanical ventilation is associated with important adverse outcomes, such as bronchopulmonary dysplasia. TRIAL REGISTRATION: ClinicalTrials.Gov NCT05030337. Registered on 17 August 2021 SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13063-022-06222-y.
format Online
Article
Text
id pubmed-8994422
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-89944222022-04-10 Does closed-loop automated oxygen control reduce the duration of mechanical ventilation? A randomised controlled trial in ventilated preterm infants Kaltsogianni, Ourania Dassios, Theodore Greenough, Anne Trials Study Protocol BACKGROUND: Many preterm infants require supplemental oxygen in the newborn period but experience frequent fluctuations of their oxygen saturation levels. Intermittent episodes of hypoxia or hyperoxia increase the risk of complications. Compliance with achievement of oxygen saturation targets is variable, and the need for frequent adjustments of the inspired oxygen concentration increases workload. Closed-loop automated oxygen control systems (CLAC) improve achievement of oxygen saturation targets and reduce both episodes of hypoxia and hyperoxia and the number of manual adjustments. This study investigates whether CLAC compared with manual oxygen control reduces the duration of mechanical ventilation in preterm infants born at less than 31 weeks of gestation. METHODS: This randomised controlled trial performed at a single tertiary neonatal unit is recruiting 70 infants born at less than 31 weeks of gestational age and within 48 h of initiation of mechanical ventilation. Infants are randomised to CLAC or manual oxygen control from recruitment until successful extubation. The primary outcome is the duration of mechanical ventilation, and secondary outcomes are the percentage of time spent within target oxygen saturation ranges, the time spent in hypoxia or hyperoxia, the number of manual adjustments required, the number of days on oxygen, the incidence of bronchopulmonary dysplasia and the length and cost of neonatal unit stay. The study is performed following informed parental consent and was approved by the Yorkshire and the Humber-Sheffield Research Ethics Committee (protocol version 1.1, 13 July 2021). DISCUSSION: This trial will investigate the effect of CLAC on the duration of mechanical ventilation, which is an important clinical outcome as prolonged mechanical ventilation is associated with important adverse outcomes, such as bronchopulmonary dysplasia. TRIAL REGISTRATION: ClinicalTrials.Gov NCT05030337. Registered on 17 August 2021 SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13063-022-06222-y. BioMed Central 2022-04-08 /pmc/articles/PMC8994422/ /pubmed/35395952 http://dx.doi.org/10.1186/s13063-022-06222-y Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Study Protocol
Kaltsogianni, Ourania
Dassios, Theodore
Greenough, Anne
Does closed-loop automated oxygen control reduce the duration of mechanical ventilation? A randomised controlled trial in ventilated preterm infants
title Does closed-loop automated oxygen control reduce the duration of mechanical ventilation? A randomised controlled trial in ventilated preterm infants
title_full Does closed-loop automated oxygen control reduce the duration of mechanical ventilation? A randomised controlled trial in ventilated preterm infants
title_fullStr Does closed-loop automated oxygen control reduce the duration of mechanical ventilation? A randomised controlled trial in ventilated preterm infants
title_full_unstemmed Does closed-loop automated oxygen control reduce the duration of mechanical ventilation? A randomised controlled trial in ventilated preterm infants
title_short Does closed-loop automated oxygen control reduce the duration of mechanical ventilation? A randomised controlled trial in ventilated preterm infants
title_sort does closed-loop automated oxygen control reduce the duration of mechanical ventilation? a randomised controlled trial in ventilated preterm infants
topic Study Protocol
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8994422/
https://www.ncbi.nlm.nih.gov/pubmed/35395952
http://dx.doi.org/10.1186/s13063-022-06222-y
work_keys_str_mv AT kaltsogianniourania doesclosedloopautomatedoxygencontrolreducethedurationofmechanicalventilationarandomisedcontrolledtrialinventilatedpreterminfants
AT dassiostheodore doesclosedloopautomatedoxygencontrolreducethedurationofmechanicalventilationarandomisedcontrolledtrialinventilatedpreterminfants
AT greenoughanne doesclosedloopautomatedoxygencontrolreducethedurationofmechanicalventilationarandomisedcontrolledtrialinventilatedpreterminfants