The Impact of Location and Device Coupling on the Performance of the Osia System Actuator

Active transcutaneous bone conduction (BC) devices offer the benefit of improved power output compared to passive transcutaneous devices and remove the risk of skin infections that are more common in traditional percutaneous BC devices. Despite these advantages, more research is needed on implant lo...

Descripción completa

Detalles Bibliográficos
Autores principales: Fierens, Guy, Borgers, Charlotte, Putzeys, Tristan, Walraevens, Joris, Van Wieringen, Astrid, Verhaert, Nicolas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8994691/
https://www.ncbi.nlm.nih.gov/pubmed/35411307
http://dx.doi.org/10.1155/2022/9079903
_version_ 1784684159324651520
author Fierens, Guy
Borgers, Charlotte
Putzeys, Tristan
Walraevens, Joris
Van Wieringen, Astrid
Verhaert, Nicolas
author_facet Fierens, Guy
Borgers, Charlotte
Putzeys, Tristan
Walraevens, Joris
Van Wieringen, Astrid
Verhaert, Nicolas
author_sort Fierens, Guy
collection PubMed
description Active transcutaneous bone conduction (BC) devices offer the benefit of improved power output compared to passive transcutaneous devices and remove the risk of skin infections that are more common in traditional percutaneous BC devices. Despite these advantages, more research is needed on implant location, device coupling, and their influence on device performance. This study is aimed at quantifying the extent to which certain parameters affect device output when using the Osia® system actuator. Parameters under study are (1) implant location, (2) comparison with the actuator of a state-of-the-art BC device, (3) bone undergrowth simulation, and (4) skull fixation. Five human cadaveric heads were implanted with the actuator at three different implant locations: (1) recommended, (2) posterior Osia® positions, and (3) standard Baha® position. At each location, the cochlear promontory velocity and the intracochlear pressure difference were measured. A percutaneous bone conduction actuator was used as a reference for the obtained measurements. Stimulation levels corresponded to a hearing level of 60 dB HL for frequencies between 250 and 6000 Hz. In addition, bone cement was used as a simulation for reactive bone growth. Results obtained in four heads indicate an improved power transmission of the transcutaneous actuator when implanted at the recommended position compared to the actuator of the percutaneous device on its respective recommended location when stimulating at an identical force level. A correlation was found between the promontory vibration and the actuator position, indicating that the same level of stimulation leads to higher promontory vibrations when the device is implanted closer to the ear canal. This is mainly reflected at frequencies higher than 1 kHz, where an increase was observed in both measurement modalities. At lower frequencies (<1 kHz), the power transmission is less influenced by the implant position and differences between the acquired responses are limited. In addition, when no rigid coupling to the skull is provided, power transfer losses of up to 30 dB can be expected.
format Online
Article
Text
id pubmed-8994691
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-89946912022-04-10 The Impact of Location and Device Coupling on the Performance of the Osia System Actuator Fierens, Guy Borgers, Charlotte Putzeys, Tristan Walraevens, Joris Van Wieringen, Astrid Verhaert, Nicolas Biomed Res Int Research Article Active transcutaneous bone conduction (BC) devices offer the benefit of improved power output compared to passive transcutaneous devices and remove the risk of skin infections that are more common in traditional percutaneous BC devices. Despite these advantages, more research is needed on implant location, device coupling, and their influence on device performance. This study is aimed at quantifying the extent to which certain parameters affect device output when using the Osia® system actuator. Parameters under study are (1) implant location, (2) comparison with the actuator of a state-of-the-art BC device, (3) bone undergrowth simulation, and (4) skull fixation. Five human cadaveric heads were implanted with the actuator at three different implant locations: (1) recommended, (2) posterior Osia® positions, and (3) standard Baha® position. At each location, the cochlear promontory velocity and the intracochlear pressure difference were measured. A percutaneous bone conduction actuator was used as a reference for the obtained measurements. Stimulation levels corresponded to a hearing level of 60 dB HL for frequencies between 250 and 6000 Hz. In addition, bone cement was used as a simulation for reactive bone growth. Results obtained in four heads indicate an improved power transmission of the transcutaneous actuator when implanted at the recommended position compared to the actuator of the percutaneous device on its respective recommended location when stimulating at an identical force level. A correlation was found between the promontory vibration and the actuator position, indicating that the same level of stimulation leads to higher promontory vibrations when the device is implanted closer to the ear canal. This is mainly reflected at frequencies higher than 1 kHz, where an increase was observed in both measurement modalities. At lower frequencies (<1 kHz), the power transmission is less influenced by the implant position and differences between the acquired responses are limited. In addition, when no rigid coupling to the skull is provided, power transfer losses of up to 30 dB can be expected. Hindawi 2022-04-02 /pmc/articles/PMC8994691/ /pubmed/35411307 http://dx.doi.org/10.1155/2022/9079903 Text en Copyright © 2022 Guy Fierens et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Fierens, Guy
Borgers, Charlotte
Putzeys, Tristan
Walraevens, Joris
Van Wieringen, Astrid
Verhaert, Nicolas
The Impact of Location and Device Coupling on the Performance of the Osia System Actuator
title The Impact of Location and Device Coupling on the Performance of the Osia System Actuator
title_full The Impact of Location and Device Coupling on the Performance of the Osia System Actuator
title_fullStr The Impact of Location and Device Coupling on the Performance of the Osia System Actuator
title_full_unstemmed The Impact of Location and Device Coupling on the Performance of the Osia System Actuator
title_short The Impact of Location and Device Coupling on the Performance of the Osia System Actuator
title_sort impact of location and device coupling on the performance of the osia system actuator
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8994691/
https://www.ncbi.nlm.nih.gov/pubmed/35411307
http://dx.doi.org/10.1155/2022/9079903
work_keys_str_mv AT fierensguy theimpactoflocationanddevicecouplingontheperformanceoftheosiasystemactuator
AT borgerscharlotte theimpactoflocationanddevicecouplingontheperformanceoftheosiasystemactuator
AT putzeystristan theimpactoflocationanddevicecouplingontheperformanceoftheosiasystemactuator
AT walraevensjoris theimpactoflocationanddevicecouplingontheperformanceoftheosiasystemactuator
AT vanwieringenastrid theimpactoflocationanddevicecouplingontheperformanceoftheosiasystemactuator
AT verhaertnicolas theimpactoflocationanddevicecouplingontheperformanceoftheosiasystemactuator
AT fierensguy impactoflocationanddevicecouplingontheperformanceoftheosiasystemactuator
AT borgerscharlotte impactoflocationanddevicecouplingontheperformanceoftheosiasystemactuator
AT putzeystristan impactoflocationanddevicecouplingontheperformanceoftheosiasystemactuator
AT walraevensjoris impactoflocationanddevicecouplingontheperformanceoftheosiasystemactuator
AT vanwieringenastrid impactoflocationanddevicecouplingontheperformanceoftheosiasystemactuator
AT verhaertnicolas impactoflocationanddevicecouplingontheperformanceoftheosiasystemactuator