Microbiological contamination of indoor and outdoor environments in a desert climate
Microbiological air contamination in the desert environment is becoming an essential subject for the health of office building occupants and public health. In this study, the concentrations and compositions of airborne microorganisms (bacteria and fungi) were assessed in indoor and outdoor environme...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8995910/ https://www.ncbi.nlm.nih.gov/pubmed/35403921 http://dx.doi.org/10.1007/s10661-022-10032-9 |
_version_ | 1784684385808678912 |
---|---|
author | Almatawah, Qadreyah A. Al-Rashidi, Mufaerh S. Yassin, Mohamed F. Varghese, Julie S. |
author_facet | Almatawah, Qadreyah A. Al-Rashidi, Mufaerh S. Yassin, Mohamed F. Varghese, Julie S. |
author_sort | Almatawah, Qadreyah A. |
collection | PubMed |
description | Microbiological air contamination in the desert environment is becoming an essential subject for the health of office building occupants and public health. In this study, the concentrations and compositions of airborne microorganisms (bacteria and fungi) were assessed in indoor and outdoor environments using a multistory building complex in Kuwait as a case study. Airborne microorganism samples were collected from 12 sites within the building complex containing nineteen stories over four seasons. Culturable airborne bacteria and fungi were impacted on selected media to determine their concentrations and compositions with a Biolog Omnilog GEN III system and Biolog MicroStation. The indoor mean airborne bacterial count concentrations ranged from 35 to 18,463 CFU/m(3), concentrations that are higher than 2,000 CFU/m(3), demonstrating high–very high contamination levels in all seasons. Fungal contamination was high in winter and summer, with detected concentrations > 2,000 CFU/m(3). Indoor-to-outdoor (I/O) ratios showed that airborne microbial contamination inside building floors originated from indoor air contamination. All the building floors showed bacterial and fungal concentrations ranging from less than 2,000 to more than 2,000 CFU/m(3), indicative of a high to very high air contamination level. Statistical analysis showed no correlation between bacterial and fungal concentrations, demonstrating that they originated from unrelated sources. In the indoor building air, the most prevalent bacterial isolate was Bacillus pseudomycoides/cereus, whereas the most dominant fungal isolate was Aspergillus spp. The low count for indoor air bacterial species suggested no particular health risk for the occupants. In contrast, the high count of indoor air fungal species in the winter samples and the presence of potentially allergenic genera detected may suggest possible health risks for the occupants. The results obtained are the basis for the recommendation that the maintenance activities of the HVAC system and the periodical cleaning operation program be revised and preplanned as protective measures. |
format | Online Article Text |
id | pubmed-8995910 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-89959102022-04-11 Microbiological contamination of indoor and outdoor environments in a desert climate Almatawah, Qadreyah A. Al-Rashidi, Mufaerh S. Yassin, Mohamed F. Varghese, Julie S. Environ Monit Assess Article Microbiological air contamination in the desert environment is becoming an essential subject for the health of office building occupants and public health. In this study, the concentrations and compositions of airborne microorganisms (bacteria and fungi) were assessed in indoor and outdoor environments using a multistory building complex in Kuwait as a case study. Airborne microorganism samples were collected from 12 sites within the building complex containing nineteen stories over four seasons. Culturable airborne bacteria and fungi were impacted on selected media to determine their concentrations and compositions with a Biolog Omnilog GEN III system and Biolog MicroStation. The indoor mean airborne bacterial count concentrations ranged from 35 to 18,463 CFU/m(3), concentrations that are higher than 2,000 CFU/m(3), demonstrating high–very high contamination levels in all seasons. Fungal contamination was high in winter and summer, with detected concentrations > 2,000 CFU/m(3). Indoor-to-outdoor (I/O) ratios showed that airborne microbial contamination inside building floors originated from indoor air contamination. All the building floors showed bacterial and fungal concentrations ranging from less than 2,000 to more than 2,000 CFU/m(3), indicative of a high to very high air contamination level. Statistical analysis showed no correlation between bacterial and fungal concentrations, demonstrating that they originated from unrelated sources. In the indoor building air, the most prevalent bacterial isolate was Bacillus pseudomycoides/cereus, whereas the most dominant fungal isolate was Aspergillus spp. The low count for indoor air bacterial species suggested no particular health risk for the occupants. In contrast, the high count of indoor air fungal species in the winter samples and the presence of potentially allergenic genera detected may suggest possible health risks for the occupants. The results obtained are the basis for the recommendation that the maintenance activities of the HVAC system and the periodical cleaning operation program be revised and preplanned as protective measures. Springer International Publishing 2022-04-11 2022 /pmc/articles/PMC8995910/ /pubmed/35403921 http://dx.doi.org/10.1007/s10661-022-10032-9 Text en © The Author(s), under exclusive licence to Springer Nature Switzerland AG 2022 This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic. |
spellingShingle | Article Almatawah, Qadreyah A. Al-Rashidi, Mufaerh S. Yassin, Mohamed F. Varghese, Julie S. Microbiological contamination of indoor and outdoor environments in a desert climate |
title | Microbiological contamination of indoor and outdoor environments in a desert climate |
title_full | Microbiological contamination of indoor and outdoor environments in a desert climate |
title_fullStr | Microbiological contamination of indoor and outdoor environments in a desert climate |
title_full_unstemmed | Microbiological contamination of indoor and outdoor environments in a desert climate |
title_short | Microbiological contamination of indoor and outdoor environments in a desert climate |
title_sort | microbiological contamination of indoor and outdoor environments in a desert climate |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8995910/ https://www.ncbi.nlm.nih.gov/pubmed/35403921 http://dx.doi.org/10.1007/s10661-022-10032-9 |
work_keys_str_mv | AT almatawahqadreyaha microbiologicalcontaminationofindoorandoutdoorenvironmentsinadesertclimate AT alrashidimufaerhs microbiologicalcontaminationofindoorandoutdoorenvironmentsinadesertclimate AT yassinmohamedf microbiologicalcontaminationofindoorandoutdoorenvironmentsinadesertclimate AT varghesejulies microbiologicalcontaminationofindoorandoutdoorenvironmentsinadesertclimate |