Cargando…

The Kocher-Langenbeck approach combined with robot-aided percutaneous anterior column screw fixation for transverse-oriented acetabular fractures: a retrospective study

OBJECTIVE: Transverse-oriented acetabular fractures (TOAFs), including transverse, transverse with posterior wall and T-shaped fractures, are always challenging for double-column reduction and fixation with minimally invasive method. The purpose of this study is to compare the therapeutic effects of...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Zhao-jie, Gu, Ya, Jia, Jian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8996653/
https://www.ncbi.nlm.nih.gov/pubmed/35410204
http://dx.doi.org/10.1186/s12891-022-05313-w
_version_ 1784684530309791744
author Liu, Zhao-jie
Gu, Ya
Jia, Jian
author_facet Liu, Zhao-jie
Gu, Ya
Jia, Jian
author_sort Liu, Zhao-jie
collection PubMed
description OBJECTIVE: Transverse-oriented acetabular fractures (TOAFs), including transverse, transverse with posterior wall and T-shaped fractures, are always challenging for double-column reduction and fixation with minimally invasive method. The purpose of this study is to compare the therapeutic effects of robot-aided percutaneous anterior column screw fixation versus minimally invasive anterior plate fixation for TOAFs based on the Kocher-Langenbeck (K-L) approach. METHODS: Patients suffering TOAFs that were fixed by robot-aided percutaneous anterior column screw fixation or minimally invasive anterior plate fixation associated with posterior fixation via the K-L approach were divided into two groups: group A (screw fixation) and group B (plate fixation). Surgical time, blood loss, incision length for anterior fixation and complications were recorded. Fracture reduction quality was evaluated using criteria described by Matta. Fracture healing was assessed on the series of pelvic radiographs at each follow-up. Functional outcomes were investigated using the modified Postel Merle D’Aubigne score at the final follow-up. RESULTS: Twenty-nine patients with TOAFs, including 12 patients in group A and 17 patients in group B, were evaluated for study eligibility. The mean surgical time of anterior fracture fixation was 18.7 ± 4.6 min in group A and 33.4 ± 5.0 min in group B (P < 0.001). The amount of intraoperative blood loss was 615.6 ± 178.7 ml in group A and 719.3 ± 199.0 ml in group B (P < 0.001). Incision length for anterior fixation was 9.0 ± 1.8 mm in group A and 81.2 ± 7.3 mm in group B (P < 0.001). The complications related to the surgery of anterior column only occurred in group B (lateral femoral cutaneous nerve palsy in 1 patient and groin discomfort in 1 patient). No significant differences in reduction quality, hospital stay, fracture healing time and functional results were noted between the two groups. CONCLUSION: The K-L approach combined with robot-aided anterior column screw fixation is a safe and effective option for TOAFs. Compared with minimally invasive anterior plate fixation, robot-aided screw fixation has obvious advantages on surgical time, blood loss, and invasiveness. The K-L approach combined with minimally invasive anterior plate fixation can also be a reliable alternative for TOAFs, with the similar reduction quality and functional results.
format Online
Article
Text
id pubmed-8996653
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-89966532022-04-12 The Kocher-Langenbeck approach combined with robot-aided percutaneous anterior column screw fixation for transverse-oriented acetabular fractures: a retrospective study Liu, Zhao-jie Gu, Ya Jia, Jian BMC Musculoskelet Disord Research OBJECTIVE: Transverse-oriented acetabular fractures (TOAFs), including transverse, transverse with posterior wall and T-shaped fractures, are always challenging for double-column reduction and fixation with minimally invasive method. The purpose of this study is to compare the therapeutic effects of robot-aided percutaneous anterior column screw fixation versus minimally invasive anterior plate fixation for TOAFs based on the Kocher-Langenbeck (K-L) approach. METHODS: Patients suffering TOAFs that were fixed by robot-aided percutaneous anterior column screw fixation or minimally invasive anterior plate fixation associated with posterior fixation via the K-L approach were divided into two groups: group A (screw fixation) and group B (plate fixation). Surgical time, blood loss, incision length for anterior fixation and complications were recorded. Fracture reduction quality was evaluated using criteria described by Matta. Fracture healing was assessed on the series of pelvic radiographs at each follow-up. Functional outcomes were investigated using the modified Postel Merle D’Aubigne score at the final follow-up. RESULTS: Twenty-nine patients with TOAFs, including 12 patients in group A and 17 patients in group B, were evaluated for study eligibility. The mean surgical time of anterior fracture fixation was 18.7 ± 4.6 min in group A and 33.4 ± 5.0 min in group B (P < 0.001). The amount of intraoperative blood loss was 615.6 ± 178.7 ml in group A and 719.3 ± 199.0 ml in group B (P < 0.001). Incision length for anterior fixation was 9.0 ± 1.8 mm in group A and 81.2 ± 7.3 mm in group B (P < 0.001). The complications related to the surgery of anterior column only occurred in group B (lateral femoral cutaneous nerve palsy in 1 patient and groin discomfort in 1 patient). No significant differences in reduction quality, hospital stay, fracture healing time and functional results were noted between the two groups. CONCLUSION: The K-L approach combined with robot-aided anterior column screw fixation is a safe and effective option for TOAFs. Compared with minimally invasive anterior plate fixation, robot-aided screw fixation has obvious advantages on surgical time, blood loss, and invasiveness. The K-L approach combined with minimally invasive anterior plate fixation can also be a reliable alternative for TOAFs, with the similar reduction quality and functional results. BioMed Central 2022-04-11 /pmc/articles/PMC8996653/ /pubmed/35410204 http://dx.doi.org/10.1186/s12891-022-05313-w Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Liu, Zhao-jie
Gu, Ya
Jia, Jian
The Kocher-Langenbeck approach combined with robot-aided percutaneous anterior column screw fixation for transverse-oriented acetabular fractures: a retrospective study
title The Kocher-Langenbeck approach combined with robot-aided percutaneous anterior column screw fixation for transverse-oriented acetabular fractures: a retrospective study
title_full The Kocher-Langenbeck approach combined with robot-aided percutaneous anterior column screw fixation for transverse-oriented acetabular fractures: a retrospective study
title_fullStr The Kocher-Langenbeck approach combined with robot-aided percutaneous anterior column screw fixation for transverse-oriented acetabular fractures: a retrospective study
title_full_unstemmed The Kocher-Langenbeck approach combined with robot-aided percutaneous anterior column screw fixation for transverse-oriented acetabular fractures: a retrospective study
title_short The Kocher-Langenbeck approach combined with robot-aided percutaneous anterior column screw fixation for transverse-oriented acetabular fractures: a retrospective study
title_sort kocher-langenbeck approach combined with robot-aided percutaneous anterior column screw fixation for transverse-oriented acetabular fractures: a retrospective study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8996653/
https://www.ncbi.nlm.nih.gov/pubmed/35410204
http://dx.doi.org/10.1186/s12891-022-05313-w
work_keys_str_mv AT liuzhaojie thekocherlangenbeckapproachcombinedwithrobotaidedpercutaneousanteriorcolumnscrewfixationfortransverseorientedacetabularfracturesaretrospectivestudy
AT guya thekocherlangenbeckapproachcombinedwithrobotaidedpercutaneousanteriorcolumnscrewfixationfortransverseorientedacetabularfracturesaretrospectivestudy
AT jiajian thekocherlangenbeckapproachcombinedwithrobotaidedpercutaneousanteriorcolumnscrewfixationfortransverseorientedacetabularfracturesaretrospectivestudy
AT liuzhaojie kocherlangenbeckapproachcombinedwithrobotaidedpercutaneousanteriorcolumnscrewfixationfortransverseorientedacetabularfracturesaretrospectivestudy
AT guya kocherlangenbeckapproachcombinedwithrobotaidedpercutaneousanteriorcolumnscrewfixationfortransverseorientedacetabularfracturesaretrospectivestudy
AT jiajian kocherlangenbeckapproachcombinedwithrobotaidedpercutaneousanteriorcolumnscrewfixationfortransverseorientedacetabularfracturesaretrospectivestudy