Cargando…

The Influence of Motion on the Delivery Accuracy When Comparing Actively Scanned Carbon Ions versus Protons at a Synchrotron-Based Radiotherapy Facility

SIMPLE SUMMARY: The interplay of breathing and beam motion reduces the efficacy of particle irradiation in moving tumours. The effect of motion on protons and carbon ion treatments was investigated dosimetrically and the results were benchmarked against each other by employing an anthropomorphic tho...

Descripción completa

Detalles Bibliográficos
Autores principales: Lebbink, Franciska, Stock, Markus, Georg, Dietmar, Knäusl, Barbara
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8997550/
https://www.ncbi.nlm.nih.gov/pubmed/35406558
http://dx.doi.org/10.3390/cancers14071788
_version_ 1784684732612608000
author Lebbink, Franciska
Stock, Markus
Georg, Dietmar
Knäusl, Barbara
author_facet Lebbink, Franciska
Stock, Markus
Georg, Dietmar
Knäusl, Barbara
author_sort Lebbink, Franciska
collection PubMed
description SIMPLE SUMMARY: The interplay of breathing and beam motion reduces the efficacy of particle irradiation in moving tumours. The effect of motion on protons and carbon ion treatments was investigated dosimetrically and the results were benchmarked against each other by employing an anthropomorphic thorax phantom that was able to simulate tumour, rib, and lung motion. The critical question was whether target coverage and organ-at-risk sparing could be maintained when the application of simple motion mitigation was addressed. Special focus was put on unique synchrotron characteristics, such as pulsed beam delivery and beam intensity variations. It could be demonstrated that the effect of motion was greater for carbon ions than for protons. These findings demonstrated the need for applying motion mitigation techniques depending on the motion amplitude, particle type, and treatment prescription considering complex time correlations. ABSTRACT: Motion amplitudes, in need of mitigation for moving targets irradiated with pulsed carbon ions and protons, were identified to guide the decision on treatment and motion mitigation strategy. Measurements with PinPoint ionisation chambers positioned in an anthropomorphic breathing phantom were acquired to investigate different tumour motion scenarios, including rib and lung movements. The effect of beam delivery dynamics and spot characteristics was considered. The dose in the tumour centre was deteriorated up to 10% for carbon ions but only up to 5% for protons. Dose deviations in the penumbra increased by a factor of two when comparing carbon ions to protons, ranging from 2 to 30% for an increasing motion amplitude that was strongly dependent on the beam intensity. Layer rescanning was able to diminish the dose distortion caused by tumour motion, but an increase in spot size could reduce it even further to 5% within the target and 10% at the penumbra. An increased need for motion mitigation of carbon ions compared to protons was identified to assure target coverage and sparing of adjacent organs at risk in the penumbra region and outside the target. For the clinical implementation of moving target treatments at a synchrotron-based particle facility complex, time dependencies needed to be considered.
format Online
Article
Text
id pubmed-8997550
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-89975502022-04-12 The Influence of Motion on the Delivery Accuracy When Comparing Actively Scanned Carbon Ions versus Protons at a Synchrotron-Based Radiotherapy Facility Lebbink, Franciska Stock, Markus Georg, Dietmar Knäusl, Barbara Cancers (Basel) Article SIMPLE SUMMARY: The interplay of breathing and beam motion reduces the efficacy of particle irradiation in moving tumours. The effect of motion on protons and carbon ion treatments was investigated dosimetrically and the results were benchmarked against each other by employing an anthropomorphic thorax phantom that was able to simulate tumour, rib, and lung motion. The critical question was whether target coverage and organ-at-risk sparing could be maintained when the application of simple motion mitigation was addressed. Special focus was put on unique synchrotron characteristics, such as pulsed beam delivery and beam intensity variations. It could be demonstrated that the effect of motion was greater for carbon ions than for protons. These findings demonstrated the need for applying motion mitigation techniques depending on the motion amplitude, particle type, and treatment prescription considering complex time correlations. ABSTRACT: Motion amplitudes, in need of mitigation for moving targets irradiated with pulsed carbon ions and protons, were identified to guide the decision on treatment and motion mitigation strategy. Measurements with PinPoint ionisation chambers positioned in an anthropomorphic breathing phantom were acquired to investigate different tumour motion scenarios, including rib and lung movements. The effect of beam delivery dynamics and spot characteristics was considered. The dose in the tumour centre was deteriorated up to 10% for carbon ions but only up to 5% for protons. Dose deviations in the penumbra increased by a factor of two when comparing carbon ions to protons, ranging from 2 to 30% for an increasing motion amplitude that was strongly dependent on the beam intensity. Layer rescanning was able to diminish the dose distortion caused by tumour motion, but an increase in spot size could reduce it even further to 5% within the target and 10% at the penumbra. An increased need for motion mitigation of carbon ions compared to protons was identified to assure target coverage and sparing of adjacent organs at risk in the penumbra region and outside the target. For the clinical implementation of moving target treatments at a synchrotron-based particle facility complex, time dependencies needed to be considered. MDPI 2022-03-31 /pmc/articles/PMC8997550/ /pubmed/35406558 http://dx.doi.org/10.3390/cancers14071788 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lebbink, Franciska
Stock, Markus
Georg, Dietmar
Knäusl, Barbara
The Influence of Motion on the Delivery Accuracy When Comparing Actively Scanned Carbon Ions versus Protons at a Synchrotron-Based Radiotherapy Facility
title The Influence of Motion on the Delivery Accuracy When Comparing Actively Scanned Carbon Ions versus Protons at a Synchrotron-Based Radiotherapy Facility
title_full The Influence of Motion on the Delivery Accuracy When Comparing Actively Scanned Carbon Ions versus Protons at a Synchrotron-Based Radiotherapy Facility
title_fullStr The Influence of Motion on the Delivery Accuracy When Comparing Actively Scanned Carbon Ions versus Protons at a Synchrotron-Based Radiotherapy Facility
title_full_unstemmed The Influence of Motion on the Delivery Accuracy When Comparing Actively Scanned Carbon Ions versus Protons at a Synchrotron-Based Radiotherapy Facility
title_short The Influence of Motion on the Delivery Accuracy When Comparing Actively Scanned Carbon Ions versus Protons at a Synchrotron-Based Radiotherapy Facility
title_sort influence of motion on the delivery accuracy when comparing actively scanned carbon ions versus protons at a synchrotron-based radiotherapy facility
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8997550/
https://www.ncbi.nlm.nih.gov/pubmed/35406558
http://dx.doi.org/10.3390/cancers14071788
work_keys_str_mv AT lebbinkfranciska theinfluenceofmotiononthedeliveryaccuracywhencomparingactivelyscannedcarbonionsversusprotonsatasynchrotronbasedradiotherapyfacility
AT stockmarkus theinfluenceofmotiononthedeliveryaccuracywhencomparingactivelyscannedcarbonionsversusprotonsatasynchrotronbasedradiotherapyfacility
AT georgdietmar theinfluenceofmotiononthedeliveryaccuracywhencomparingactivelyscannedcarbonionsversusprotonsatasynchrotronbasedradiotherapyfacility
AT knauslbarbara theinfluenceofmotiononthedeliveryaccuracywhencomparingactivelyscannedcarbonionsversusprotonsatasynchrotronbasedradiotherapyfacility
AT lebbinkfranciska influenceofmotiononthedeliveryaccuracywhencomparingactivelyscannedcarbonionsversusprotonsatasynchrotronbasedradiotherapyfacility
AT stockmarkus influenceofmotiononthedeliveryaccuracywhencomparingactivelyscannedcarbonionsversusprotonsatasynchrotronbasedradiotherapyfacility
AT georgdietmar influenceofmotiononthedeliveryaccuracywhencomparingactivelyscannedcarbonionsversusprotonsatasynchrotronbasedradiotherapyfacility
AT knauslbarbara influenceofmotiononthedeliveryaccuracywhencomparingactivelyscannedcarbonionsversusprotonsatasynchrotronbasedradiotherapyfacility