The stent-implantation process during angioplasty procedures usually involves clamping the stent onto a catheter to a size that allows delivery to the place inside the artery. Finding the right geometrical form of the stent to ensure good functionality in the open form and to enable the clamping pro...

Descripción completa

Detalles Bibliográficos
Autores principales: Molęda, Natalia, Kokot, Grzegorz, Kuś, Wacław, Sobota, Michał, Włodarczyk, Jakub, Stojko, Mateusz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8999420/
https://www.ncbi.nlm.nih.gov/pubmed/35407718
http://dx.doi.org/10.3390/ma15072385
_version_ 1784685181751263232
author Molęda, Natalia
Kokot, Grzegorz
Kuś, Wacław
Sobota, Michał
Włodarczyk, Jakub
Stojko, Mateusz
author_facet Molęda, Natalia
Kokot, Grzegorz
Kuś, Wacław
Sobota, Michał
Włodarczyk, Jakub
Stojko, Mateusz
author_sort Molęda, Natalia
collection PubMed
description The stent-implantation process during angioplasty procedures usually involves clamping the stent onto a catheter to a size that allows delivery to the place inside the artery. Finding the right geometrical form of the stent to ensure good functionality in the open form and to enable the clamping process is one of the key elements in the stent-design process. In the first part of the work, an original two-step procedure for stent-geometry design was proposed. This was due to the necessary selection of a geometry that would provide adequate support to the blood-vessel wall without causing damage to the vessel. Numerical simulations of the crimping and deployment processes were performed to verify the method. At the end of this stage, the optimal stent was selected for further testing. In addition, numerical simulations of selected experimental tests (catheter-crimping process, compression process) were used to verify the obtained geometrical forms. The results of experimental tests on stents produced by the microinjection method are presented. The digital image correlation (DIC) method was used to compare the results of numerical simulation and experimental tests. The two-step modeling approach was found to help select the appropriate geometry of the expanded stent, which is an extremely important step in the design of the crimping process. In the part of the paper where the results obtained by numerical simulation were compared with those gained by experiment and using the DIC method, a good compatibility of the displacement results can be observed. For both longitudinal and transverse (pinch) stent compression, the results practically coincide. The paper presents also the application of the DIC method which significantly expands the research possibilities, allowing for a detailed inspection of the deformation state and, above all, verification of local dangerous areas. This approach significantly increases the possibility of assessing the quality of the stents.
format Online
Article
Text
id pubmed-8999420
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-89994202022-04-12 Two-Step Geometry Design Method, Numerical Simulations and Experimental Studies of Bioresorbable Stents Molęda, Natalia Kokot, Grzegorz Kuś, Wacław Sobota, Michał Włodarczyk, Jakub Stojko, Mateusz Materials (Basel) Article The stent-implantation process during angioplasty procedures usually involves clamping the stent onto a catheter to a size that allows delivery to the place inside the artery. Finding the right geometrical form of the stent to ensure good functionality in the open form and to enable the clamping process is one of the key elements in the stent-design process. In the first part of the work, an original two-step procedure for stent-geometry design was proposed. This was due to the necessary selection of a geometry that would provide adequate support to the blood-vessel wall without causing damage to the vessel. Numerical simulations of the crimping and deployment processes were performed to verify the method. At the end of this stage, the optimal stent was selected for further testing. In addition, numerical simulations of selected experimental tests (catheter-crimping process, compression process) were used to verify the obtained geometrical forms. The results of experimental tests on stents produced by the microinjection method are presented. The digital image correlation (DIC) method was used to compare the results of numerical simulation and experimental tests. The two-step modeling approach was found to help select the appropriate geometry of the expanded stent, which is an extremely important step in the design of the crimping process. In the part of the paper where the results obtained by numerical simulation were compared with those gained by experiment and using the DIC method, a good compatibility of the displacement results can be observed. For both longitudinal and transverse (pinch) stent compression, the results practically coincide. The paper presents also the application of the DIC method which significantly expands the research possibilities, allowing for a detailed inspection of the deformation state and, above all, verification of local dangerous areas. This approach significantly increases the possibility of assessing the quality of the stents. MDPI 2022-03-24 /pmc/articles/PMC8999420/ /pubmed/35407718 http://dx.doi.org/10.3390/ma15072385 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Molęda, Natalia
Kokot, Grzegorz
Kuś, Wacław
Sobota, Michał
Włodarczyk, Jakub
Stojko, Mateusz
Two-Step Geometry Design Method, Numerical Simulations and Experimental Studies of Bioresorbable Stents
title Two-Step Geometry Design Method, Numerical Simulations and Experimental Studies of Bioresorbable Stents
title_full Two-Step Geometry Design Method, Numerical Simulations and Experimental Studies of Bioresorbable Stents
title_fullStr Two-Step Geometry Design Method, Numerical Simulations and Experimental Studies of Bioresorbable Stents
title_full_unstemmed Two-Step Geometry Design Method, Numerical Simulations and Experimental Studies of Bioresorbable Stents
title_short Two-Step Geometry Design Method, Numerical Simulations and Experimental Studies of Bioresorbable Stents
title_sort two-step geometry design method, numerical simulations and experimental studies of bioresorbable stents
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8999420/
https://www.ncbi.nlm.nih.gov/pubmed/35407718
http://dx.doi.org/10.3390/ma15072385
work_keys_str_mv AT moledanatalia twostepgeometrydesignmethodnumericalsimulationsandexperimentalstudiesofbioresorbablestents
AT kokotgrzegorz twostepgeometrydesignmethodnumericalsimulationsandexperimentalstudiesofbioresorbablestents
AT kuswacław twostepgeometrydesignmethodnumericalsimulationsandexperimentalstudiesofbioresorbablestents
AT sobotamichał twostepgeometrydesignmethodnumericalsimulationsandexperimentalstudiesofbioresorbablestents
AT włodarczykjakub twostepgeometrydesignmethodnumericalsimulationsandexperimentalstudiesofbioresorbablestents
AT stojkomateusz twostepgeometrydesignmethodnumericalsimulationsandexperimentalstudiesofbioresorbablestents