Embolic Protection with the TriGuard 3 System in Nonagenarian Patients Undergoing Transcatheter Aortic Valve Replacement for Severe Aortic Stenosis
Background: Transcatheter aortic valve replacement (TAVR) improves the survival and life quality of nonagenarian patients with aortic stenosis. Stroke remains one of the most worrisome complications following TAVR. Cerebral embolic protection devices (CEPDs) may reduce neurological complications aft...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8999484/ https://www.ncbi.nlm.nih.gov/pubmed/35407611 http://dx.doi.org/10.3390/jcm11072003 |
_version_ | 1784685196961906688 |
---|---|
author | Lind, Alexander Jánosi, Rolf Alexander Totzeck, Matthias Ruhparwar, Arjang Rassaf, Tienush Al-Rashid, Fadi |
author_facet | Lind, Alexander Jánosi, Rolf Alexander Totzeck, Matthias Ruhparwar, Arjang Rassaf, Tienush Al-Rashid, Fadi |
author_sort | Lind, Alexander |
collection | PubMed |
description | Background: Transcatheter aortic valve replacement (TAVR) improves the survival and life quality of nonagenarian patients with aortic stenosis. Stroke remains one of the most worrisome complications following TAVR. Cerebral embolic protection devices (CEPDs) may reduce neurological complications after TAVR. This study evaluated the safety and efficacy of CEPDs during TAVR in nonagenarian patients. Methods: Between January 2018 and October 2021, 869 patients underwent transfemoral TAVR (TF-TAVR) at our center. Of these, 51 (5.9%) patients were older than ninety years. In 33 consecutive nonagenarian patients, TF-TAVR was implanted without CEPDs using balloon-expandable valves (BEVs) and self-expandable valves (SEVs). Eighteen consecutive nonagenarians underwent TF-TAVR using a CEPD (CP group). Follow up period was in-hospital or 30 days after the procedure, respectively. Results: Minor access site complications occurred in two patients (3.9%) and were not CEPD-associated. Postinterventional delirium occurred in nine patients (17.6%). Periprocedural minor non-disabling stroke and delirium occurred in ten patients (19.6%). Periprocedural major fatal stroke occurred in two patients in the BEV group (3.9%). Two patients in the BEV group died due to postinterventional pneumonia with sepsis. The mortality rate was 7.8%. The results did not differ between the groups. Conclusions: Age alone is no longer a contraindication for TAVR. CEPD using the Triguard 3 system in nonagenarian TAVR patients was feasible and safe and did not increase access site complications. |
format | Online Article Text |
id | pubmed-8999484 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-89994842022-04-12 Embolic Protection with the TriGuard 3 System in Nonagenarian Patients Undergoing Transcatheter Aortic Valve Replacement for Severe Aortic Stenosis Lind, Alexander Jánosi, Rolf Alexander Totzeck, Matthias Ruhparwar, Arjang Rassaf, Tienush Al-Rashid, Fadi J Clin Med Article Background: Transcatheter aortic valve replacement (TAVR) improves the survival and life quality of nonagenarian patients with aortic stenosis. Stroke remains one of the most worrisome complications following TAVR. Cerebral embolic protection devices (CEPDs) may reduce neurological complications after TAVR. This study evaluated the safety and efficacy of CEPDs during TAVR in nonagenarian patients. Methods: Between January 2018 and October 2021, 869 patients underwent transfemoral TAVR (TF-TAVR) at our center. Of these, 51 (5.9%) patients were older than ninety years. In 33 consecutive nonagenarian patients, TF-TAVR was implanted without CEPDs using balloon-expandable valves (BEVs) and self-expandable valves (SEVs). Eighteen consecutive nonagenarians underwent TF-TAVR using a CEPD (CP group). Follow up period was in-hospital or 30 days after the procedure, respectively. Results: Minor access site complications occurred in two patients (3.9%) and were not CEPD-associated. Postinterventional delirium occurred in nine patients (17.6%). Periprocedural minor non-disabling stroke and delirium occurred in ten patients (19.6%). Periprocedural major fatal stroke occurred in two patients in the BEV group (3.9%). Two patients in the BEV group died due to postinterventional pneumonia with sepsis. The mortality rate was 7.8%. The results did not differ between the groups. Conclusions: Age alone is no longer a contraindication for TAVR. CEPD using the Triguard 3 system in nonagenarian TAVR patients was feasible and safe and did not increase access site complications. MDPI 2022-04-02 /pmc/articles/PMC8999484/ /pubmed/35407611 http://dx.doi.org/10.3390/jcm11072003 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Lind, Alexander Jánosi, Rolf Alexander Totzeck, Matthias Ruhparwar, Arjang Rassaf, Tienush Al-Rashid, Fadi Embolic Protection with the TriGuard 3 System in Nonagenarian Patients Undergoing Transcatheter Aortic Valve Replacement for Severe Aortic Stenosis |
title | Embolic Protection with the TriGuard 3 System in Nonagenarian Patients Undergoing Transcatheter Aortic Valve Replacement for Severe Aortic Stenosis |
title_full | Embolic Protection with the TriGuard 3 System in Nonagenarian Patients Undergoing Transcatheter Aortic Valve Replacement for Severe Aortic Stenosis |
title_fullStr | Embolic Protection with the TriGuard 3 System in Nonagenarian Patients Undergoing Transcatheter Aortic Valve Replacement for Severe Aortic Stenosis |
title_full_unstemmed | Embolic Protection with the TriGuard 3 System in Nonagenarian Patients Undergoing Transcatheter Aortic Valve Replacement for Severe Aortic Stenosis |
title_short | Embolic Protection with the TriGuard 3 System in Nonagenarian Patients Undergoing Transcatheter Aortic Valve Replacement for Severe Aortic Stenosis |
title_sort | embolic protection with the triguard 3 system in nonagenarian patients undergoing transcatheter aortic valve replacement for severe aortic stenosis |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8999484/ https://www.ncbi.nlm.nih.gov/pubmed/35407611 http://dx.doi.org/10.3390/jcm11072003 |
work_keys_str_mv | AT lindalexander embolicprotectionwiththetriguard3systeminnonagenarianpatientsundergoingtranscatheteraorticvalvereplacementforsevereaorticstenosis AT janosirolfalexander embolicprotectionwiththetriguard3systeminnonagenarianpatientsundergoingtranscatheteraorticvalvereplacementforsevereaorticstenosis AT totzeckmatthias embolicprotectionwiththetriguard3systeminnonagenarianpatientsundergoingtranscatheteraorticvalvereplacementforsevereaorticstenosis AT ruhparwararjang embolicprotectionwiththetriguard3systeminnonagenarianpatientsundergoingtranscatheteraorticvalvereplacementforsevereaorticstenosis AT rassaftienush embolicprotectionwiththetriguard3systeminnonagenarianpatientsundergoingtranscatheteraorticvalvereplacementforsevereaorticstenosis AT alrashidfadi embolicprotectionwiththetriguard3systeminnonagenarianpatientsundergoingtranscatheteraorticvalvereplacementforsevereaorticstenosis |