Cargando…

Temperature Changes during Implant Osteotomy Preparations in Fresh Human Cadaver Tibiae, Comparing Straight with Tapered Drills †

The success of osseointegration depends on many factors. With temperatures beyond a 47 °C threshold over 1 min, bone survival may be impaired. The purpose of the study was to evaluate, in fresh human cadaver tibiae, the temperature changes during osteotomy preparations using two straight and two tap...

Descripción completa

Detalles Bibliográficos
Autores principales: Soldatos, Nikolaos, Nelson-Rabe, Laura, Palanker, Nathan, Angelov, Nikola, Romanos, Georgios, Weltman, Robin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8999768/
https://www.ncbi.nlm.nih.gov/pubmed/35407704
http://dx.doi.org/10.3390/ma15072369
_version_ 1784685269201453056
author Soldatos, Nikolaos
Nelson-Rabe, Laura
Palanker, Nathan
Angelov, Nikola
Romanos, Georgios
Weltman, Robin
author_facet Soldatos, Nikolaos
Nelson-Rabe, Laura
Palanker, Nathan
Angelov, Nikola
Romanos, Georgios
Weltman, Robin
author_sort Soldatos, Nikolaos
collection PubMed
description The success of osseointegration depends on many factors. With temperatures beyond a 47 °C threshold over 1 min, bone survival may be impaired. The purpose of the study was to evaluate, in fresh human cadaver tibiae, the temperature changes during osteotomy preparations using two straight and two tapered implant systems’ drills, external irrigation, and varying revolutions per minute (RPM). The tibiae from a fresh female cadaver were harvested bilaterally. Two tapered and two straight design drills were assessed. Two-hundred and forty osteotomies were prepared at 6 mm depth following the drill sequence of the manufacturers’ protocol for each drilling speed. Difference in temperature (ΔΤ) was calculated by subtracting the baseline from the maximum temperature (ΔT = T(max) − T(base)). Drill design and drill diameter, as independent variables or synergistically, had a significant effect on ΔΤ. Tapered drills: As the drill diameter increased, ΔΤ increased at all RPM. Straight drills: As the drill diameter increased, ΔΤ remained constant or slightly decreased at all RPM. Drill diameter and design had a significant effect on ΔΤ in human tibiae, which never exceeded the critical threshold of 47 °C. Tapered drills caused significantly greater heat production compared to straight drills.
format Online
Article
Text
id pubmed-8999768
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-89997682022-04-12 Temperature Changes during Implant Osteotomy Preparations in Fresh Human Cadaver Tibiae, Comparing Straight with Tapered Drills † Soldatos, Nikolaos Nelson-Rabe, Laura Palanker, Nathan Angelov, Nikola Romanos, Georgios Weltman, Robin Materials (Basel) Article The success of osseointegration depends on many factors. With temperatures beyond a 47 °C threshold over 1 min, bone survival may be impaired. The purpose of the study was to evaluate, in fresh human cadaver tibiae, the temperature changes during osteotomy preparations using two straight and two tapered implant systems’ drills, external irrigation, and varying revolutions per minute (RPM). The tibiae from a fresh female cadaver were harvested bilaterally. Two tapered and two straight design drills were assessed. Two-hundred and forty osteotomies were prepared at 6 mm depth following the drill sequence of the manufacturers’ protocol for each drilling speed. Difference in temperature (ΔΤ) was calculated by subtracting the baseline from the maximum temperature (ΔT = T(max) − T(base)). Drill design and drill diameter, as independent variables or synergistically, had a significant effect on ΔΤ. Tapered drills: As the drill diameter increased, ΔΤ increased at all RPM. Straight drills: As the drill diameter increased, ΔΤ remained constant or slightly decreased at all RPM. Drill diameter and design had a significant effect on ΔΤ in human tibiae, which never exceeded the critical threshold of 47 °C. Tapered drills caused significantly greater heat production compared to straight drills. MDPI 2022-03-23 /pmc/articles/PMC8999768/ /pubmed/35407704 http://dx.doi.org/10.3390/ma15072369 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Soldatos, Nikolaos
Nelson-Rabe, Laura
Palanker, Nathan
Angelov, Nikola
Romanos, Georgios
Weltman, Robin
Temperature Changes during Implant Osteotomy Preparations in Fresh Human Cadaver Tibiae, Comparing Straight with Tapered Drills †
title Temperature Changes during Implant Osteotomy Preparations in Fresh Human Cadaver Tibiae, Comparing Straight with Tapered Drills †
title_full Temperature Changes during Implant Osteotomy Preparations in Fresh Human Cadaver Tibiae, Comparing Straight with Tapered Drills †
title_fullStr Temperature Changes during Implant Osteotomy Preparations in Fresh Human Cadaver Tibiae, Comparing Straight with Tapered Drills †
title_full_unstemmed Temperature Changes during Implant Osteotomy Preparations in Fresh Human Cadaver Tibiae, Comparing Straight with Tapered Drills †
title_short Temperature Changes during Implant Osteotomy Preparations in Fresh Human Cadaver Tibiae, Comparing Straight with Tapered Drills †
title_sort temperature changes during implant osteotomy preparations in fresh human cadaver tibiae, comparing straight with tapered drills †
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8999768/
https://www.ncbi.nlm.nih.gov/pubmed/35407704
http://dx.doi.org/10.3390/ma15072369
work_keys_str_mv AT soldatosnikolaos temperaturechangesduringimplantosteotomypreparationsinfreshhumancadavertibiaecomparingstraightwithtapereddrills
AT nelsonrabelaura temperaturechangesduringimplantosteotomypreparationsinfreshhumancadavertibiaecomparingstraightwithtapereddrills
AT palankernathan temperaturechangesduringimplantosteotomypreparationsinfreshhumancadavertibiaecomparingstraightwithtapereddrills
AT angelovnikola temperaturechangesduringimplantosteotomypreparationsinfreshhumancadavertibiaecomparingstraightwithtapereddrills
AT romanosgeorgios temperaturechangesduringimplantosteotomypreparationsinfreshhumancadavertibiaecomparingstraightwithtapereddrills
AT weltmanrobin temperaturechangesduringimplantosteotomypreparationsinfreshhumancadavertibiaecomparingstraightwithtapereddrills