Evaluation of the Fitting Accuracy of CAD/CAM-Manufactured Patient-Specific Implants for the Reconstruction of Cranial Defects—A Retrospective Study

Cranioplasties show overall high complication rates of up to 45.3%. Risk factors potentially associated with the occurrence of postoperative complications are frequently discussed in existing research. The present study examines the positioning of 39 patient-specific implants (PSI) made from polyeth...

Descripción completa

Detalles Bibliográficos
Autores principales: Moellmann, Henriette L., Mehr, Vanessa N., Karnatz, Nadia, Wilkat, Max, Riedel, Erik, Rana, Majeed
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9000016/
https://www.ncbi.nlm.nih.gov/pubmed/35407653
http://dx.doi.org/10.3390/jcm11072045
_version_ 1784685329950703616
author Moellmann, Henriette L.
Mehr, Vanessa N.
Karnatz, Nadia
Wilkat, Max
Riedel, Erik
Rana, Majeed
author_facet Moellmann, Henriette L.
Mehr, Vanessa N.
Karnatz, Nadia
Wilkat, Max
Riedel, Erik
Rana, Majeed
author_sort Moellmann, Henriette L.
collection PubMed
description Cranioplasties show overall high complication rates of up to 45.3%. Risk factors potentially associated with the occurrence of postoperative complications are frequently discussed in existing research. The present study examines the positioning of 39 patient-specific implants (PSI) made from polyetheretherketone (PEEK) and retrospectively investigates the relationship between the fitting accuracy and incidence of postoperative complications. To analyze the fitting accuracy of the implants pre- and post-operatively, STL files were created and superimposed in a 3D coordinate system, and the deviations were graphically displayed and evaluated along with the postoperative complications. On average, 95.17% (SD = 9.42) of the measurements between planned and surgically achieved implant position were within the defined tolerance range. In cases with lower accordance, an increased occurrence of complications could not be demonstrated. The overall postoperative complication rate was 64.1%. The fitting of the PEEK-PSI was highly satisfactory. There were predominantly minor deviations of the achieved compared to the planned implant positions; however, estimations were within the defined tolerance range. Despite the overall high accuracy of fitting, a considerable complication rate was found. To optimize the surgical outcome, the focus should instead be directed towards the investigation of other risk factors.
format Online
Article
Text
id pubmed-9000016
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-90000162022-04-12 Evaluation of the Fitting Accuracy of CAD/CAM-Manufactured Patient-Specific Implants for the Reconstruction of Cranial Defects—A Retrospective Study Moellmann, Henriette L. Mehr, Vanessa N. Karnatz, Nadia Wilkat, Max Riedel, Erik Rana, Majeed J Clin Med Article Cranioplasties show overall high complication rates of up to 45.3%. Risk factors potentially associated with the occurrence of postoperative complications are frequently discussed in existing research. The present study examines the positioning of 39 patient-specific implants (PSI) made from polyetheretherketone (PEEK) and retrospectively investigates the relationship between the fitting accuracy and incidence of postoperative complications. To analyze the fitting accuracy of the implants pre- and post-operatively, STL files were created and superimposed in a 3D coordinate system, and the deviations were graphically displayed and evaluated along with the postoperative complications. On average, 95.17% (SD = 9.42) of the measurements between planned and surgically achieved implant position were within the defined tolerance range. In cases with lower accordance, an increased occurrence of complications could not be demonstrated. The overall postoperative complication rate was 64.1%. The fitting of the PEEK-PSI was highly satisfactory. There were predominantly minor deviations of the achieved compared to the planned implant positions; however, estimations were within the defined tolerance range. Despite the overall high accuracy of fitting, a considerable complication rate was found. To optimize the surgical outcome, the focus should instead be directed towards the investigation of other risk factors. MDPI 2022-04-06 /pmc/articles/PMC9000016/ /pubmed/35407653 http://dx.doi.org/10.3390/jcm11072045 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Moellmann, Henriette L.
Mehr, Vanessa N.
Karnatz, Nadia
Wilkat, Max
Riedel, Erik
Rana, Majeed
Evaluation of the Fitting Accuracy of CAD/CAM-Manufactured Patient-Specific Implants for the Reconstruction of Cranial Defects—A Retrospective Study
title Evaluation of the Fitting Accuracy of CAD/CAM-Manufactured Patient-Specific Implants for the Reconstruction of Cranial Defects—A Retrospective Study
title_full Evaluation of the Fitting Accuracy of CAD/CAM-Manufactured Patient-Specific Implants for the Reconstruction of Cranial Defects—A Retrospective Study
title_fullStr Evaluation of the Fitting Accuracy of CAD/CAM-Manufactured Patient-Specific Implants for the Reconstruction of Cranial Defects—A Retrospective Study
title_full_unstemmed Evaluation of the Fitting Accuracy of CAD/CAM-Manufactured Patient-Specific Implants for the Reconstruction of Cranial Defects—A Retrospective Study
title_short Evaluation of the Fitting Accuracy of CAD/CAM-Manufactured Patient-Specific Implants for the Reconstruction of Cranial Defects—A Retrospective Study
title_sort evaluation of the fitting accuracy of cad/cam-manufactured patient-specific implants for the reconstruction of cranial defects—a retrospective study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9000016/
https://www.ncbi.nlm.nih.gov/pubmed/35407653
http://dx.doi.org/10.3390/jcm11072045
work_keys_str_mv AT moellmannhenriettel evaluationofthefittingaccuracyofcadcammanufacturedpatientspecificimplantsforthereconstructionofcranialdefectsaretrospectivestudy
AT mehrvanessan evaluationofthefittingaccuracyofcadcammanufacturedpatientspecificimplantsforthereconstructionofcranialdefectsaretrospectivestudy
AT karnatznadia evaluationofthefittingaccuracyofcadcammanufacturedpatientspecificimplantsforthereconstructionofcranialdefectsaretrospectivestudy
AT wilkatmax evaluationofthefittingaccuracyofcadcammanufacturedpatientspecificimplantsforthereconstructionofcranialdefectsaretrospectivestudy
AT riedelerik evaluationofthefittingaccuracyofcadcammanufacturedpatientspecificimplantsforthereconstructionofcranialdefectsaretrospectivestudy
AT ranamajeed evaluationofthefittingaccuracyofcadcammanufacturedpatientspecificimplantsforthereconstructionofcranialdefectsaretrospectivestudy