Cargando…

Subjective Sound Quality Detection (HISQUI) over Time after Vibrant Soundbridge Implantation

Background: To evaluate the long-term audiological outcomes combined with the Hearing Implant Sound Quality Index (HISQUI) after Vibrant Soundbridge (VSB) implantation. Methods: Prospective recall cohort study of patients who received a VSB in a tertiary academic medical center between 1996 and 2017...

Descripción completa

Detalles Bibliográficos
Autores principales: Buhl, Christof, Schindler, Valeria, Pfiffner, Flurin, Veraguth, Dorothe, Huber, Alexander, Röösli, Christof
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9000017/
https://www.ncbi.nlm.nih.gov/pubmed/35407420
http://dx.doi.org/10.3390/jcm11071811
_version_ 1784685330226479104
author Buhl, Christof
Schindler, Valeria
Pfiffner, Flurin
Veraguth, Dorothe
Huber, Alexander
Röösli, Christof
author_facet Buhl, Christof
Schindler, Valeria
Pfiffner, Flurin
Veraguth, Dorothe
Huber, Alexander
Röösli, Christof
author_sort Buhl, Christof
collection PubMed
description Background: To evaluate the long-term audiological outcomes combined with the Hearing Implant Sound Quality Index (HISQUI) after Vibrant Soundbridge (VSB) implantation. Methods: Prospective recall cohort study of patients who received a VSB in a tertiary academic medical center between 1996 and 2017. Air conduction (AC) and bone conduction (BC), sound field thresholds in aided and unaided conditions, and speech discrimination in noise (Oldenburger sentence test) were measured. Postoperative results were compared with preoperative audiograms. Furthermore, the HISQUI was evaluated. Results: Ten patients (eleven implants) were included, the mean follow up period was nine years. The mean AC threshold preoperatively was between 63 and 70 dB, and the BC was between 38 and 49 dB from 500 to 4000 Hz. In the free-field audiogram, the mean threshold was between 61 and 77 dB unaided vs. between 28 and 52 dB in the aided condition. The average signal to noise ratio (SNR) in the Oldenburger sentence test in the unaided condition was 10 dB ± 6.7 dB vs. 2 dB ± 5.4 dB in the aided condition. Three patients reported a good to very good hearing result, four patients a moderate, and three patients a poor hearing result. There was a significant association between the years of implantation and the HISQUI (p = 0.013), as well as a significant decrease by 14 HISQUI points per 10 dB SPL decline (SE 5.2, p = 0.023). There was a significant difference between the change of BC over the years and the HISQUI, as well as the number of years after implantation and the HISQUI. On average, per dB decrease in BC, the HISQUI decreases by 1.4 points, and every year after implantation the HISQUI decreases by 2.7 points. Conclusions: The aided threshold in free field and speech understanding in noise improved significantly with VSB. An increase over time of BC thresholds was observed as well as a decrease in HISQUI score. This decrease in BC thresholds over time may be due to presbycusis. Therefore, monitoring of these patients over time should be considered to discuss alternative hearing rehabilitation measures in a timely manner.
format Online
Article
Text
id pubmed-9000017
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-90000172022-04-12 Subjective Sound Quality Detection (HISQUI) over Time after Vibrant Soundbridge Implantation Buhl, Christof Schindler, Valeria Pfiffner, Flurin Veraguth, Dorothe Huber, Alexander Röösli, Christof J Clin Med Article Background: To evaluate the long-term audiological outcomes combined with the Hearing Implant Sound Quality Index (HISQUI) after Vibrant Soundbridge (VSB) implantation. Methods: Prospective recall cohort study of patients who received a VSB in a tertiary academic medical center between 1996 and 2017. Air conduction (AC) and bone conduction (BC), sound field thresholds in aided and unaided conditions, and speech discrimination in noise (Oldenburger sentence test) were measured. Postoperative results were compared with preoperative audiograms. Furthermore, the HISQUI was evaluated. Results: Ten patients (eleven implants) were included, the mean follow up period was nine years. The mean AC threshold preoperatively was between 63 and 70 dB, and the BC was between 38 and 49 dB from 500 to 4000 Hz. In the free-field audiogram, the mean threshold was between 61 and 77 dB unaided vs. between 28 and 52 dB in the aided condition. The average signal to noise ratio (SNR) in the Oldenburger sentence test in the unaided condition was 10 dB ± 6.7 dB vs. 2 dB ± 5.4 dB in the aided condition. Three patients reported a good to very good hearing result, four patients a moderate, and three patients a poor hearing result. There was a significant association between the years of implantation and the HISQUI (p = 0.013), as well as a significant decrease by 14 HISQUI points per 10 dB SPL decline (SE 5.2, p = 0.023). There was a significant difference between the change of BC over the years and the HISQUI, as well as the number of years after implantation and the HISQUI. On average, per dB decrease in BC, the HISQUI decreases by 1.4 points, and every year after implantation the HISQUI decreases by 2.7 points. Conclusions: The aided threshold in free field and speech understanding in noise improved significantly with VSB. An increase over time of BC thresholds was observed as well as a decrease in HISQUI score. This decrease in BC thresholds over time may be due to presbycusis. Therefore, monitoring of these patients over time should be considered to discuss alternative hearing rehabilitation measures in a timely manner. MDPI 2022-03-25 /pmc/articles/PMC9000017/ /pubmed/35407420 http://dx.doi.org/10.3390/jcm11071811 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Buhl, Christof
Schindler, Valeria
Pfiffner, Flurin
Veraguth, Dorothe
Huber, Alexander
Röösli, Christof
Subjective Sound Quality Detection (HISQUI) over Time after Vibrant Soundbridge Implantation
title Subjective Sound Quality Detection (HISQUI) over Time after Vibrant Soundbridge Implantation
title_full Subjective Sound Quality Detection (HISQUI) over Time after Vibrant Soundbridge Implantation
title_fullStr Subjective Sound Quality Detection (HISQUI) over Time after Vibrant Soundbridge Implantation
title_full_unstemmed Subjective Sound Quality Detection (HISQUI) over Time after Vibrant Soundbridge Implantation
title_short Subjective Sound Quality Detection (HISQUI) over Time after Vibrant Soundbridge Implantation
title_sort subjective sound quality detection (hisqui) over time after vibrant soundbridge implantation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9000017/
https://www.ncbi.nlm.nih.gov/pubmed/35407420
http://dx.doi.org/10.3390/jcm11071811
work_keys_str_mv AT buhlchristof subjectivesoundqualitydetectionhisquiovertimeaftervibrantsoundbridgeimplantation
AT schindlervaleria subjectivesoundqualitydetectionhisquiovertimeaftervibrantsoundbridgeimplantation
AT pfiffnerflurin subjectivesoundqualitydetectionhisquiovertimeaftervibrantsoundbridgeimplantation
AT veraguthdorothe subjectivesoundqualitydetectionhisquiovertimeaftervibrantsoundbridgeimplantation
AT huberalexander subjectivesoundqualitydetectionhisquiovertimeaftervibrantsoundbridgeimplantation
AT rooslichristof subjectivesoundqualitydetectionhisquiovertimeaftervibrantsoundbridgeimplantation