Cargando…

Characteristics of Conventional and Microwave Sintered Iron Ore Preform

In this study, compacted hematite (Fe(2)O(3)) preforms were made and sintered at various temperatures, such as 1250 °C and 1300 °C, using both conventional and microwave sintering methods. The density, porosity, microhardness, cold crushing strength, microphotographs, and X-ray diffraction (XRD) ana...

Descripción completa

Detalles Bibliográficos
Autores principales: Equbal, Azhar, Ali, Mohammad, Equbal, Md. Asif, Srivastava, S. C., Khan, Zahid A., Equbal, Md. Israr, Badruddin, Irfan Anjum, El-Hady, Khalid Mohamed, Kamangar, Sarfaraz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9000582/
https://www.ncbi.nlm.nih.gov/pubmed/35407987
http://dx.doi.org/10.3390/ma15072655
_version_ 1784685469619978240
author Equbal, Azhar
Ali, Mohammad
Equbal, Md. Asif
Srivastava, S. C.
Khan, Zahid A.
Equbal, Md. Israr
Badruddin, Irfan Anjum
El-Hady, Khalid Mohamed
Kamangar, Sarfaraz
author_facet Equbal, Azhar
Ali, Mohammad
Equbal, Md. Asif
Srivastava, S. C.
Khan, Zahid A.
Equbal, Md. Israr
Badruddin, Irfan Anjum
El-Hady, Khalid Mohamed
Kamangar, Sarfaraz
author_sort Equbal, Azhar
collection PubMed
description In this study, compacted hematite (Fe(2)O(3)) preforms were made and sintered at various temperatures, such as 1250 °C and 1300 °C, using both conventional and microwave sintering methods. The density, porosity, microhardness, cold crushing strength, microphotographs, and X-ray diffraction (XRD) analysis of the sintered preforms were used to evaluate the performance of the two sintering methods. It was found that microwave sintered preforms possessed lesser porosity and higher density than conventionally sintered preforms owing to uniform heating of the powdered ore in microwave sintering method. Furthermore, it was also observed that microwave sintered preforms exhibited relatively higher cold crushing strength and hardness than conventionally sintered preforms. Thus, the overall results revealed that microwave sintering yielded better properties considered in the present study.
format Online
Article
Text
id pubmed-9000582
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-90005822022-04-12 Characteristics of Conventional and Microwave Sintered Iron Ore Preform Equbal, Azhar Ali, Mohammad Equbal, Md. Asif Srivastava, S. C. Khan, Zahid A. Equbal, Md. Israr Badruddin, Irfan Anjum El-Hady, Khalid Mohamed Kamangar, Sarfaraz Materials (Basel) Article In this study, compacted hematite (Fe(2)O(3)) preforms were made and sintered at various temperatures, such as 1250 °C and 1300 °C, using both conventional and microwave sintering methods. The density, porosity, microhardness, cold crushing strength, microphotographs, and X-ray diffraction (XRD) analysis of the sintered preforms were used to evaluate the performance of the two sintering methods. It was found that microwave sintered preforms possessed lesser porosity and higher density than conventionally sintered preforms owing to uniform heating of the powdered ore in microwave sintering method. Furthermore, it was also observed that microwave sintered preforms exhibited relatively higher cold crushing strength and hardness than conventionally sintered preforms. Thus, the overall results revealed that microwave sintering yielded better properties considered in the present study. MDPI 2022-04-04 /pmc/articles/PMC9000582/ /pubmed/35407987 http://dx.doi.org/10.3390/ma15072655 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Equbal, Azhar
Ali, Mohammad
Equbal, Md. Asif
Srivastava, S. C.
Khan, Zahid A.
Equbal, Md. Israr
Badruddin, Irfan Anjum
El-Hady, Khalid Mohamed
Kamangar, Sarfaraz
Characteristics of Conventional and Microwave Sintered Iron Ore Preform
title Characteristics of Conventional and Microwave Sintered Iron Ore Preform
title_full Characteristics of Conventional and Microwave Sintered Iron Ore Preform
title_fullStr Characteristics of Conventional and Microwave Sintered Iron Ore Preform
title_full_unstemmed Characteristics of Conventional and Microwave Sintered Iron Ore Preform
title_short Characteristics of Conventional and Microwave Sintered Iron Ore Preform
title_sort characteristics of conventional and microwave sintered iron ore preform
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9000582/
https://www.ncbi.nlm.nih.gov/pubmed/35407987
http://dx.doi.org/10.3390/ma15072655
work_keys_str_mv AT equbalazhar characteristicsofconventionalandmicrowavesinteredironorepreform
AT alimohammad characteristicsofconventionalandmicrowavesinteredironorepreform
AT equbalmdasif characteristicsofconventionalandmicrowavesinteredironorepreform
AT srivastavasc characteristicsofconventionalandmicrowavesinteredironorepreform
AT khanzahida characteristicsofconventionalandmicrowavesinteredironorepreform
AT equbalmdisrar characteristicsofconventionalandmicrowavesinteredironorepreform
AT badruddinirfananjum characteristicsofconventionalandmicrowavesinteredironorepreform
AT elhadykhalidmohamed characteristicsofconventionalandmicrowavesinteredironorepreform
AT kamangarsarfaraz characteristicsofconventionalandmicrowavesinteredironorepreform