Cargando…

Minimally Invasive Percutaneous Plate Osteosynthesis technique combined with locking compression plates guided by C-Arm X-Ray machine in treatment of tibial metaphyseal fractures: Curative effect and postoperative complications

OBJECTIVES: To explore the curative effect of minimally invasive percutaneous plate osteosynthesis (MIPPO) technology combined with locking compression plates (LCP) guided by C-arm X-ray machine in the treatment of tibial metaphyseal fracture and its impact on the surgical indexes and postoperative...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Xu, Liu, Bin, Wang, Quan, Shang, Hongtao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Professional Medical Publications 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9002447/
https://www.ncbi.nlm.nih.gov/pubmed/35480511
http://dx.doi.org/10.12669/pjms.38.3.4757
_version_ 1784685891882582016
author Zhang, Xu
Liu, Bin
Wang, Quan
Shang, Hongtao
author_facet Zhang, Xu
Liu, Bin
Wang, Quan
Shang, Hongtao
author_sort Zhang, Xu
collection PubMed
description OBJECTIVES: To explore the curative effect of minimally invasive percutaneous plate osteosynthesis (MIPPO) technology combined with locking compression plates (LCP) guided by C-arm X-ray machine in the treatment of tibial metaphyseal fracture and its impact on the surgical indexes and postoperative complications. METHODS: The present study was a retrospective analysis focusing on the clinical data of 104 cases of tibial metaphyseal fracture who were treated surgically in our hospital from February 2019 to February 2021. According to different surgical methods, patients who were treated by using MIPPO technology combined with LCP guided by C-arm X-ray machine were divided into the observation group (n=54), while those who underwent traditional open reduction and internal fixation were classified into the control group (n=50). Further comparison was made on the differences of the curative effect, surgical index (operation time, intraoperative blood loss, incision length, and healing time) and postoperative complications between the two groups. In addition, the differences in ankle function, knee function and quality of life [Medical Outcomes Study 36-item Short-Form Health Survey (MOS SF-36)] were evaluated between the two groups before treatment and 6 months after treatment. RESULTS: The clinical curative effect and total efficacy of the observation group were better than those of the control group (All p<0.05). The operation time, intraoperative blood loss, incision length, and healing time were lower in the observation group when compared to those of the control group (All p<0.05). The total incidence of postoperative complications was also lower in the observation group than that in the control group (p<0.05). In addition, the scores of ankle function, knee function and MOS SF-36 in both groups were higher after 6 months of treatment than those before treatment; besides, the inter-group comparison showed that the scores of ankle function, knee function and MOS SF-36 in the observation group were higher than those in the control group (All p<0.05). CONCLUSION: MIPPO technology combined with LCP guided by C-arm X-ray machine has a significant curative effect on the treatment of tibial metaphyseal fracture. It can significantly improve the surgical index, reduce postoperative complications, and have an obvious effect on postoperative recovery of ankle function, knee joint function and quality of life.
format Online
Article
Text
id pubmed-9002447
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Professional Medical Publications
record_format MEDLINE/PubMed
spelling pubmed-90024472022-04-26 Minimally Invasive Percutaneous Plate Osteosynthesis technique combined with locking compression plates guided by C-Arm X-Ray machine in treatment of tibial metaphyseal fractures: Curative effect and postoperative complications Zhang, Xu Liu, Bin Wang, Quan Shang, Hongtao Pak J Med Sci Orignal Article OBJECTIVES: To explore the curative effect of minimally invasive percutaneous plate osteosynthesis (MIPPO) technology combined with locking compression plates (LCP) guided by C-arm X-ray machine in the treatment of tibial metaphyseal fracture and its impact on the surgical indexes and postoperative complications. METHODS: The present study was a retrospective analysis focusing on the clinical data of 104 cases of tibial metaphyseal fracture who were treated surgically in our hospital from February 2019 to February 2021. According to different surgical methods, patients who were treated by using MIPPO technology combined with LCP guided by C-arm X-ray machine were divided into the observation group (n=54), while those who underwent traditional open reduction and internal fixation were classified into the control group (n=50). Further comparison was made on the differences of the curative effect, surgical index (operation time, intraoperative blood loss, incision length, and healing time) and postoperative complications between the two groups. In addition, the differences in ankle function, knee function and quality of life [Medical Outcomes Study 36-item Short-Form Health Survey (MOS SF-36)] were evaluated between the two groups before treatment and 6 months after treatment. RESULTS: The clinical curative effect and total efficacy of the observation group were better than those of the control group (All p<0.05). The operation time, intraoperative blood loss, incision length, and healing time were lower in the observation group when compared to those of the control group (All p<0.05). The total incidence of postoperative complications was also lower in the observation group than that in the control group (p<0.05). In addition, the scores of ankle function, knee function and MOS SF-36 in both groups were higher after 6 months of treatment than those before treatment; besides, the inter-group comparison showed that the scores of ankle function, knee function and MOS SF-36 in the observation group were higher than those in the control group (All p<0.05). CONCLUSION: MIPPO technology combined with LCP guided by C-arm X-ray machine has a significant curative effect on the treatment of tibial metaphyseal fracture. It can significantly improve the surgical index, reduce postoperative complications, and have an obvious effect on postoperative recovery of ankle function, knee joint function and quality of life. Professional Medical Publications 2022 /pmc/articles/PMC9002447/ /pubmed/35480511 http://dx.doi.org/10.12669/pjms.38.3.4757 Text en Copyright: © Pakistan Journal of Medical Sciences https://creativecommons.org/licenses/by/3.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0 (https://creativecommons.org/licenses/by/3.0/) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Orignal Article
Zhang, Xu
Liu, Bin
Wang, Quan
Shang, Hongtao
Minimally Invasive Percutaneous Plate Osteosynthesis technique combined with locking compression plates guided by C-Arm X-Ray machine in treatment of tibial metaphyseal fractures: Curative effect and postoperative complications
title Minimally Invasive Percutaneous Plate Osteosynthesis technique combined with locking compression plates guided by C-Arm X-Ray machine in treatment of tibial metaphyseal fractures: Curative effect and postoperative complications
title_full Minimally Invasive Percutaneous Plate Osteosynthesis technique combined with locking compression plates guided by C-Arm X-Ray machine in treatment of tibial metaphyseal fractures: Curative effect and postoperative complications
title_fullStr Minimally Invasive Percutaneous Plate Osteosynthesis technique combined with locking compression plates guided by C-Arm X-Ray machine in treatment of tibial metaphyseal fractures: Curative effect and postoperative complications
title_full_unstemmed Minimally Invasive Percutaneous Plate Osteosynthesis technique combined with locking compression plates guided by C-Arm X-Ray machine in treatment of tibial metaphyseal fractures: Curative effect and postoperative complications
title_short Minimally Invasive Percutaneous Plate Osteosynthesis technique combined with locking compression plates guided by C-Arm X-Ray machine in treatment of tibial metaphyseal fractures: Curative effect and postoperative complications
title_sort minimally invasive percutaneous plate osteosynthesis technique combined with locking compression plates guided by c-arm x-ray machine in treatment of tibial metaphyseal fractures: curative effect and postoperative complications
topic Orignal Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9002447/
https://www.ncbi.nlm.nih.gov/pubmed/35480511
http://dx.doi.org/10.12669/pjms.38.3.4757
work_keys_str_mv AT zhangxu minimallyinvasivepercutaneousplateosteosynthesistechniquecombinedwithlockingcompressionplatesguidedbycarmxraymachineintreatmentoftibialmetaphysealfracturescurativeeffectandpostoperativecomplications
AT liubin minimallyinvasivepercutaneousplateosteosynthesistechniquecombinedwithlockingcompressionplatesguidedbycarmxraymachineintreatmentoftibialmetaphysealfracturescurativeeffectandpostoperativecomplications
AT wangquan minimallyinvasivepercutaneousplateosteosynthesistechniquecombinedwithlockingcompressionplatesguidedbycarmxraymachineintreatmentoftibialmetaphysealfracturescurativeeffectandpostoperativecomplications
AT shanghongtao minimallyinvasivepercutaneousplateosteosynthesistechniquecombinedwithlockingcompressionplatesguidedbycarmxraymachineintreatmentoftibialmetaphysealfracturescurativeeffectandpostoperativecomplications