Analysis of Functionalized Ferromagnetic Memory Alloys from the Perspective of Developing a Medical Vascular Implant

Durable biocompatible metal vascular implants are still one of the significant challenges of contemporary medicine. This work presents the preparation of ferromagnetic biomaterials with shape memory in metal strips based on FePd (30 at% Pd) that is either not doped or doped with Ga and Mn, coated wi...

Descripción completa

Detalles Bibliográficos
Autores principales: Nan, Alexandrina, Turcu, Rodica, Tudoran, Cristian, Sofronie, Mihaela, Chiriac, Alexandru
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9002481/
https://www.ncbi.nlm.nih.gov/pubmed/35406270
http://dx.doi.org/10.3390/polym14071397
_version_ 1784685900406456320
author Nan, Alexandrina
Turcu, Rodica
Tudoran, Cristian
Sofronie, Mihaela
Chiriac, Alexandru
author_facet Nan, Alexandrina
Turcu, Rodica
Tudoran, Cristian
Sofronie, Mihaela
Chiriac, Alexandru
author_sort Nan, Alexandrina
collection PubMed
description Durable biocompatible metal vascular implants are still one of the significant challenges of contemporary medicine. This work presents the preparation of ferromagnetic biomaterials with shape memory in metal strips based on FePd (30 at% Pd) that is either not doped or doped with Ga and Mn, coated with poly(benzofuran-co-arylacetic acid) or polyglutamic acid. The coating of the metal strips with polymers was achieved after the metal surface had been previously treated with open-air cold plasma. The final functionalization was performed to induce anti-thrombogenic/thrombolytic properties in the resulting materials. SEM-EDX microscopy and X-ray photoelectron microscopy (XPS) determined the morphology and composition of the metal strips covered with polymers. In vitro tests of standardized thromboplastin time (PTT) and prothrombin time (PT) were performed to evaluate the thrombogenicity of these biofunctionalized materials for future possible monitoring of the implant in patients.
format Online
Article
Text
id pubmed-9002481
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-90024812022-04-13 Analysis of Functionalized Ferromagnetic Memory Alloys from the Perspective of Developing a Medical Vascular Implant Nan, Alexandrina Turcu, Rodica Tudoran, Cristian Sofronie, Mihaela Chiriac, Alexandru Polymers (Basel) Article Durable biocompatible metal vascular implants are still one of the significant challenges of contemporary medicine. This work presents the preparation of ferromagnetic biomaterials with shape memory in metal strips based on FePd (30 at% Pd) that is either not doped or doped with Ga and Mn, coated with poly(benzofuran-co-arylacetic acid) or polyglutamic acid. The coating of the metal strips with polymers was achieved after the metal surface had been previously treated with open-air cold plasma. The final functionalization was performed to induce anti-thrombogenic/thrombolytic properties in the resulting materials. SEM-EDX microscopy and X-ray photoelectron microscopy (XPS) determined the morphology and composition of the metal strips covered with polymers. In vitro tests of standardized thromboplastin time (PTT) and prothrombin time (PT) were performed to evaluate the thrombogenicity of these biofunctionalized materials for future possible monitoring of the implant in patients. MDPI 2022-03-29 /pmc/articles/PMC9002481/ /pubmed/35406270 http://dx.doi.org/10.3390/polym14071397 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Nan, Alexandrina
Turcu, Rodica
Tudoran, Cristian
Sofronie, Mihaela
Chiriac, Alexandru
Analysis of Functionalized Ferromagnetic Memory Alloys from the Perspective of Developing a Medical Vascular Implant
title Analysis of Functionalized Ferromagnetic Memory Alloys from the Perspective of Developing a Medical Vascular Implant
title_full Analysis of Functionalized Ferromagnetic Memory Alloys from the Perspective of Developing a Medical Vascular Implant
title_fullStr Analysis of Functionalized Ferromagnetic Memory Alloys from the Perspective of Developing a Medical Vascular Implant
title_full_unstemmed Analysis of Functionalized Ferromagnetic Memory Alloys from the Perspective of Developing a Medical Vascular Implant
title_short Analysis of Functionalized Ferromagnetic Memory Alloys from the Perspective of Developing a Medical Vascular Implant
title_sort analysis of functionalized ferromagnetic memory alloys from the perspective of developing a medical vascular implant
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9002481/
https://www.ncbi.nlm.nih.gov/pubmed/35406270
http://dx.doi.org/10.3390/polym14071397
work_keys_str_mv AT nanalexandrina analysisoffunctionalizedferromagneticmemoryalloysfromtheperspectiveofdevelopingamedicalvascularimplant
AT turcurodica analysisoffunctionalizedferromagneticmemoryalloysfromtheperspectiveofdevelopingamedicalvascularimplant
AT tudorancristian analysisoffunctionalizedferromagneticmemoryalloysfromtheperspectiveofdevelopingamedicalvascularimplant
AT sofroniemihaela analysisoffunctionalizedferromagneticmemoryalloysfromtheperspectiveofdevelopingamedicalvascularimplant
AT chiriacalexandru analysisoffunctionalizedferromagneticmemoryalloysfromtheperspectiveofdevelopingamedicalvascularimplant