Design and Reliability Analysis of a Novel Redundancy Topology Architecture
Topology architecture has a decisive influence on network reliability. In this paper, we design a novel redundancy topology and analyze the structural robustness, the number of redundant paths between two terminal nodes, and the reliability of the proposed topology by using natural connectivity and...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9002500/ https://www.ncbi.nlm.nih.gov/pubmed/35408197 http://dx.doi.org/10.3390/s22072582 |
_version_ | 1784685905134485504 |
---|---|
author | Li, Fei Liu, Wenyi Gao, Wanjia Liu, Yanfang Hu, Yanjun |
author_facet | Li, Fei Liu, Wenyi Gao, Wanjia Liu, Yanfang Hu, Yanjun |
author_sort | Li, Fei |
collection | PubMed |
description | Topology architecture has a decisive influence on network reliability. In this paper, we design a novel redundancy topology and analyze the structural robustness, the number of redundant paths between two terminal nodes, and the reliability of the proposed topology by using natural connectivity and time-independent and time-dependent terminal pair reliability, k-terminal reliability, and all-terminal reliability comprehensively and quantitatively, and we compare these measures of the proposed topology with AFDX in three scenarios. The evaluations show that in the structural robustness analysis, when no nodes are removed, the natural connectivity of the proposed topology with 10 nodes, 16 nodes, and 20 nodes is 77.8%, 26.95%, and 81.39% higher than that of AFDX, respectively. In the time-independent reliability analysis, when the link reliability is 0.9, terminal pair reliability of the proposed topology with 10 nodes, 16 nodes, and 20 nodes is 5.78%, 17.75%, and 34.65% higher than that of AFDX, respectively; k-terminal reliability is 10.04%, 31.97%, and 53.74% higher than that of AFDX, respectively; and all-terminal reliability is 29.36%, 74.37%, and 107.91% higher than that of AFDX, respectively. In the time-dependent reliability analysis, when the operating time is 8000 h, the terminal pair reliability of the proposed topology with 10 nodes, 16 nodes, and 20 nodes is 3.53%, 10.87%, and 21.08% higher than that of AFDX, respectively; the k-terminal reliability is 6.20%, 19.65%, and 32.58% higher than that of AFDX, respectively; and the all-terminal reliability is 18.25%, 45.04%, and 63.86% higher than that of AFDX, respectively. The proposed topology increases the redundant paths of data transmission. It ensures reliable data transmission and has high robustness and reliability. It provides a new idea for improving the reliability of industrial buses. |
format | Online Article Text |
id | pubmed-9002500 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-90025002022-04-13 Design and Reliability Analysis of a Novel Redundancy Topology Architecture Li, Fei Liu, Wenyi Gao, Wanjia Liu, Yanfang Hu, Yanjun Sensors (Basel) Article Topology architecture has a decisive influence on network reliability. In this paper, we design a novel redundancy topology and analyze the structural robustness, the number of redundant paths between two terminal nodes, and the reliability of the proposed topology by using natural connectivity and time-independent and time-dependent terminal pair reliability, k-terminal reliability, and all-terminal reliability comprehensively and quantitatively, and we compare these measures of the proposed topology with AFDX in three scenarios. The evaluations show that in the structural robustness analysis, when no nodes are removed, the natural connectivity of the proposed topology with 10 nodes, 16 nodes, and 20 nodes is 77.8%, 26.95%, and 81.39% higher than that of AFDX, respectively. In the time-independent reliability analysis, when the link reliability is 0.9, terminal pair reliability of the proposed topology with 10 nodes, 16 nodes, and 20 nodes is 5.78%, 17.75%, and 34.65% higher than that of AFDX, respectively; k-terminal reliability is 10.04%, 31.97%, and 53.74% higher than that of AFDX, respectively; and all-terminal reliability is 29.36%, 74.37%, and 107.91% higher than that of AFDX, respectively. In the time-dependent reliability analysis, when the operating time is 8000 h, the terminal pair reliability of the proposed topology with 10 nodes, 16 nodes, and 20 nodes is 3.53%, 10.87%, and 21.08% higher than that of AFDX, respectively; the k-terminal reliability is 6.20%, 19.65%, and 32.58% higher than that of AFDX, respectively; and the all-terminal reliability is 18.25%, 45.04%, and 63.86% higher than that of AFDX, respectively. The proposed topology increases the redundant paths of data transmission. It ensures reliable data transmission and has high robustness and reliability. It provides a new idea for improving the reliability of industrial buses. MDPI 2022-03-28 /pmc/articles/PMC9002500/ /pubmed/35408197 http://dx.doi.org/10.3390/s22072582 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Li, Fei Liu, Wenyi Gao, Wanjia Liu, Yanfang Hu, Yanjun Design and Reliability Analysis of a Novel Redundancy Topology Architecture |
title | Design and Reliability Analysis of a Novel Redundancy Topology Architecture |
title_full | Design and Reliability Analysis of a Novel Redundancy Topology Architecture |
title_fullStr | Design and Reliability Analysis of a Novel Redundancy Topology Architecture |
title_full_unstemmed | Design and Reliability Analysis of a Novel Redundancy Topology Architecture |
title_short | Design and Reliability Analysis of a Novel Redundancy Topology Architecture |
title_sort | design and reliability analysis of a novel redundancy topology architecture |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9002500/ https://www.ncbi.nlm.nih.gov/pubmed/35408197 http://dx.doi.org/10.3390/s22072582 |
work_keys_str_mv | AT lifei designandreliabilityanalysisofanovelredundancytopologyarchitecture AT liuwenyi designandreliabilityanalysisofanovelredundancytopologyarchitecture AT gaowanjia designandreliabilityanalysisofanovelredundancytopologyarchitecture AT liuyanfang designandreliabilityanalysisofanovelredundancytopologyarchitecture AT huyanjun designandreliabilityanalysisofanovelredundancytopologyarchitecture |