Resilient Consensus Control Design for DC Microgrids against False Data Injection Attacks Using a Distributed Bank of Sliding Mode Observers
This paper investigates the problem of false data injection attack (FDIA) detection in microgrids. The grid under study is a DC microgrid with distributed boost converters, where the false data are injected into the voltage data so as to investigate the effect of attacks. The proposed algorithm uses...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9002751/ https://www.ncbi.nlm.nih.gov/pubmed/35408256 http://dx.doi.org/10.3390/s22072644 |
_version_ | 1784685965084721152 |
---|---|
author | Barzegari, Yousof Zarei, Jafar Razavi-Far, Roozbeh Saif, Mehrdad Palade, Vasile |
author_facet | Barzegari, Yousof Zarei, Jafar Razavi-Far, Roozbeh Saif, Mehrdad Palade, Vasile |
author_sort | Barzegari, Yousof |
collection | PubMed |
description | This paper investigates the problem of false data injection attack (FDIA) detection in microgrids. The grid under study is a DC microgrid with distributed boost converters, where the false data are injected into the voltage data so as to investigate the effect of attacks. The proposed algorithm uses a bank of sliding mode observers that estimates the states of the neighbor agents. Each agent estimates the neighboring states and, according to the estimation and communication data, the detection mechanism reveals the presence of FDIA. The proposed control scheme provides resiliency to the system by replacing the conventional consensus rule with attack-resilient ones. In order to evaluate the efficiency of the proposed method, a real-time simulation with eight agents has been performed. Moreover, a verification experimental test with three boost converters has been utilized to confirm the simulation results. It is shown that the proposed algorithm is able to detect FDI attacks and it protects the consensus deviation against FDI attacks. |
format | Online Article Text |
id | pubmed-9002751 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-90027512022-04-13 Resilient Consensus Control Design for DC Microgrids against False Data Injection Attacks Using a Distributed Bank of Sliding Mode Observers Barzegari, Yousof Zarei, Jafar Razavi-Far, Roozbeh Saif, Mehrdad Palade, Vasile Sensors (Basel) Article This paper investigates the problem of false data injection attack (FDIA) detection in microgrids. The grid under study is a DC microgrid with distributed boost converters, where the false data are injected into the voltage data so as to investigate the effect of attacks. The proposed algorithm uses a bank of sliding mode observers that estimates the states of the neighbor agents. Each agent estimates the neighboring states and, according to the estimation and communication data, the detection mechanism reveals the presence of FDIA. The proposed control scheme provides resiliency to the system by replacing the conventional consensus rule with attack-resilient ones. In order to evaluate the efficiency of the proposed method, a real-time simulation with eight agents has been performed. Moreover, a verification experimental test with three boost converters has been utilized to confirm the simulation results. It is shown that the proposed algorithm is able to detect FDI attacks and it protects the consensus deviation against FDI attacks. MDPI 2022-03-30 /pmc/articles/PMC9002751/ /pubmed/35408256 http://dx.doi.org/10.3390/s22072644 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Barzegari, Yousof Zarei, Jafar Razavi-Far, Roozbeh Saif, Mehrdad Palade, Vasile Resilient Consensus Control Design for DC Microgrids against False Data Injection Attacks Using a Distributed Bank of Sliding Mode Observers |
title | Resilient Consensus Control Design for DC Microgrids against False Data Injection Attacks Using a Distributed Bank of Sliding Mode Observers |
title_full | Resilient Consensus Control Design for DC Microgrids against False Data Injection Attacks Using a Distributed Bank of Sliding Mode Observers |
title_fullStr | Resilient Consensus Control Design for DC Microgrids against False Data Injection Attacks Using a Distributed Bank of Sliding Mode Observers |
title_full_unstemmed | Resilient Consensus Control Design for DC Microgrids against False Data Injection Attacks Using a Distributed Bank of Sliding Mode Observers |
title_short | Resilient Consensus Control Design for DC Microgrids against False Data Injection Attacks Using a Distributed Bank of Sliding Mode Observers |
title_sort | resilient consensus control design for dc microgrids against false data injection attacks using a distributed bank of sliding mode observers |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9002751/ https://www.ncbi.nlm.nih.gov/pubmed/35408256 http://dx.doi.org/10.3390/s22072644 |
work_keys_str_mv | AT barzegariyousof resilientconsensuscontroldesignfordcmicrogridsagainstfalsedatainjectionattacksusingadistributedbankofslidingmodeobservers AT zareijafar resilientconsensuscontroldesignfordcmicrogridsagainstfalsedatainjectionattacksusingadistributedbankofslidingmodeobservers AT razavifarroozbeh resilientconsensuscontroldesignfordcmicrogridsagainstfalsedatainjectionattacksusingadistributedbankofslidingmodeobservers AT saifmehrdad resilientconsensuscontroldesignfordcmicrogridsagainstfalsedatainjectionattacksusingadistributedbankofslidingmodeobservers AT paladevasile resilientconsensuscontroldesignfordcmicrogridsagainstfalsedatainjectionattacksusingadistributedbankofslidingmodeobservers |