Feeding during Dialysis Increases Intradialytic Blood Pressure Variability and Reduces Dialysis Adequacy
Whether hemodialysis patients should be allowed or even encouraged to eat during dialysis remains a controversial topic. This cross-over study aimed to evaluate the impact of feeding during dialysis on intradialytic blood pressure (BP) profile and dialysis adequacy in 26 patients receiving thrice-we...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9002965/ https://www.ncbi.nlm.nih.gov/pubmed/35405970 http://dx.doi.org/10.3390/nu14071357 |
Sumario: | Whether hemodialysis patients should be allowed or even encouraged to eat during dialysis remains a controversial topic. This cross-over study aimed to evaluate the impact of feeding during dialysis on intradialytic blood pressure (BP) profile and dialysis adequacy in 26 patients receiving thrice-weekly, in-center hemodialysis. Over three consecutive mid-week dialysis sessions, intradialytic BP was monitored using the Mobil-O-Graph device (IEM, Stolberg, Germany). Blood samples were also obtained for the determination of the urea reduction ratio (URR). At baseline, patients underwent dialysis without the provision of a meal. In phases A and B, a meal with either high-protein (1.5 gr/kg of body weight) or low-protein (0.7 gr/kg of body weight) content was administered 1 h after the initiation of dialysis. The sequence of meals (high-protein and low-protein or vice versa) was randomized. Average intradialytic systolic BP (SBP) was similar on all three occasions. However, compared with baseline, the standard deviation (SD) (11.7 ± 4.1 vs. 15.6 ± 7.6 mmHg, p < 0.01), coefficient of variation (CV) (9.5 ± 3.7% vs. 12.4 ± 6.0%, p < 0.01) and average real variability (ARV) (9.4 ± 3.9 vs. 12.1 ± 5.2 mmHg, p < 0.01) of intradialytic SBP were higher in phase A. Similarly, compared with the baseline evaluation, all three indices of intradialytic SBP variability were higher in phase B (SD: 11.7 ± 4.1 vs. 14.1 ± 4.5 mmHg, p < 0.05; CV: 9.5 ± 3.7% vs. 11.1 ± 3.8%, p < 0.05; ARV: 9.4 ± 3.9 vs. 10.9 ± 3.9 mmHg, p < 0.05). Compared with dialysis without a meal, the consumption of a high-protein or low-protein meal resulted in a lower URR (73.4 ± 4.3% vs. 65.7 ± 10.7%, p < 0.001 in phase A and 73.4 ± 4.3% vs. 67.6 ± 4.3%, p < 0.001 in phase B, respectively). In conclusion, in the present study, feeding during dialysis was associated with higher intradialytic SBP variability and reduced adequacy of the delivered dialysis. |
---|