Mechanism of Magnetic Permeability Perturbation in Magnetizing-Based Eddy Current Nondestructive Testing
DC magnetization is generally considered to suppress the usual local magnetic permeability variation and increase the penetration depth for magnetizing-based eddy current testing (MB-ECT) of ferromagnetic materials. In fact, such simple explanations lead to rough nondestructive evaluation and cause...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9003470/ https://www.ncbi.nlm.nih.gov/pubmed/35408119 http://dx.doi.org/10.3390/s22072503 |
_version_ | 1784686141945937920 |
---|---|
author | Deng, Zhiyang Yu, Zhiheng Yuan, Zhongyu Song, Xiaochun Kang, Yihua |
author_facet | Deng, Zhiyang Yu, Zhiheng Yuan, Zhongyu Song, Xiaochun Kang, Yihua |
author_sort | Deng, Zhiyang |
collection | PubMed |
description | DC magnetization is generally considered to suppress the usual local magnetic permeability variation and increase the penetration depth for magnetizing-based eddy current testing (MB-ECT) of ferromagnetic materials. In fact, such simple explanations lead to rough nondestructive evaluation and cause new neglected non-uniform magnetic characteristics. Hence, the “perturbation” of the internal magnetic field variation is analyzed using a magnetic dipole model and the mechanism of magnetic permeability perturbation in MB-ECT is revealed. The theoretical analysis and simulations show that a significant permeability perturbation always appears around a defect and presents opposite features with strong and weak magnetization. Furthermore, experimental results indicate that the hidden signal component arising from the local permeability perturbation is critical for both far-side surface and near-side surface defects in the MB-ECT method. |
format | Online Article Text |
id | pubmed-9003470 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-90034702022-04-13 Mechanism of Magnetic Permeability Perturbation in Magnetizing-Based Eddy Current Nondestructive Testing Deng, Zhiyang Yu, Zhiheng Yuan, Zhongyu Song, Xiaochun Kang, Yihua Sensors (Basel) Article DC magnetization is generally considered to suppress the usual local magnetic permeability variation and increase the penetration depth for magnetizing-based eddy current testing (MB-ECT) of ferromagnetic materials. In fact, such simple explanations lead to rough nondestructive evaluation and cause new neglected non-uniform magnetic characteristics. Hence, the “perturbation” of the internal magnetic field variation is analyzed using a magnetic dipole model and the mechanism of magnetic permeability perturbation in MB-ECT is revealed. The theoretical analysis and simulations show that a significant permeability perturbation always appears around a defect and presents opposite features with strong and weak magnetization. Furthermore, experimental results indicate that the hidden signal component arising from the local permeability perturbation is critical for both far-side surface and near-side surface defects in the MB-ECT method. MDPI 2022-03-25 /pmc/articles/PMC9003470/ /pubmed/35408119 http://dx.doi.org/10.3390/s22072503 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Deng, Zhiyang Yu, Zhiheng Yuan, Zhongyu Song, Xiaochun Kang, Yihua Mechanism of Magnetic Permeability Perturbation in Magnetizing-Based Eddy Current Nondestructive Testing |
title | Mechanism of Magnetic Permeability Perturbation in Magnetizing-Based Eddy Current Nondestructive Testing |
title_full | Mechanism of Magnetic Permeability Perturbation in Magnetizing-Based Eddy Current Nondestructive Testing |
title_fullStr | Mechanism of Magnetic Permeability Perturbation in Magnetizing-Based Eddy Current Nondestructive Testing |
title_full_unstemmed | Mechanism of Magnetic Permeability Perturbation in Magnetizing-Based Eddy Current Nondestructive Testing |
title_short | Mechanism of Magnetic Permeability Perturbation in Magnetizing-Based Eddy Current Nondestructive Testing |
title_sort | mechanism of magnetic permeability perturbation in magnetizing-based eddy current nondestructive testing |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9003470/ https://www.ncbi.nlm.nih.gov/pubmed/35408119 http://dx.doi.org/10.3390/s22072503 |
work_keys_str_mv | AT dengzhiyang mechanismofmagneticpermeabilityperturbationinmagnetizingbasededdycurrentnondestructivetesting AT yuzhiheng mechanismofmagneticpermeabilityperturbationinmagnetizingbasededdycurrentnondestructivetesting AT yuanzhongyu mechanismofmagneticpermeabilityperturbationinmagnetizingbasededdycurrentnondestructivetesting AT songxiaochun mechanismofmagneticpermeabilityperturbationinmagnetizingbasededdycurrentnondestructivetesting AT kangyihua mechanismofmagneticpermeabilityperturbationinmagnetizingbasededdycurrentnondestructivetesting |