Mechanism of Magnetic Permeability Perturbation in Magnetizing-Based Eddy Current Nondestructive Testing

DC magnetization is generally considered to suppress the usual local magnetic permeability variation and increase the penetration depth for magnetizing-based eddy current testing (MB-ECT) of ferromagnetic materials. In fact, such simple explanations lead to rough nondestructive evaluation and cause...

Descripción completa

Detalles Bibliográficos
Autores principales: Deng, Zhiyang, Yu, Zhiheng, Yuan, Zhongyu, Song, Xiaochun, Kang, Yihua
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9003470/
https://www.ncbi.nlm.nih.gov/pubmed/35408119
http://dx.doi.org/10.3390/s22072503
_version_ 1784686141945937920
author Deng, Zhiyang
Yu, Zhiheng
Yuan, Zhongyu
Song, Xiaochun
Kang, Yihua
author_facet Deng, Zhiyang
Yu, Zhiheng
Yuan, Zhongyu
Song, Xiaochun
Kang, Yihua
author_sort Deng, Zhiyang
collection PubMed
description DC magnetization is generally considered to suppress the usual local magnetic permeability variation and increase the penetration depth for magnetizing-based eddy current testing (MB-ECT) of ferromagnetic materials. In fact, such simple explanations lead to rough nondestructive evaluation and cause new neglected non-uniform magnetic characteristics. Hence, the “perturbation” of the internal magnetic field variation is analyzed using a magnetic dipole model and the mechanism of magnetic permeability perturbation in MB-ECT is revealed. The theoretical analysis and simulations show that a significant permeability perturbation always appears around a defect and presents opposite features with strong and weak magnetization. Furthermore, experimental results indicate that the hidden signal component arising from the local permeability perturbation is critical for both far-side surface and near-side surface defects in the MB-ECT method.
format Online
Article
Text
id pubmed-9003470
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-90034702022-04-13 Mechanism of Magnetic Permeability Perturbation in Magnetizing-Based Eddy Current Nondestructive Testing Deng, Zhiyang Yu, Zhiheng Yuan, Zhongyu Song, Xiaochun Kang, Yihua Sensors (Basel) Article DC magnetization is generally considered to suppress the usual local magnetic permeability variation and increase the penetration depth for magnetizing-based eddy current testing (MB-ECT) of ferromagnetic materials. In fact, such simple explanations lead to rough nondestructive evaluation and cause new neglected non-uniform magnetic characteristics. Hence, the “perturbation” of the internal magnetic field variation is analyzed using a magnetic dipole model and the mechanism of magnetic permeability perturbation in MB-ECT is revealed. The theoretical analysis and simulations show that a significant permeability perturbation always appears around a defect and presents opposite features with strong and weak magnetization. Furthermore, experimental results indicate that the hidden signal component arising from the local permeability perturbation is critical for both far-side surface and near-side surface defects in the MB-ECT method. MDPI 2022-03-25 /pmc/articles/PMC9003470/ /pubmed/35408119 http://dx.doi.org/10.3390/s22072503 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Deng, Zhiyang
Yu, Zhiheng
Yuan, Zhongyu
Song, Xiaochun
Kang, Yihua
Mechanism of Magnetic Permeability Perturbation in Magnetizing-Based Eddy Current Nondestructive Testing
title Mechanism of Magnetic Permeability Perturbation in Magnetizing-Based Eddy Current Nondestructive Testing
title_full Mechanism of Magnetic Permeability Perturbation in Magnetizing-Based Eddy Current Nondestructive Testing
title_fullStr Mechanism of Magnetic Permeability Perturbation in Magnetizing-Based Eddy Current Nondestructive Testing
title_full_unstemmed Mechanism of Magnetic Permeability Perturbation in Magnetizing-Based Eddy Current Nondestructive Testing
title_short Mechanism of Magnetic Permeability Perturbation in Magnetizing-Based Eddy Current Nondestructive Testing
title_sort mechanism of magnetic permeability perturbation in magnetizing-based eddy current nondestructive testing
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9003470/
https://www.ncbi.nlm.nih.gov/pubmed/35408119
http://dx.doi.org/10.3390/s22072503
work_keys_str_mv AT dengzhiyang mechanismofmagneticpermeabilityperturbationinmagnetizingbasededdycurrentnondestructivetesting
AT yuzhiheng mechanismofmagneticpermeabilityperturbationinmagnetizingbasededdycurrentnondestructivetesting
AT yuanzhongyu mechanismofmagneticpermeabilityperturbationinmagnetizingbasededdycurrentnondestructivetesting
AT songxiaochun mechanismofmagneticpermeabilityperturbationinmagnetizingbasededdycurrentnondestructivetesting
AT kangyihua mechanismofmagneticpermeabilityperturbationinmagnetizingbasededdycurrentnondestructivetesting