Cargando…

A Systematic Review of the Transthoracic Impedance during Cardiac Defibrillation

For cardiac defibrillator testing and design purposes, the range and limits of the human TTI is of high interest. Potential influencing factors regarding the electronic configurations, the electrode/tissue interface and patient characteristics were identified and analyzed. A literature survey based...

Descripción completa

Detalles Bibliográficos
Autores principales: Heyer, Yasmine, Baumgartner, Daniela, Baumgartner, Christian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9003563/
https://www.ncbi.nlm.nih.gov/pubmed/35408422
http://dx.doi.org/10.3390/s22072808
_version_ 1784686159571451904
author Heyer, Yasmine
Baumgartner, Daniela
Baumgartner, Christian
author_facet Heyer, Yasmine
Baumgartner, Daniela
Baumgartner, Christian
author_sort Heyer, Yasmine
collection PubMed
description For cardiac defibrillator testing and design purposes, the range and limits of the human TTI is of high interest. Potential influencing factors regarding the electronic configurations, the electrode/tissue interface and patient characteristics were identified and analyzed. A literature survey based on 71 selected articles was used to review and assess human TTI and the influencing factors found. The human TTI extended from 12 to 212 [Formula: see text] in the literature selected. Excluding outliers and pediatric measurements, the mean TTI recordings ranged from 51 to 112 [Formula: see text] with an average TTI of 76.7 [Formula: see text] under normal distribution. The wide range of human impedance can be attributed to 12 different influencing factors, including shock waveforms and protocols, coupling devices, electrode size and pressure, electrode position, patient age, gender, body dimensions, respiration and lung volume, blood hemoglobin saturation and different pathologies. The coupling device, electrode size and electrode pressure have the greatest influence on TTI.
format Online
Article
Text
id pubmed-9003563
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-90035632022-04-13 A Systematic Review of the Transthoracic Impedance during Cardiac Defibrillation Heyer, Yasmine Baumgartner, Daniela Baumgartner, Christian Sensors (Basel) Systematic Review For cardiac defibrillator testing and design purposes, the range and limits of the human TTI is of high interest. Potential influencing factors regarding the electronic configurations, the electrode/tissue interface and patient characteristics were identified and analyzed. A literature survey based on 71 selected articles was used to review and assess human TTI and the influencing factors found. The human TTI extended from 12 to 212 [Formula: see text] in the literature selected. Excluding outliers and pediatric measurements, the mean TTI recordings ranged from 51 to 112 [Formula: see text] with an average TTI of 76.7 [Formula: see text] under normal distribution. The wide range of human impedance can be attributed to 12 different influencing factors, including shock waveforms and protocols, coupling devices, electrode size and pressure, electrode position, patient age, gender, body dimensions, respiration and lung volume, blood hemoglobin saturation and different pathologies. The coupling device, electrode size and electrode pressure have the greatest influence on TTI. MDPI 2022-04-06 /pmc/articles/PMC9003563/ /pubmed/35408422 http://dx.doi.org/10.3390/s22072808 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Systematic Review
Heyer, Yasmine
Baumgartner, Daniela
Baumgartner, Christian
A Systematic Review of the Transthoracic Impedance during Cardiac Defibrillation
title A Systematic Review of the Transthoracic Impedance during Cardiac Defibrillation
title_full A Systematic Review of the Transthoracic Impedance during Cardiac Defibrillation
title_fullStr A Systematic Review of the Transthoracic Impedance during Cardiac Defibrillation
title_full_unstemmed A Systematic Review of the Transthoracic Impedance during Cardiac Defibrillation
title_short A Systematic Review of the Transthoracic Impedance during Cardiac Defibrillation
title_sort systematic review of the transthoracic impedance during cardiac defibrillation
topic Systematic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9003563/
https://www.ncbi.nlm.nih.gov/pubmed/35408422
http://dx.doi.org/10.3390/s22072808
work_keys_str_mv AT heyeryasmine asystematicreviewofthetransthoracicimpedanceduringcardiacdefibrillation
AT baumgartnerdaniela asystematicreviewofthetransthoracicimpedanceduringcardiacdefibrillation
AT baumgartnerchristian asystematicreviewofthetransthoracicimpedanceduringcardiacdefibrillation
AT heyeryasmine systematicreviewofthetransthoracicimpedanceduringcardiacdefibrillation
AT baumgartnerdaniela systematicreviewofthetransthoracicimpedanceduringcardiacdefibrillation
AT baumgartnerchristian systematicreviewofthetransthoracicimpedanceduringcardiacdefibrillation