Cargando…
Open Repair of Large Hepatic Artery Pseudoaneurysm Without Collateral Circulation: A Case Report
Hepatic artery pseudoaneurysm is a rare arterial disease. This case report describes a patient with hepatic artery pseudoaneurysm who presented with recurrent epigastric pain over a 4-month period. Computed tomography angiography (CTA) showed aneurysmal enlargement of the hepatic artery measuring 55...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9005641/ https://www.ncbi.nlm.nih.gov/pubmed/35433820 http://dx.doi.org/10.3389/fsurg.2022.791553 |
_version_ | 1784686501260427264 |
---|---|
author | Wen, Xin Chen, Xiyang Zhao, Jichun Luo, Xin Guo, Qiang Du, Xiaojiong Yuan, Ding Huang, Bin |
author_facet | Wen, Xin Chen, Xiyang Zhao, Jichun Luo, Xin Guo, Qiang Du, Xiaojiong Yuan, Ding Huang, Bin |
author_sort | Wen, Xin |
collection | PubMed |
description | Hepatic artery pseudoaneurysm is a rare arterial disease. This case report describes a patient with hepatic artery pseudoaneurysm who presented with recurrent epigastric pain over a 4-month period. Computed tomography angiography (CTA) showed aneurysmal enlargement of the hepatic artery measuring 55 mm × 46 mm. The angiographic information is as follows: (1) the common hepatic artery originated from the superior mesenteric artery; (2) the proper hepatic artery originated from the common hepatic artery; (3) the proper hepatic aneurysmal disease had no collateral circulation. After careful consideration, the patient underwent an open surgical repair (OSR). The patient recovered well without any associated complications. The 1-year follow-up of patients did not reveal any relevant complications. The treatment choice, puzzles, and reflections of this case are all discussed in this article. |
format | Online Article Text |
id | pubmed-9005641 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-90056412022-04-14 Open Repair of Large Hepatic Artery Pseudoaneurysm Without Collateral Circulation: A Case Report Wen, Xin Chen, Xiyang Zhao, Jichun Luo, Xin Guo, Qiang Du, Xiaojiong Yuan, Ding Huang, Bin Front Surg Surgery Hepatic artery pseudoaneurysm is a rare arterial disease. This case report describes a patient with hepatic artery pseudoaneurysm who presented with recurrent epigastric pain over a 4-month period. Computed tomography angiography (CTA) showed aneurysmal enlargement of the hepatic artery measuring 55 mm × 46 mm. The angiographic information is as follows: (1) the common hepatic artery originated from the superior mesenteric artery; (2) the proper hepatic artery originated from the common hepatic artery; (3) the proper hepatic aneurysmal disease had no collateral circulation. After careful consideration, the patient underwent an open surgical repair (OSR). The patient recovered well without any associated complications. The 1-year follow-up of patients did not reveal any relevant complications. The treatment choice, puzzles, and reflections of this case are all discussed in this article. Frontiers Media S.A. 2022-03-30 /pmc/articles/PMC9005641/ /pubmed/35433820 http://dx.doi.org/10.3389/fsurg.2022.791553 Text en Copyright © 2022 Wen, Chen, Zhao, Luo, Guo, Du, Yuan and Huang. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Surgery Wen, Xin Chen, Xiyang Zhao, Jichun Luo, Xin Guo, Qiang Du, Xiaojiong Yuan, Ding Huang, Bin Open Repair of Large Hepatic Artery Pseudoaneurysm Without Collateral Circulation: A Case Report |
title | Open Repair of Large Hepatic Artery Pseudoaneurysm Without Collateral Circulation: A Case Report |
title_full | Open Repair of Large Hepatic Artery Pseudoaneurysm Without Collateral Circulation: A Case Report |
title_fullStr | Open Repair of Large Hepatic Artery Pseudoaneurysm Without Collateral Circulation: A Case Report |
title_full_unstemmed | Open Repair of Large Hepatic Artery Pseudoaneurysm Without Collateral Circulation: A Case Report |
title_short | Open Repair of Large Hepatic Artery Pseudoaneurysm Without Collateral Circulation: A Case Report |
title_sort | open repair of large hepatic artery pseudoaneurysm without collateral circulation: a case report |
topic | Surgery |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9005641/ https://www.ncbi.nlm.nih.gov/pubmed/35433820 http://dx.doi.org/10.3389/fsurg.2022.791553 |
work_keys_str_mv | AT wenxin openrepairoflargehepaticarterypseudoaneurysmwithoutcollateralcirculationacasereport AT chenxiyang openrepairoflargehepaticarterypseudoaneurysmwithoutcollateralcirculationacasereport AT zhaojichun openrepairoflargehepaticarterypseudoaneurysmwithoutcollateralcirculationacasereport AT luoxin openrepairoflargehepaticarterypseudoaneurysmwithoutcollateralcirculationacasereport AT guoqiang openrepairoflargehepaticarterypseudoaneurysmwithoutcollateralcirculationacasereport AT duxiaojiong openrepairoflargehepaticarterypseudoaneurysmwithoutcollateralcirculationacasereport AT yuanding openrepairoflargehepaticarterypseudoaneurysmwithoutcollateralcirculationacasereport AT huangbin openrepairoflargehepaticarterypseudoaneurysmwithoutcollateralcirculationacasereport |