Cargando…

Treatment of hand and finger fractures with the Stryker Hand Plating System

Objectives: 10% of all fractures occur in the fingers and metacarpal region. Early mobilization with preservation of grip function is the goal of any therapy for these injuries. Osteosyntheses with plates are used in complex fractures that do not allow any other treatment. The aim of this retrospect...

Descripción completa

Detalles Bibliográficos
Autores principales: Biehl, Christoph, Stötzel, Sabine, Schock, Lydia, Szalay, Gabor, Heiss, Christian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: German Medical Science GMS Publishing House 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9006317/
https://www.ncbi.nlm.nih.gov/pubmed/35465637
http://dx.doi.org/10.3205/000305
_version_ 1784686640582623232
author Biehl, Christoph
Stötzel, Sabine
Schock, Lydia
Szalay, Gabor
Heiss, Christian
author_facet Biehl, Christoph
Stötzel, Sabine
Schock, Lydia
Szalay, Gabor
Heiss, Christian
author_sort Biehl, Christoph
collection PubMed
description Objectives: 10% of all fractures occur in the fingers and metacarpal region. Early mobilization with preservation of grip function is the goal of any therapy for these injuries. Osteosyntheses with plates are used in complex fractures that do not allow any other treatment. The aim of this retrospective study was to evaluate the performance and safety of the Stryker Hand System. Patients and methods: Between 2010 and 2019, 190 patients underwent surgical treatment with plates for fractures of the fingers and metacarpal region. Of these, 140 operations could be analyzed according to the inclusion criteria based on clinical and radiological parameters. Results: Three-quarters of the patients were male. The mean age at the time of surgery was 39.3±16 years. Falling was the leading cause for hand fractures, and the most common were fractures of the shaft (>52%). More than 15% were complex hand injuries with more than one fractured finger. The majority of patients were healthy non-smokers without systemic diseases and relevant medical history. Conclusion: The Stryker Finger Plates are safe implants with good results that are consistent with those reported in the literature. The trend is also toward stable-angle implants for fracture treatment of the finger, in order to enable the earliest possible functional, safe mobilization. Level of Evidence: Level: IV; outcome-study, retrospective
format Online
Article
Text
id pubmed-9006317
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher German Medical Science GMS Publishing House
record_format MEDLINE/PubMed
spelling pubmed-90063172022-04-21 Treatment of hand and finger fractures with the Stryker Hand Plating System Biehl, Christoph Stötzel, Sabine Schock, Lydia Szalay, Gabor Heiss, Christian Ger Med Sci Article Objectives: 10% of all fractures occur in the fingers and metacarpal region. Early mobilization with preservation of grip function is the goal of any therapy for these injuries. Osteosyntheses with plates are used in complex fractures that do not allow any other treatment. The aim of this retrospective study was to evaluate the performance and safety of the Stryker Hand System. Patients and methods: Between 2010 and 2019, 190 patients underwent surgical treatment with plates for fractures of the fingers and metacarpal region. Of these, 140 operations could be analyzed according to the inclusion criteria based on clinical and radiological parameters. Results: Three-quarters of the patients were male. The mean age at the time of surgery was 39.3±16 years. Falling was the leading cause for hand fractures, and the most common were fractures of the shaft (>52%). More than 15% were complex hand injuries with more than one fractured finger. The majority of patients were healthy non-smokers without systemic diseases and relevant medical history. Conclusion: The Stryker Finger Plates are safe implants with good results that are consistent with those reported in the literature. The trend is also toward stable-angle implants for fracture treatment of the finger, in order to enable the earliest possible functional, safe mobilization. Level of Evidence: Level: IV; outcome-study, retrospective German Medical Science GMS Publishing House 2022-03-31 /pmc/articles/PMC9006317/ /pubmed/35465637 http://dx.doi.org/10.3205/000305 Text en Copyright © 2022 Biehl et al. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution 4.0 License. See license information at http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Biehl, Christoph
Stötzel, Sabine
Schock, Lydia
Szalay, Gabor
Heiss, Christian
Treatment of hand and finger fractures with the Stryker Hand Plating System
title Treatment of hand and finger fractures with the Stryker Hand Plating System
title_full Treatment of hand and finger fractures with the Stryker Hand Plating System
title_fullStr Treatment of hand and finger fractures with the Stryker Hand Plating System
title_full_unstemmed Treatment of hand and finger fractures with the Stryker Hand Plating System
title_short Treatment of hand and finger fractures with the Stryker Hand Plating System
title_sort treatment of hand and finger fractures with the stryker hand plating system
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9006317/
https://www.ncbi.nlm.nih.gov/pubmed/35465637
http://dx.doi.org/10.3205/000305
work_keys_str_mv AT biehlchristoph treatmentofhandandfingerfractureswiththestrykerhandplatingsystem
AT stotzelsabine treatmentofhandandfingerfractureswiththestrykerhandplatingsystem
AT schocklydia treatmentofhandandfingerfractureswiththestrykerhandplatingsystem
AT szalaygabor treatmentofhandandfingerfractureswiththestrykerhandplatingsystem
AT heisschristian treatmentofhandandfingerfractureswiththestrykerhandplatingsystem