Cargando…
Intraoperative optical coherence tomography (I-OCT) assisted passage of the encircling element during retinal detachment surgery
Objective: To describe the role of microscope integrated optical tomography (Mi-OCT) in passage of the encircling element during retinal detachment surgery. Materials and methods: Mi-OCT was switched on while passing scleral anchoring sutures to secure the encircling element. The depth of the suture...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
German Medical Science GMS Publishing House
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9006424/ https://www.ncbi.nlm.nih.gov/pubmed/35465300 http://dx.doi.org/10.3205/oc000197 |
_version_ | 1784686662962380800 |
---|---|
author | Markan, Ashish Gupta, Nikita Tigari, Basavaraj Singh, Ramandeep Dogra, Mohit |
author_facet | Markan, Ashish Gupta, Nikita Tigari, Basavaraj Singh, Ramandeep Dogra, Mohit |
author_sort | Markan, Ashish |
collection | PubMed |
description | Objective: To describe the role of microscope integrated optical tomography (Mi-OCT) in passage of the encircling element during retinal detachment surgery. Materials and methods: Mi-OCT was switched on while passing scleral anchoring sutures to secure the encircling element. The depth of the suture tract was seen in real time while the needle was passed through the sclera. The amount of scleral intend achieved was assessed using Mi-OCT at the end of the surgery. Results: The depth of needle tract through the sclera and the amount of scleral indentation achieved while tying the sutures could be successfully analyzed using Mi-OCT. Conclusion: Mi-OCT can be used as an adjunct while training vitreoretinal fellows and trainees in surgical procedures like passage of scleral sutures for anchoring the encircling element. |
format | Online Article Text |
id | pubmed-9006424 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | German Medical Science GMS Publishing House |
record_format | MEDLINE/PubMed |
spelling | pubmed-90064242022-04-21 Intraoperative optical coherence tomography (I-OCT) assisted passage of the encircling element during retinal detachment surgery Markan, Ashish Gupta, Nikita Tigari, Basavaraj Singh, Ramandeep Dogra, Mohit GMS Ophthalmol Cases Article Objective: To describe the role of microscope integrated optical tomography (Mi-OCT) in passage of the encircling element during retinal detachment surgery. Materials and methods: Mi-OCT was switched on while passing scleral anchoring sutures to secure the encircling element. The depth of the suture tract was seen in real time while the needle was passed through the sclera. The amount of scleral intend achieved was assessed using Mi-OCT at the end of the surgery. Results: The depth of needle tract through the sclera and the amount of scleral indentation achieved while tying the sutures could be successfully analyzed using Mi-OCT. Conclusion: Mi-OCT can be used as an adjunct while training vitreoretinal fellows and trainees in surgical procedures like passage of scleral sutures for anchoring the encircling element. German Medical Science GMS Publishing House 2022-04-01 /pmc/articles/PMC9006424/ /pubmed/35465300 http://dx.doi.org/10.3205/oc000197 Text en Copyright © 2022 Markan et al. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution 4.0 License. See license information at http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Markan, Ashish Gupta, Nikita Tigari, Basavaraj Singh, Ramandeep Dogra, Mohit Intraoperative optical coherence tomography (I-OCT) assisted passage of the encircling element during retinal detachment surgery |
title | Intraoperative optical coherence tomography (I-OCT) assisted passage of the encircling element during retinal detachment surgery |
title_full | Intraoperative optical coherence tomography (I-OCT) assisted passage of the encircling element during retinal detachment surgery |
title_fullStr | Intraoperative optical coherence tomography (I-OCT) assisted passage of the encircling element during retinal detachment surgery |
title_full_unstemmed | Intraoperative optical coherence tomography (I-OCT) assisted passage of the encircling element during retinal detachment surgery |
title_short | Intraoperative optical coherence tomography (I-OCT) assisted passage of the encircling element during retinal detachment surgery |
title_sort | intraoperative optical coherence tomography (i-oct) assisted passage of the encircling element during retinal detachment surgery |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9006424/ https://www.ncbi.nlm.nih.gov/pubmed/35465300 http://dx.doi.org/10.3205/oc000197 |
work_keys_str_mv | AT markanashish intraoperativeopticalcoherencetomographyioctassistedpassageoftheencirclingelementduringretinaldetachmentsurgery AT guptanikita intraoperativeopticalcoherencetomographyioctassistedpassageoftheencirclingelementduringretinaldetachmentsurgery AT tigaribasavaraj intraoperativeopticalcoherencetomographyioctassistedpassageoftheencirclingelementduringretinaldetachmentsurgery AT singhramandeep intraoperativeopticalcoherencetomographyioctassistedpassageoftheencirclingelementduringretinaldetachmentsurgery AT dogramohit intraoperativeopticalcoherencetomographyioctassistedpassageoftheencirclingelementduringretinaldetachmentsurgery |