Cargando…

Intraoperative optical coherence tomography (I-OCT) assisted passage of the encircling element during retinal detachment surgery

Objective: To describe the role of microscope integrated optical tomography (Mi-OCT) in passage of the encircling element during retinal detachment surgery. Materials and methods: Mi-OCT was switched on while passing scleral anchoring sutures to secure the encircling element. The depth of the suture...

Descripción completa

Detalles Bibliográficos
Autores principales: Markan, Ashish, Gupta, Nikita, Tigari, Basavaraj, Singh, Ramandeep, Dogra, Mohit
Formato: Online Artículo Texto
Lenguaje:English
Publicado: German Medical Science GMS Publishing House 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9006424/
https://www.ncbi.nlm.nih.gov/pubmed/35465300
http://dx.doi.org/10.3205/oc000197
_version_ 1784686662962380800
author Markan, Ashish
Gupta, Nikita
Tigari, Basavaraj
Singh, Ramandeep
Dogra, Mohit
author_facet Markan, Ashish
Gupta, Nikita
Tigari, Basavaraj
Singh, Ramandeep
Dogra, Mohit
author_sort Markan, Ashish
collection PubMed
description Objective: To describe the role of microscope integrated optical tomography (Mi-OCT) in passage of the encircling element during retinal detachment surgery. Materials and methods: Mi-OCT was switched on while passing scleral anchoring sutures to secure the encircling element. The depth of the suture tract was seen in real time while the needle was passed through the sclera. The amount of scleral intend achieved was assessed using Mi-OCT at the end of the surgery. Results: The depth of needle tract through the sclera and the amount of scleral indentation achieved while tying the sutures could be successfully analyzed using Mi-OCT. Conclusion: Mi-OCT can be used as an adjunct while training vitreoretinal fellows and trainees in surgical procedures like passage of scleral sutures for anchoring the encircling element.
format Online
Article
Text
id pubmed-9006424
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher German Medical Science GMS Publishing House
record_format MEDLINE/PubMed
spelling pubmed-90064242022-04-21 Intraoperative optical coherence tomography (I-OCT) assisted passage of the encircling element during retinal detachment surgery Markan, Ashish Gupta, Nikita Tigari, Basavaraj Singh, Ramandeep Dogra, Mohit GMS Ophthalmol Cases Article Objective: To describe the role of microscope integrated optical tomography (Mi-OCT) in passage of the encircling element during retinal detachment surgery. Materials and methods: Mi-OCT was switched on while passing scleral anchoring sutures to secure the encircling element. The depth of the suture tract was seen in real time while the needle was passed through the sclera. The amount of scleral intend achieved was assessed using Mi-OCT at the end of the surgery. Results: The depth of needle tract through the sclera and the amount of scleral indentation achieved while tying the sutures could be successfully analyzed using Mi-OCT. Conclusion: Mi-OCT can be used as an adjunct while training vitreoretinal fellows and trainees in surgical procedures like passage of scleral sutures for anchoring the encircling element. German Medical Science GMS Publishing House 2022-04-01 /pmc/articles/PMC9006424/ /pubmed/35465300 http://dx.doi.org/10.3205/oc000197 Text en Copyright © 2022 Markan et al. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution 4.0 License. See license information at http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Markan, Ashish
Gupta, Nikita
Tigari, Basavaraj
Singh, Ramandeep
Dogra, Mohit
Intraoperative optical coherence tomography (I-OCT) assisted passage of the encircling element during retinal detachment surgery
title Intraoperative optical coherence tomography (I-OCT) assisted passage of the encircling element during retinal detachment surgery
title_full Intraoperative optical coherence tomography (I-OCT) assisted passage of the encircling element during retinal detachment surgery
title_fullStr Intraoperative optical coherence tomography (I-OCT) assisted passage of the encircling element during retinal detachment surgery
title_full_unstemmed Intraoperative optical coherence tomography (I-OCT) assisted passage of the encircling element during retinal detachment surgery
title_short Intraoperative optical coherence tomography (I-OCT) assisted passage of the encircling element during retinal detachment surgery
title_sort intraoperative optical coherence tomography (i-oct) assisted passage of the encircling element during retinal detachment surgery
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9006424/
https://www.ncbi.nlm.nih.gov/pubmed/35465300
http://dx.doi.org/10.3205/oc000197
work_keys_str_mv AT markanashish intraoperativeopticalcoherencetomographyioctassistedpassageoftheencirclingelementduringretinaldetachmentsurgery
AT guptanikita intraoperativeopticalcoherencetomographyioctassistedpassageoftheencirclingelementduringretinaldetachmentsurgery
AT tigaribasavaraj intraoperativeopticalcoherencetomographyioctassistedpassageoftheencirclingelementduringretinaldetachmentsurgery
AT singhramandeep intraoperativeopticalcoherencetomographyioctassistedpassageoftheencirclingelementduringretinaldetachmentsurgery
AT dogramohit intraoperativeopticalcoherencetomographyioctassistedpassageoftheencirclingelementduringretinaldetachmentsurgery