Cargando…

The effect of transverse ocular magnification adjustment on macular thickness profile in different refractive errors in community-based adults

PURPOSE: Changes in retinal thickness are common in various ocular diseases. Transverse magnification due to differing ocular biometrics, in particular axial length, affects measurement of retinal thickness in different regions. This study evaluated the effect of axial length and refractive error on...

Descripción completa

Detalles Bibliográficos
Autores principales: Niyazmand, Hamed, Lingham, Gareth, Sanfilippo, Paul G., Blaszkowska, Magdalena, Franchina, Maria, Yazar, Seyhan, Alonso-Caneiro, David, Mackey, David A., Lee, Samantha Sze-Yee
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9007368/
https://www.ncbi.nlm.nih.gov/pubmed/35417477
http://dx.doi.org/10.1371/journal.pone.0266909
_version_ 1784686832769826816
author Niyazmand, Hamed
Lingham, Gareth
Sanfilippo, Paul G.
Blaszkowska, Magdalena
Franchina, Maria
Yazar, Seyhan
Alonso-Caneiro, David
Mackey, David A.
Lee, Samantha Sze-Yee
author_facet Niyazmand, Hamed
Lingham, Gareth
Sanfilippo, Paul G.
Blaszkowska, Magdalena
Franchina, Maria
Yazar, Seyhan
Alonso-Caneiro, David
Mackey, David A.
Lee, Samantha Sze-Yee
author_sort Niyazmand, Hamed
collection PubMed
description PURPOSE: Changes in retinal thickness are common in various ocular diseases. Transverse magnification due to differing ocular biometrics, in particular axial length, affects measurement of retinal thickness in different regions. This study evaluated the effect of axial length and refractive error on measured macular thickness in two community-based cohorts of healthy young adults. METHODS: A total of 2160 eyes of 1247 community-based participants (18–30 years; 23.4% myopes, mean axial length = 23.6mm) were included in this analysis. Macular thickness measurements were obtained using a spectral-domain optical coherence tomography (which assumes an axial length of 24.385mm). Using a custom program, retinal thickness data were extracted at the 9 Early Treatment of Diabetic Retinopathy Study (ETDRS) regions with and without correction for transverse magnificent effects, with the corrected measurements adjusting according to the participant’s axial length. Linear mixed models were used to analyse the effect of correction and its interaction with axial length or refractive group on retinal thickness. RESULTS: The raw measures (uncorrected for axial length) underestimated the true retinal thickness at the central macula, while overestimating at most non-central macular regions. There was an axial length by correction interaction effect in all but the nasal regions (all p<0.05). For each 1mm increase in axial length, the central macular thickness is overestimated by 2.7–2.9μm while thicknesses at other regions were underestimated by 0.2–4.1μm. Based on the raw thickness measurements, myopes have thinner retinas than non-myopes at most non-central macular. However, this difference was no longer significant when the corrected data was used. CONCLUSION: In a community-based sample, the raw measurements underestimate the retinal thickness at the central macula and overestimate the retinal thickness at non-central regions of the ETDRS grid. The effect of axial length and refractive error on retinal thickness is reduced after correcting for transverse magnification effects resulting from axial length differences.
format Online
Article
Text
id pubmed-9007368
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-90073682022-04-14 The effect of transverse ocular magnification adjustment on macular thickness profile in different refractive errors in community-based adults Niyazmand, Hamed Lingham, Gareth Sanfilippo, Paul G. Blaszkowska, Magdalena Franchina, Maria Yazar, Seyhan Alonso-Caneiro, David Mackey, David A. Lee, Samantha Sze-Yee PLoS One Research Article PURPOSE: Changes in retinal thickness are common in various ocular diseases. Transverse magnification due to differing ocular biometrics, in particular axial length, affects measurement of retinal thickness in different regions. This study evaluated the effect of axial length and refractive error on measured macular thickness in two community-based cohorts of healthy young adults. METHODS: A total of 2160 eyes of 1247 community-based participants (18–30 years; 23.4% myopes, mean axial length = 23.6mm) were included in this analysis. Macular thickness measurements were obtained using a spectral-domain optical coherence tomography (which assumes an axial length of 24.385mm). Using a custom program, retinal thickness data were extracted at the 9 Early Treatment of Diabetic Retinopathy Study (ETDRS) regions with and without correction for transverse magnificent effects, with the corrected measurements adjusting according to the participant’s axial length. Linear mixed models were used to analyse the effect of correction and its interaction with axial length or refractive group on retinal thickness. RESULTS: The raw measures (uncorrected for axial length) underestimated the true retinal thickness at the central macula, while overestimating at most non-central macular regions. There was an axial length by correction interaction effect in all but the nasal regions (all p<0.05). For each 1mm increase in axial length, the central macular thickness is overestimated by 2.7–2.9μm while thicknesses at other regions were underestimated by 0.2–4.1μm. Based on the raw thickness measurements, myopes have thinner retinas than non-myopes at most non-central macular. However, this difference was no longer significant when the corrected data was used. CONCLUSION: In a community-based sample, the raw measurements underestimate the retinal thickness at the central macula and overestimate the retinal thickness at non-central regions of the ETDRS grid. The effect of axial length and refractive error on retinal thickness is reduced after correcting for transverse magnification effects resulting from axial length differences. Public Library of Science 2022-04-13 /pmc/articles/PMC9007368/ /pubmed/35417477 http://dx.doi.org/10.1371/journal.pone.0266909 Text en © 2022 Niyazmand et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Niyazmand, Hamed
Lingham, Gareth
Sanfilippo, Paul G.
Blaszkowska, Magdalena
Franchina, Maria
Yazar, Seyhan
Alonso-Caneiro, David
Mackey, David A.
Lee, Samantha Sze-Yee
The effect of transverse ocular magnification adjustment on macular thickness profile in different refractive errors in community-based adults
title The effect of transverse ocular magnification adjustment on macular thickness profile in different refractive errors in community-based adults
title_full The effect of transverse ocular magnification adjustment on macular thickness profile in different refractive errors in community-based adults
title_fullStr The effect of transverse ocular magnification adjustment on macular thickness profile in different refractive errors in community-based adults
title_full_unstemmed The effect of transverse ocular magnification adjustment on macular thickness profile in different refractive errors in community-based adults
title_short The effect of transverse ocular magnification adjustment on macular thickness profile in different refractive errors in community-based adults
title_sort effect of transverse ocular magnification adjustment on macular thickness profile in different refractive errors in community-based adults
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9007368/
https://www.ncbi.nlm.nih.gov/pubmed/35417477
http://dx.doi.org/10.1371/journal.pone.0266909
work_keys_str_mv AT niyazmandhamed theeffectoftransverseocularmagnificationadjustmentonmacularthicknessprofileindifferentrefractiveerrorsincommunitybasedadults
AT linghamgareth theeffectoftransverseocularmagnificationadjustmentonmacularthicknessprofileindifferentrefractiveerrorsincommunitybasedadults
AT sanfilippopaulg theeffectoftransverseocularmagnificationadjustmentonmacularthicknessprofileindifferentrefractiveerrorsincommunitybasedadults
AT blaszkowskamagdalena theeffectoftransverseocularmagnificationadjustmentonmacularthicknessprofileindifferentrefractiveerrorsincommunitybasedadults
AT franchinamaria theeffectoftransverseocularmagnificationadjustmentonmacularthicknessprofileindifferentrefractiveerrorsincommunitybasedadults
AT yazarseyhan theeffectoftransverseocularmagnificationadjustmentonmacularthicknessprofileindifferentrefractiveerrorsincommunitybasedadults
AT alonsocaneirodavid theeffectoftransverseocularmagnificationadjustmentonmacularthicknessprofileindifferentrefractiveerrorsincommunitybasedadults
AT mackeydavida theeffectoftransverseocularmagnificationadjustmentonmacularthicknessprofileindifferentrefractiveerrorsincommunitybasedadults
AT leesamanthaszeyee theeffectoftransverseocularmagnificationadjustmentonmacularthicknessprofileindifferentrefractiveerrorsincommunitybasedadults
AT niyazmandhamed effectoftransverseocularmagnificationadjustmentonmacularthicknessprofileindifferentrefractiveerrorsincommunitybasedadults
AT linghamgareth effectoftransverseocularmagnificationadjustmentonmacularthicknessprofileindifferentrefractiveerrorsincommunitybasedadults
AT sanfilippopaulg effectoftransverseocularmagnificationadjustmentonmacularthicknessprofileindifferentrefractiveerrorsincommunitybasedadults
AT blaszkowskamagdalena effectoftransverseocularmagnificationadjustmentonmacularthicknessprofileindifferentrefractiveerrorsincommunitybasedadults
AT franchinamaria effectoftransverseocularmagnificationadjustmentonmacularthicknessprofileindifferentrefractiveerrorsincommunitybasedadults
AT yazarseyhan effectoftransverseocularmagnificationadjustmentonmacularthicknessprofileindifferentrefractiveerrorsincommunitybasedadults
AT alonsocaneirodavid effectoftransverseocularmagnificationadjustmentonmacularthicknessprofileindifferentrefractiveerrorsincommunitybasedadults
AT mackeydavida effectoftransverseocularmagnificationadjustmentonmacularthicknessprofileindifferentrefractiveerrorsincommunitybasedadults
AT leesamanthaszeyee effectoftransverseocularmagnificationadjustmentonmacularthicknessprofileindifferentrefractiveerrorsincommunitybasedadults