Two case reports of transcatheter valve-in-valve implantation of Sapien 3 and MyVal in degenerated biological tricuspid prosthesis valves
BACKGROUND: Patients with severe tricuspid valve stenosis or dysfunction following degeneration of biological valve prosthesis in tricuspid position are complex, have substantial comorbidity, and very high surgical risk. CASE SUMMARY: We report two cases with transcatheter tricuspid valve-in-valve i...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9007432/ https://www.ncbi.nlm.nih.gov/pubmed/35434509 http://dx.doi.org/10.1093/ehjcr/ytac131 |
Sumario: | BACKGROUND: Patients with severe tricuspid valve stenosis or dysfunction following degeneration of biological valve prosthesis in tricuspid position are complex, have substantial comorbidity, and very high surgical risk. CASE SUMMARY: We report two cases with transcatheter tricuspid valve-in-valve implantation in patients with degenerated tricuspid bioprosthesis with transfemoral and transjugular access with Sapien 3 valve and MyVal, respectively. DISCUSSION: In patients with high surgical risk, transcatheter tricuspid valve implantation is a good alternative. Careful consideration of optimal access site, device size, and delivery system is paramount. This case report demonstrates technically feasible and safe transcatheter valve-in-valve implantantion in tricuspid position and highlights the importance of meticulous procedure planning. |
---|