BACKGROUND: Patients with severe tricuspid valve stenosis or dysfunction following degeneration of biological valve prosthesis in tricuspid position are complex, have substantial comorbidity, and very high surgical risk. CASE SUMMARY: We report two cases with transcatheter tricuspid valve-in-valve i...

Descripción completa

Detalles Bibliográficos
Autores principales: Jensen, Rebekka Vibjerg, Jensen, Jesper Khedri, Christiansen, Evald Høj, Tang, Mariann, Nielsen, Jens Cosedis, Terkelsen, Christian Juhl
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9007432/
https://www.ncbi.nlm.nih.gov/pubmed/35434509
http://dx.doi.org/10.1093/ehjcr/ytac131
_version_ 1784686847695257600
author Jensen, Rebekka Vibjerg
Jensen, Jesper Khedri
Christiansen, Evald Høj
Tang, Mariann
Nielsen, Jens Cosedis
Terkelsen, Christian Juhl
author_facet Jensen, Rebekka Vibjerg
Jensen, Jesper Khedri
Christiansen, Evald Høj
Tang, Mariann
Nielsen, Jens Cosedis
Terkelsen, Christian Juhl
author_sort Jensen, Rebekka Vibjerg
collection PubMed
description BACKGROUND: Patients with severe tricuspid valve stenosis or dysfunction following degeneration of biological valve prosthesis in tricuspid position are complex, have substantial comorbidity, and very high surgical risk. CASE SUMMARY: We report two cases with transcatheter tricuspid valve-in-valve implantation in patients with degenerated tricuspid bioprosthesis with transfemoral and transjugular access with Sapien 3 valve and MyVal, respectively. DISCUSSION: In patients with high surgical risk, transcatheter tricuspid valve implantation is a good alternative. Careful consideration of optimal access site, device size, and delivery system is paramount. This case report demonstrates technically feasible and safe transcatheter valve-in-valve implantantion in tricuspid position and highlights the importance of meticulous procedure planning.
format Online
Article
Text
id pubmed-9007432
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-90074322022-04-14 Two case reports of transcatheter valve-in-valve implantation of Sapien 3 and MyVal in degenerated biological tricuspid prosthesis valves Jensen, Rebekka Vibjerg Jensen, Jesper Khedri Christiansen, Evald Høj Tang, Mariann Nielsen, Jens Cosedis Terkelsen, Christian Juhl Eur Heart J Case Rep Case Series BACKGROUND: Patients with severe tricuspid valve stenosis or dysfunction following degeneration of biological valve prosthesis in tricuspid position are complex, have substantial comorbidity, and very high surgical risk. CASE SUMMARY: We report two cases with transcatheter tricuspid valve-in-valve implantation in patients with degenerated tricuspid bioprosthesis with transfemoral and transjugular access with Sapien 3 valve and MyVal, respectively. DISCUSSION: In patients with high surgical risk, transcatheter tricuspid valve implantation is a good alternative. Careful consideration of optimal access site, device size, and delivery system is paramount. This case report demonstrates technically feasible and safe transcatheter valve-in-valve implantantion in tricuspid position and highlights the importance of meticulous procedure planning. Oxford University Press 2022-03-23 /pmc/articles/PMC9007432/ /pubmed/35434509 http://dx.doi.org/10.1093/ehjcr/ytac131 Text en © The Author(s) 2022. Published by Oxford University Press on behalf of European Society of Cardiology. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Case Series
Jensen, Rebekka Vibjerg
Jensen, Jesper Khedri
Christiansen, Evald Høj
Tang, Mariann
Nielsen, Jens Cosedis
Terkelsen, Christian Juhl
Two case reports of transcatheter valve-in-valve implantation of Sapien 3 and MyVal in degenerated biological tricuspid prosthesis valves
title Two case reports of transcatheter valve-in-valve implantation of Sapien 3 and MyVal in degenerated biological tricuspid prosthesis valves
title_full Two case reports of transcatheter valve-in-valve implantation of Sapien 3 and MyVal in degenerated biological tricuspid prosthesis valves
title_fullStr Two case reports of transcatheter valve-in-valve implantation of Sapien 3 and MyVal in degenerated biological tricuspid prosthesis valves
title_full_unstemmed Two case reports of transcatheter valve-in-valve implantation of Sapien 3 and MyVal in degenerated biological tricuspid prosthesis valves
title_short Two case reports of transcatheter valve-in-valve implantation of Sapien 3 and MyVal in degenerated biological tricuspid prosthesis valves
title_sort two case reports of transcatheter valve-in-valve implantation of sapien 3 and myval in degenerated biological tricuspid prosthesis valves
topic Case Series
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9007432/
https://www.ncbi.nlm.nih.gov/pubmed/35434509
http://dx.doi.org/10.1093/ehjcr/ytac131
work_keys_str_mv AT jensenrebekkavibjerg twocasereportsoftranscathetervalveinvalveimplantationofsapien3andmyvalindegeneratedbiologicaltricuspidprosthesisvalves
AT jensenjesperkhedri twocasereportsoftranscathetervalveinvalveimplantationofsapien3andmyvalindegeneratedbiologicaltricuspidprosthesisvalves
AT christiansenevaldhøj twocasereportsoftranscathetervalveinvalveimplantationofsapien3andmyvalindegeneratedbiologicaltricuspidprosthesisvalves
AT tangmariann twocasereportsoftranscathetervalveinvalveimplantationofsapien3andmyvalindegeneratedbiologicaltricuspidprosthesisvalves
AT nielsenjenscosedis twocasereportsoftranscathetervalveinvalveimplantationofsapien3andmyvalindegeneratedbiologicaltricuspidprosthesisvalves
AT terkelsenchristianjuhl twocasereportsoftranscathetervalveinvalveimplantationofsapien3andmyvalindegeneratedbiologicaltricuspidprosthesisvalves