Cargando…

Comparison of peripheral refraction and higher-order aberrations between orthokeratology and multifocal soft contact lens designed with highly addition

PURPOSE: To compare peripheral defocus, higher-order aberrations (HOAs), and contrast visual acuity (CVA) in myopic children wearing orthokeratology (OK) lenses and multifocal soft contact lenses (MSCLs) designed with highly addition. METHODS: This is a prospective, nonrandomized, controlled study....

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Yingying, Li, Xue, Ding, Chenglu, Chen, Yunyun, Mao, Xinjie, Chen, Hao, Bao, Jinhua
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9007788/
https://www.ncbi.nlm.nih.gov/pubmed/35192031
http://dx.doi.org/10.1007/s00417-022-05573-1
_version_ 1784686927255961600
author Huang, Yingying
Li, Xue
Ding, Chenglu
Chen, Yunyun
Mao, Xinjie
Chen, Hao
Bao, Jinhua
author_facet Huang, Yingying
Li, Xue
Ding, Chenglu
Chen, Yunyun
Mao, Xinjie
Chen, Hao
Bao, Jinhua
author_sort Huang, Yingying
collection PubMed
description PURPOSE: To compare peripheral defocus, higher-order aberrations (HOAs), and contrast visual acuity (CVA) in myopic children wearing orthokeratology (OK) lenses and multifocal soft contact lenses (MSCLs) designed with highly addition. METHODS: This is a prospective, nonrandomized, controlled study. Subjects at 8 to 13 years of age with spherical equivalent refraction from − 1.00 to − 5.00 dioptres (D) were included in the OK group (n = 30) and MSCL group (n = 23). Relative peripheral corneal defocus (RPCD) and relative peripheral refraction (RPR) were measured before and after wearing lenses. HOAs including spherical aberration (SA), coma, trefoil, and total HOAs, and high (100%) and low (10%) CVA were compared between the groups. Axial length (AL) was measured before and after wearing the lenses for 1 year. RESULTS: After wearing the lenses, subjects in the MSCL group had RPCD and RPR values similar to the OK group at the paracentral (within 2 mm of the cornea or 20° of the retina, all p > 0.05) but larger than the OK group at the periphery (all p < 0.05). All HOAs increased after wearing the lenses except the trefoil in the MSCL group (all p < 0.05). HOAs increased more in the OK group (all p < 0.05). The 100% and 10% CVAs were worse in the MSCL group (p = 0.02 and p = 0.004). After 1 year, AL elongation was 0.37 mm (SD = 0.16) in the MSCL group and 0.28 mm (0.16) in the OK group (p = 0.06). CONCLUSION: MSCL produced larger myopic defocus at the periphery, increased less HOAs and had worse CVA than OK lens. The high addition of this MSCL did not result in better myopia control efficacy TRIAL REGISTRATION: Chinese Clinical Trial Registry: ChiCTR1800018564. Registered 25 September 2018; retrospectively registered, http://www.chictr.org.cn/showproj.aspx?proj=31376
format Online
Article
Text
id pubmed-9007788
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-90077882022-04-19 Comparison of peripheral refraction and higher-order aberrations between orthokeratology and multifocal soft contact lens designed with highly addition Huang, Yingying Li, Xue Ding, Chenglu Chen, Yunyun Mao, Xinjie Chen, Hao Bao, Jinhua Graefes Arch Clin Exp Ophthalmol Pediatrics PURPOSE: To compare peripheral defocus, higher-order aberrations (HOAs), and contrast visual acuity (CVA) in myopic children wearing orthokeratology (OK) lenses and multifocal soft contact lenses (MSCLs) designed with highly addition. METHODS: This is a prospective, nonrandomized, controlled study. Subjects at 8 to 13 years of age with spherical equivalent refraction from − 1.00 to − 5.00 dioptres (D) were included in the OK group (n = 30) and MSCL group (n = 23). Relative peripheral corneal defocus (RPCD) and relative peripheral refraction (RPR) were measured before and after wearing lenses. HOAs including spherical aberration (SA), coma, trefoil, and total HOAs, and high (100%) and low (10%) CVA were compared between the groups. Axial length (AL) was measured before and after wearing the lenses for 1 year. RESULTS: After wearing the lenses, subjects in the MSCL group had RPCD and RPR values similar to the OK group at the paracentral (within 2 mm of the cornea or 20° of the retina, all p > 0.05) but larger than the OK group at the periphery (all p < 0.05). All HOAs increased after wearing the lenses except the trefoil in the MSCL group (all p < 0.05). HOAs increased more in the OK group (all p < 0.05). The 100% and 10% CVAs were worse in the MSCL group (p = 0.02 and p = 0.004). After 1 year, AL elongation was 0.37 mm (SD = 0.16) in the MSCL group and 0.28 mm (0.16) in the OK group (p = 0.06). CONCLUSION: MSCL produced larger myopic defocus at the periphery, increased less HOAs and had worse CVA than OK lens. The high addition of this MSCL did not result in better myopia control efficacy TRIAL REGISTRATION: Chinese Clinical Trial Registry: ChiCTR1800018564. Registered 25 September 2018; retrospectively registered, http://www.chictr.org.cn/showproj.aspx?proj=31376 Springer Berlin Heidelberg 2022-02-22 2022 /pmc/articles/PMC9007788/ /pubmed/35192031 http://dx.doi.org/10.1007/s00417-022-05573-1 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Pediatrics
Huang, Yingying
Li, Xue
Ding, Chenglu
Chen, Yunyun
Mao, Xinjie
Chen, Hao
Bao, Jinhua
Comparison of peripheral refraction and higher-order aberrations between orthokeratology and multifocal soft contact lens designed with highly addition
title Comparison of peripheral refraction and higher-order aberrations between orthokeratology and multifocal soft contact lens designed with highly addition
title_full Comparison of peripheral refraction and higher-order aberrations between orthokeratology and multifocal soft contact lens designed with highly addition
title_fullStr Comparison of peripheral refraction and higher-order aberrations between orthokeratology and multifocal soft contact lens designed with highly addition
title_full_unstemmed Comparison of peripheral refraction and higher-order aberrations between orthokeratology and multifocal soft contact lens designed with highly addition
title_short Comparison of peripheral refraction and higher-order aberrations between orthokeratology and multifocal soft contact lens designed with highly addition
title_sort comparison of peripheral refraction and higher-order aberrations between orthokeratology and multifocal soft contact lens designed with highly addition
topic Pediatrics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9007788/
https://www.ncbi.nlm.nih.gov/pubmed/35192031
http://dx.doi.org/10.1007/s00417-022-05573-1
work_keys_str_mv AT huangyingying comparisonofperipheralrefractionandhigherorderaberrationsbetweenorthokeratologyandmultifocalsoftcontactlensdesignedwithhighlyaddition
AT lixue comparisonofperipheralrefractionandhigherorderaberrationsbetweenorthokeratologyandmultifocalsoftcontactlensdesignedwithhighlyaddition
AT dingchenglu comparisonofperipheralrefractionandhigherorderaberrationsbetweenorthokeratologyandmultifocalsoftcontactlensdesignedwithhighlyaddition
AT chenyunyun comparisonofperipheralrefractionandhigherorderaberrationsbetweenorthokeratologyandmultifocalsoftcontactlensdesignedwithhighlyaddition
AT maoxinjie comparisonofperipheralrefractionandhigherorderaberrationsbetweenorthokeratologyandmultifocalsoftcontactlensdesignedwithhighlyaddition
AT chenhao comparisonofperipheralrefractionandhigherorderaberrationsbetweenorthokeratologyandmultifocalsoftcontactlensdesignedwithhighlyaddition
AT baojinhua comparisonofperipheralrefractionandhigherorderaberrationsbetweenorthokeratologyandmultifocalsoftcontactlensdesignedwithhighlyaddition