Comprehensive Evaluation of Carbon-Fiber-Reinforced Polyetheretherketone (CFR-PEEK) Spinal Hardware for Proton and Photon Planning
Purpose: To evaluate a novel spine implant, carbon-fiber-reinforced polyetheretherketone (CFR-PEEK), for proton and photon treatment planning. Materials and Methods: We compared target coverage and sparing of organs-at-risk (OARs) for a spinal phantom with 4 different spine configurations: (a) norma...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9009152/ https://www.ncbi.nlm.nih.gov/pubmed/35410544 http://dx.doi.org/10.1177/15330338221091700 |
_version_ | 1784687215100559360 |
---|---|
author | Shi, Chengyu Lin, Haibo Huang, Sheng Xiong, Weijun Hu, Lei Choi, Isabelle Press, Robert Hasan, Shaakir Simone, Charles Chhabra, Arpit |
author_facet | Shi, Chengyu Lin, Haibo Huang, Sheng Xiong, Weijun Hu, Lei Choi, Isabelle Press, Robert Hasan, Shaakir Simone, Charles Chhabra, Arpit |
author_sort | Shi, Chengyu |
collection | PubMed |
description | Purpose: To evaluate a novel spine implant, carbon-fiber-reinforced polyetheretherketone (CFR-PEEK), for proton and photon treatment planning. Materials and Methods: We compared target coverage and sparing of organs-at-risk (OARs) for a spinal phantom with 4 different spine configurations: (a) normal (no implant); (b) Titanium; (c) CFR-PEEK; and (d) hybrid (CFR-PEEK with Titanium tulip head). The spinal phantom was imaged via computed tomography (CT) scan, and the iterative Metal Artifact Reduction (iMAR) CT set was used for planning. A representative spinal chordoma target and associated OARs were contoured. The prescription dose was 50 Gy to the initial target volume, followed by a 24 Gy boost, for which multi-field optimization (MFO) proton plans were developed with a 3 mm setup and 3.5% range uncertainties. For photon planning, volumetric modulated arc therapy (VMAT) plans were developed for the initial and boost plans. OAR dose constraints were set according to our institutional guidelines. Results: For the 4 spine configurations, the proton plans achieved similar nominal target coverage and OARs sparing. While evaluating coverage and OAR dose under uncertainty scenario analysis for initial clinical target volume (CTV) 50 Gy 95% and 90% coverage, higher means and the narrower band of doses variations were achieved for the normal and CFR-PEEK plans. Similarly, uncertainty analysis of spinal cord D(max) showed tighter distribution for normal and CFR-PEEK plans. Overall plan quality showed no significant difference for photon planning when compared to normal spine versus other inserts. However, for proton planning, there is a larger difference for the normal spine insert scenario versus the Titanium insert scenario. For each insert scenario comparison between photon and proton plans, there was a larger difference for OARs: heart and spinal cord. Conclusion: The CFR-PEEK implant has similar clinical properties to a normal spine for proton planning, allowing us to pass protons through the material and achieve superior target coverage and OAR sparing under nominal and uncertainty conditions. |
format | Online Article Text |
id | pubmed-9009152 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-90091522022-04-15 Comprehensive Evaluation of Carbon-Fiber-Reinforced Polyetheretherketone (CFR-PEEK) Spinal Hardware for Proton and Photon Planning Shi, Chengyu Lin, Haibo Huang, Sheng Xiong, Weijun Hu, Lei Choi, Isabelle Press, Robert Hasan, Shaakir Simone, Charles Chhabra, Arpit Technol Cancer Res Treat Original Article Purpose: To evaluate a novel spine implant, carbon-fiber-reinforced polyetheretherketone (CFR-PEEK), for proton and photon treatment planning. Materials and Methods: We compared target coverage and sparing of organs-at-risk (OARs) for a spinal phantom with 4 different spine configurations: (a) normal (no implant); (b) Titanium; (c) CFR-PEEK; and (d) hybrid (CFR-PEEK with Titanium tulip head). The spinal phantom was imaged via computed tomography (CT) scan, and the iterative Metal Artifact Reduction (iMAR) CT set was used for planning. A representative spinal chordoma target and associated OARs were contoured. The prescription dose was 50 Gy to the initial target volume, followed by a 24 Gy boost, for which multi-field optimization (MFO) proton plans were developed with a 3 mm setup and 3.5% range uncertainties. For photon planning, volumetric modulated arc therapy (VMAT) plans were developed for the initial and boost plans. OAR dose constraints were set according to our institutional guidelines. Results: For the 4 spine configurations, the proton plans achieved similar nominal target coverage and OARs sparing. While evaluating coverage and OAR dose under uncertainty scenario analysis for initial clinical target volume (CTV) 50 Gy 95% and 90% coverage, higher means and the narrower band of doses variations were achieved for the normal and CFR-PEEK plans. Similarly, uncertainty analysis of spinal cord D(max) showed tighter distribution for normal and CFR-PEEK plans. Overall plan quality showed no significant difference for photon planning when compared to normal spine versus other inserts. However, for proton planning, there is a larger difference for the normal spine insert scenario versus the Titanium insert scenario. For each insert scenario comparison between photon and proton plans, there was a larger difference for OARs: heart and spinal cord. Conclusion: The CFR-PEEK implant has similar clinical properties to a normal spine for proton planning, allowing us to pass protons through the material and achieve superior target coverage and OAR sparing under nominal and uncertainty conditions. SAGE Publications 2022-04-12 /pmc/articles/PMC9009152/ /pubmed/35410544 http://dx.doi.org/10.1177/15330338221091700 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Article Shi, Chengyu Lin, Haibo Huang, Sheng Xiong, Weijun Hu, Lei Choi, Isabelle Press, Robert Hasan, Shaakir Simone, Charles Chhabra, Arpit Comprehensive Evaluation of Carbon-Fiber-Reinforced Polyetheretherketone (CFR-PEEK) Spinal Hardware for Proton and Photon Planning |
title | Comprehensive Evaluation of Carbon-Fiber-Reinforced
Polyetheretherketone (CFR-PEEK) Spinal Hardware for Proton and Photon
Planning |
title_full | Comprehensive Evaluation of Carbon-Fiber-Reinforced
Polyetheretherketone (CFR-PEEK) Spinal Hardware for Proton and Photon
Planning |
title_fullStr | Comprehensive Evaluation of Carbon-Fiber-Reinforced
Polyetheretherketone (CFR-PEEK) Spinal Hardware for Proton and Photon
Planning |
title_full_unstemmed | Comprehensive Evaluation of Carbon-Fiber-Reinforced
Polyetheretherketone (CFR-PEEK) Spinal Hardware for Proton and Photon
Planning |
title_short | Comprehensive Evaluation of Carbon-Fiber-Reinforced
Polyetheretherketone (CFR-PEEK) Spinal Hardware for Proton and Photon
Planning |
title_sort | comprehensive evaluation of carbon-fiber-reinforced
polyetheretherketone (cfr-peek) spinal hardware for proton and photon
planning |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9009152/ https://www.ncbi.nlm.nih.gov/pubmed/35410544 http://dx.doi.org/10.1177/15330338221091700 |
work_keys_str_mv | AT shichengyu comprehensiveevaluationofcarbonfiberreinforcedpolyetheretherketonecfrpeekspinalhardwareforprotonandphotonplanning AT linhaibo comprehensiveevaluationofcarbonfiberreinforcedpolyetheretherketonecfrpeekspinalhardwareforprotonandphotonplanning AT huangsheng comprehensiveevaluationofcarbonfiberreinforcedpolyetheretherketonecfrpeekspinalhardwareforprotonandphotonplanning AT xiongweijun comprehensiveevaluationofcarbonfiberreinforcedpolyetheretherketonecfrpeekspinalhardwareforprotonandphotonplanning AT hulei comprehensiveevaluationofcarbonfiberreinforcedpolyetheretherketonecfrpeekspinalhardwareforprotonandphotonplanning AT choiisabelle comprehensiveevaluationofcarbonfiberreinforcedpolyetheretherketonecfrpeekspinalhardwareforprotonandphotonplanning AT pressrobert comprehensiveevaluationofcarbonfiberreinforcedpolyetheretherketonecfrpeekspinalhardwareforprotonandphotonplanning AT hasanshaakir comprehensiveevaluationofcarbonfiberreinforcedpolyetheretherketonecfrpeekspinalhardwareforprotonandphotonplanning AT simonecharles comprehensiveevaluationofcarbonfiberreinforcedpolyetheretherketonecfrpeekspinalhardwareforprotonandphotonplanning AT chhabraarpit comprehensiveevaluationofcarbonfiberreinforcedpolyetheretherketonecfrpeekspinalhardwareforprotonandphotonplanning |