Cargando…

Filling Bone Defects after Hip Arthroplasty Revision Using Hydroxyapatite/β-tricalcium Phosphate: A Case Report with Long-term Result

INTRODUCTION: The increasing number of primary total hip replacements means that there is an increased need for hip arthroplasty revisions. The periprosthetic fractures which cause bone defects can occur during removal of the femoral component and healing of these fractures can be delayed. In femora...

Descripción completa

Detalles Bibliográficos
Autores principales: Petronis, Sandris, Jakusonoka, Ruta, Linovs, Viktors, Jumtins, Andris
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Indian Orthopaedic Research Group 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9009477/
https://www.ncbi.nlm.nih.gov/pubmed/35437485
http://dx.doi.org/10.13107/jocr.2021.v11.i06.2234
_version_ 1784687276810305536
author Petronis, Sandris
Jakusonoka, Ruta
Linovs, Viktors
Jumtins, Andris
author_facet Petronis, Sandris
Jakusonoka, Ruta
Linovs, Viktors
Jumtins, Andris
author_sort Petronis, Sandris
collection PubMed
description INTRODUCTION: The increasing number of primary total hip replacements means that there is an increased need for hip arthroplasty revisions. The periprosthetic fractures which cause bone defects can occur during removal of the femoral component and healing of these fractures can be delayed. In femoral bone defects during revisions, there are no metal augments for filling these defects. CASE REPORT: Fifty-nine-year-old female presented with infected loosening of the left hip non-cemented endoprosthesis 5 years after surgery. The patient underwent removal of endoprosthesis. In 2 months, re-implantation of non-cemented endoprosthesis was performed and biphasic calcium phosphate (BCP) ceramic granules with hydroxyapatite/β-tricalcium phosphate (HAp/β-TCP) were implanted in the femoral bone defects. Eleven months following the arthroplasty patient had periprosthetic fracture of the distal third of the left femur. The osteosynthesis was performed and BCP ceramic granules with HAp/β-TCP were used to fill the bone defect. Long-term follow-up showed very good functional outcome and bone defect healing. CONCLUSION: The BCP ceramic granules with HAp/β-TCP material adjusted to the bone defect anatomy, showed effective femoral bone defect and periprosthetic fracture healing in a patient with hip arthroplasty revision and periprosthetic fracture.
format Online
Article
Text
id pubmed-9009477
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Indian Orthopaedic Research Group
record_format MEDLINE/PubMed
spelling pubmed-90094772022-04-17 Filling Bone Defects after Hip Arthroplasty Revision Using Hydroxyapatite/β-tricalcium Phosphate: A Case Report with Long-term Result Petronis, Sandris Jakusonoka, Ruta Linovs, Viktors Jumtins, Andris J Orthop Case Rep Case Report INTRODUCTION: The increasing number of primary total hip replacements means that there is an increased need for hip arthroplasty revisions. The periprosthetic fractures which cause bone defects can occur during removal of the femoral component and healing of these fractures can be delayed. In femoral bone defects during revisions, there are no metal augments for filling these defects. CASE REPORT: Fifty-nine-year-old female presented with infected loosening of the left hip non-cemented endoprosthesis 5 years after surgery. The patient underwent removal of endoprosthesis. In 2 months, re-implantation of non-cemented endoprosthesis was performed and biphasic calcium phosphate (BCP) ceramic granules with hydroxyapatite/β-tricalcium phosphate (HAp/β-TCP) were implanted in the femoral bone defects. Eleven months following the arthroplasty patient had periprosthetic fracture of the distal third of the left femur. The osteosynthesis was performed and BCP ceramic granules with HAp/β-TCP were used to fill the bone defect. Long-term follow-up showed very good functional outcome and bone defect healing. CONCLUSION: The BCP ceramic granules with HAp/β-TCP material adjusted to the bone defect anatomy, showed effective femoral bone defect and periprosthetic fracture healing in a patient with hip arthroplasty revision and periprosthetic fracture. Indian Orthopaedic Research Group 2021-06 /pmc/articles/PMC9009477/ /pubmed/35437485 http://dx.doi.org/10.13107/jocr.2021.v11.i06.2234 Text en Copyright: © Indian Orthopaedic Research Group https://creativecommons.org/licenses/by-nc-sa/3.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Petronis, Sandris
Jakusonoka, Ruta
Linovs, Viktors
Jumtins, Andris
Filling Bone Defects after Hip Arthroplasty Revision Using Hydroxyapatite/β-tricalcium Phosphate: A Case Report with Long-term Result
title Filling Bone Defects after Hip Arthroplasty Revision Using Hydroxyapatite/β-tricalcium Phosphate: A Case Report with Long-term Result
title_full Filling Bone Defects after Hip Arthroplasty Revision Using Hydroxyapatite/β-tricalcium Phosphate: A Case Report with Long-term Result
title_fullStr Filling Bone Defects after Hip Arthroplasty Revision Using Hydroxyapatite/β-tricalcium Phosphate: A Case Report with Long-term Result
title_full_unstemmed Filling Bone Defects after Hip Arthroplasty Revision Using Hydroxyapatite/β-tricalcium Phosphate: A Case Report with Long-term Result
title_short Filling Bone Defects after Hip Arthroplasty Revision Using Hydroxyapatite/β-tricalcium Phosphate: A Case Report with Long-term Result
title_sort filling bone defects after hip arthroplasty revision using hydroxyapatite/β-tricalcium phosphate: a case report with long-term result
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9009477/
https://www.ncbi.nlm.nih.gov/pubmed/35437485
http://dx.doi.org/10.13107/jocr.2021.v11.i06.2234
work_keys_str_mv AT petronissandris fillingbonedefectsafterhiparthroplastyrevisionusinghydroxyapatitebtricalciumphosphateacasereportwithlongtermresult
AT jakusonokaruta fillingbonedefectsafterhiparthroplastyrevisionusinghydroxyapatitebtricalciumphosphateacasereportwithlongtermresult
AT linovsviktors fillingbonedefectsafterhiparthroplastyrevisionusinghydroxyapatitebtricalciumphosphateacasereportwithlongtermresult
AT jumtinsandris fillingbonedefectsafterhiparthroplastyrevisionusinghydroxyapatitebtricalciumphosphateacasereportwithlongtermresult