Cargando…

Indirect estimation of reference intervals for thyroid parameters using advia centaur XP analyzer

BACKGROUND: The aim of this study was to determine the reference intervals (RIs) for thyroid stimulating hormone (TSH), free thyroxine (FT4), free triiodothyronine (FT3) and FT3/FT4 ratio using indirect methods. METHODS: We analyzed 1256 results TSH, FT4 and FT3 collected from a laboratory informati...

Descripción completa

Detalles Bibliográficos
Autores principales: Mirjanić-Azarić, Bosa, Milinković, Neda, Bogavac-Stanojević, Natasa, Avram, Sanja, Stojaković-Jelisavac, Tanja, Stojanović, Darja
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Society of Medical Biochemists of Serbia, Belgrade 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9010039/
https://www.ncbi.nlm.nih.gov/pubmed/35510197
http://dx.doi.org/10.5937/jomb0-33543
_version_ 1784687397354602496
author Mirjanić-Azarić, Bosa
Milinković, Neda
Bogavac-Stanojević, Natasa
Avram, Sanja
Stojaković-Jelisavac, Tanja
Stojanović, Darja
author_facet Mirjanić-Azarić, Bosa
Milinković, Neda
Bogavac-Stanojević, Natasa
Avram, Sanja
Stojaković-Jelisavac, Tanja
Stojanović, Darja
author_sort Mirjanić-Azarić, Bosa
collection PubMed
description BACKGROUND: The aim of this study was to determine the reference intervals (RIs) for thyroid stimulating hormone (TSH), free thyroxine (FT4), free triiodothyronine (FT3) and FT3/FT4 ratio using indirect methods. METHODS: We analyzed 1256 results TSH, FT4 and FT3 collected from a laboratory information system between 2017 and 2021. All measurements were performed on a Siemens ADVIA Centaur XP analyzer using the chemiluminescent immunoassay. We calculated the values of the 2.5th and 97.5th percentiles as recommended by the IFCC (CLSI C28-A3). RESULTS: The RIs derived for TSH, FT4, FT3 and FT3/FT4 ratio were 0.34-4.10 mIU/L, 11.3-20.6 pmol/L, 3.5-6.32 pmol/L and 0.21-0.47, respectively. We found a significant difference between calculated RIs for the TSH and FT4 and those recommended by the manufacturer. Also, FT3 values were significantly higher in the group younger than 30 years relative to the fourth decade (5.26 vs. 5.02, p=0.005), the fifth decade (5.26 vs. 4.94, p=0.001), the sixth decade (5.26 vs. 4.87, p<0.001), the seventh decade (5.26 vs. 4.79, p<0.001) and the group older than 70 years old (5.26 vs. 4.55, p<0.001). Likewise, we found for TSH values and FT3/FT4 ratio a significant difference (p <0.001) between different age groups. CONCLUSIONS: The establishing RIs for the population of the Republic of Srpska were significantly differed from the recommended RIs by the manufacturer for TSH and FT4. Our results encourage other laboratories to develop their own RIs for thyroid parameters by applying CLSI recommendations.
format Online
Article
Text
id pubmed-9010039
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Society of Medical Biochemists of Serbia, Belgrade
record_format MEDLINE/PubMed
spelling pubmed-90100392022-05-03 Indirect estimation of reference intervals for thyroid parameters using advia centaur XP analyzer Mirjanić-Azarić, Bosa Milinković, Neda Bogavac-Stanojević, Natasa Avram, Sanja Stojaković-Jelisavac, Tanja Stojanović, Darja J Med Biochem Original Paper BACKGROUND: The aim of this study was to determine the reference intervals (RIs) for thyroid stimulating hormone (TSH), free thyroxine (FT4), free triiodothyronine (FT3) and FT3/FT4 ratio using indirect methods. METHODS: We analyzed 1256 results TSH, FT4 and FT3 collected from a laboratory information system between 2017 and 2021. All measurements were performed on a Siemens ADVIA Centaur XP analyzer using the chemiluminescent immunoassay. We calculated the values of the 2.5th and 97.5th percentiles as recommended by the IFCC (CLSI C28-A3). RESULTS: The RIs derived for TSH, FT4, FT3 and FT3/FT4 ratio were 0.34-4.10 mIU/L, 11.3-20.6 pmol/L, 3.5-6.32 pmol/L and 0.21-0.47, respectively. We found a significant difference between calculated RIs for the TSH and FT4 and those recommended by the manufacturer. Also, FT3 values were significantly higher in the group younger than 30 years relative to the fourth decade (5.26 vs. 5.02, p=0.005), the fifth decade (5.26 vs. 4.94, p=0.001), the sixth decade (5.26 vs. 4.87, p<0.001), the seventh decade (5.26 vs. 4.79, p<0.001) and the group older than 70 years old (5.26 vs. 4.55, p<0.001). Likewise, we found for TSH values and FT3/FT4 ratio a significant difference (p <0.001) between different age groups. CONCLUSIONS: The establishing RIs for the population of the Republic of Srpska were significantly differed from the recommended RIs by the manufacturer for TSH and FT4. Our results encourage other laboratories to develop their own RIs for thyroid parameters by applying CLSI recommendations. Society of Medical Biochemists of Serbia, Belgrade 2022-04-08 2022-04-08 /pmc/articles/PMC9010039/ /pubmed/35510197 http://dx.doi.org/10.5937/jomb0-33543 Text en 2022 Bosa Mirjanić-Azarić, Neda Milinković, Natasa Bogavac-Stanojević, Sanja Avram, Tanja Stojaković-Jelisavac, Darja Stojanović, published by CEON/CEES https://creativecommons.org/licenses/by/4.0/This work is licensed under the Creative Commons Attribution 4.0 License.
spellingShingle Original Paper
Mirjanić-Azarić, Bosa
Milinković, Neda
Bogavac-Stanojević, Natasa
Avram, Sanja
Stojaković-Jelisavac, Tanja
Stojanović, Darja
Indirect estimation of reference intervals for thyroid parameters using advia centaur XP analyzer
title Indirect estimation of reference intervals for thyroid parameters using advia centaur XP analyzer
title_full Indirect estimation of reference intervals for thyroid parameters using advia centaur XP analyzer
title_fullStr Indirect estimation of reference intervals for thyroid parameters using advia centaur XP analyzer
title_full_unstemmed Indirect estimation of reference intervals for thyroid parameters using advia centaur XP analyzer
title_short Indirect estimation of reference intervals for thyroid parameters using advia centaur XP analyzer
title_sort indirect estimation of reference intervals for thyroid parameters using advia centaur xp analyzer
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9010039/
https://www.ncbi.nlm.nih.gov/pubmed/35510197
http://dx.doi.org/10.5937/jomb0-33543
work_keys_str_mv AT mirjanicazaricbosa indirectestimationofreferenceintervalsforthyroidparametersusingadviacentaurxpanalyzer
AT milinkovicneda indirectestimationofreferenceintervalsforthyroidparametersusingadviacentaurxpanalyzer
AT bogavacstanojevicnatasa indirectestimationofreferenceintervalsforthyroidparametersusingadviacentaurxpanalyzer
AT avramsanja indirectestimationofreferenceintervalsforthyroidparametersusingadviacentaurxpanalyzer
AT stojakovicjelisavactanja indirectestimationofreferenceintervalsforthyroidparametersusingadviacentaurxpanalyzer
AT stojanovicdarja indirectestimationofreferenceintervalsforthyroidparametersusingadviacentaurxpanalyzer