Cargando…

Inter-Observer and Intra-Observer Variability in Gross Tumor Volume Delineation of Primary Esophageal Carcinomas Based on Different Combinations of Diagnostic Multimodal Images

BACKGROUND AND PURPOSE: This study aimed to investigate inter-/intra-observer delineation variability in GTVs of primary esophageal carcinomas (ECs) based on planning CT with reference to different combinations of diagnostic multimodal images from endoscopy/EUS, esophagography and FDG-PET/CT. MATERI...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Fengxiang, Li, Yankang, Wang, Xue, Zhang, Yingjie, Liu, Xijun, Liu, Shanshan, Wang, Wei, Wang, Jinzhi, Guo, Yanluan, Xu, Min, Li, Jianbin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9010659/
https://www.ncbi.nlm.nih.gov/pubmed/35433413
http://dx.doi.org/10.3389/fonc.2022.817413
Descripción
Sumario:BACKGROUND AND PURPOSE: This study aimed to investigate inter-/intra-observer delineation variability in GTVs of primary esophageal carcinomas (ECs) based on planning CT with reference to different combinations of diagnostic multimodal images from endoscopy/EUS, esophagography and FDG-PET/CT. MATERIALS AND METHODS: Fifty patients with pathologically proven thoracic EC who underwent diagnostic multimodal images before concurrent chemoradiotherapy were enrolled. Five radiation oncologist independently delineated the GTVs based on planning CT only (GTV(C)), CT combined with endoscopy/EUS (GTV(CE)), CT combined with endoscopy/EUS and esophagography (X-ray) (GTV(CEX)), and CT combined with endoscopy/EUS, esophagography, and FDG-PET/CT (GTV(CEXP)). The intra-/inter-observer variability in the volume, longitudinal length, generalized CI (CI(gen)), and position of the GTVs were assessed. RESULTS: The intra-/inter-observer variability in the volume and longitudinal length of the GTVs showed no significant differences (p>0.05). The mean intra-observer CI(gen) values for all observers was 0.73 ± 0.15. The mean inter-observer CI(gen) values for the four multimodal image combinations was 0.67 ± 0.11. The inter-observer CI(gen) for the four combined images was the largest, showing significant differences with those for the other three combinations. The intra-observer CI(gen) among different observers and inter-observer CI(gen) among different combinations of multimodal images showed significant differences (p<0.001). The intra-observer CI(gen) for the senior radiotherapists was larger than that for the junior radiotherapists (p<0.001). CONCLUSION: For radiation oncologists with advanced medical imaging training and clinical experience, using diagnostic multimodal images from endoscopy/EUS, esophagography, and FDG-PET/CT could reduce the intra-/inter-observer variability and increase the accuracy of target delineation in primary esophageal carcinomas.