Cargando…

Visualizing tumor angiogenesis and boundary with polygon-scanning multiscale photoacoustic microscopy

Recently, we developed an integrated optical-resolution (OR) and acoustic-resolution (AR) PAM, which has multiscale imaging capability using different resolutions. However, limited by the scanning method, a tradeoff exists between the imaging speed and field of view, which impedes its wider applicat...

Descripción completa

Detalles Bibliográficos
Autores principales: Xu, Zhiqiang, Pan, Yinhao, Chen, Ningbo, Zeng, Silue, Liu, Liangjian, Gao, Rongkang, Zhang, Jianhui, Fang, Chihua, Song, Liang, Liu, Chengbo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9010793/
https://www.ncbi.nlm.nih.gov/pubmed/35433255
http://dx.doi.org/10.1016/j.pacs.2022.100342
_version_ 1784687560563359744
author Xu, Zhiqiang
Pan, Yinhao
Chen, Ningbo
Zeng, Silue
Liu, Liangjian
Gao, Rongkang
Zhang, Jianhui
Fang, Chihua
Song, Liang
Liu, Chengbo
author_facet Xu, Zhiqiang
Pan, Yinhao
Chen, Ningbo
Zeng, Silue
Liu, Liangjian
Gao, Rongkang
Zhang, Jianhui
Fang, Chihua
Song, Liang
Liu, Chengbo
author_sort Xu, Zhiqiang
collection PubMed
description Recently, we developed an integrated optical-resolution (OR) and acoustic-resolution (AR) PAM, which has multiscale imaging capability using different resolutions. However, limited by the scanning method, a tradeoff exists between the imaging speed and field of view, which impedes its wider applications. Here, we present an improved multiscale PAM which achieves high-speed wide-field imaging based on a homemade polygon scanner. Encoder trigger mode was proposed to avoid jittering of the polygon scanner during imaging. Distortions caused by polygon scanning were analyzed theoretically and compared with traditional types of distortions in optical-scanning PAM. Then a depth correction method was proposed and verified to compensate for the distortions. System characterization of OR-PAM and AR-PAM was performed prior to in vivo imaging. Blood reperfusion of an in vivo mouse ear was imaged continuously to demonstrate the feasibility of the multiscale PAM for high-speed imaging. Results showed that the maximum B-scan rate could be 14.65 Hz in a fixed range of 10 mm. Compared with our previous multiscale system, the imaging speed of the improved system was increased by a factor of 12.35. In vivo imaging of a subcutaneously inoculated B-16 melanoma of a mouse was performed. Results showed that the blood vasculature around the melanoma could be resolved and the melanoma could be visualized at a depth up to 1.6 mm using the multiscale PAM.
format Online
Article
Text
id pubmed-9010793
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-90107932022-04-16 Visualizing tumor angiogenesis and boundary with polygon-scanning multiscale photoacoustic microscopy Xu, Zhiqiang Pan, Yinhao Chen, Ningbo Zeng, Silue Liu, Liangjian Gao, Rongkang Zhang, Jianhui Fang, Chihua Song, Liang Liu, Chengbo Photoacoustics Research Article Recently, we developed an integrated optical-resolution (OR) and acoustic-resolution (AR) PAM, which has multiscale imaging capability using different resolutions. However, limited by the scanning method, a tradeoff exists between the imaging speed and field of view, which impedes its wider applications. Here, we present an improved multiscale PAM which achieves high-speed wide-field imaging based on a homemade polygon scanner. Encoder trigger mode was proposed to avoid jittering of the polygon scanner during imaging. Distortions caused by polygon scanning were analyzed theoretically and compared with traditional types of distortions in optical-scanning PAM. Then a depth correction method was proposed and verified to compensate for the distortions. System characterization of OR-PAM and AR-PAM was performed prior to in vivo imaging. Blood reperfusion of an in vivo mouse ear was imaged continuously to demonstrate the feasibility of the multiscale PAM for high-speed imaging. Results showed that the maximum B-scan rate could be 14.65 Hz in a fixed range of 10 mm. Compared with our previous multiscale system, the imaging speed of the improved system was increased by a factor of 12.35. In vivo imaging of a subcutaneously inoculated B-16 melanoma of a mouse was performed. Results showed that the blood vasculature around the melanoma could be resolved and the melanoma could be visualized at a depth up to 1.6 mm using the multiscale PAM. Elsevier 2022-02-23 /pmc/articles/PMC9010793/ /pubmed/35433255 http://dx.doi.org/10.1016/j.pacs.2022.100342 Text en © 2022 The Authors https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Research Article
Xu, Zhiqiang
Pan, Yinhao
Chen, Ningbo
Zeng, Silue
Liu, Liangjian
Gao, Rongkang
Zhang, Jianhui
Fang, Chihua
Song, Liang
Liu, Chengbo
Visualizing tumor angiogenesis and boundary with polygon-scanning multiscale photoacoustic microscopy
title Visualizing tumor angiogenesis and boundary with polygon-scanning multiscale photoacoustic microscopy
title_full Visualizing tumor angiogenesis and boundary with polygon-scanning multiscale photoacoustic microscopy
title_fullStr Visualizing tumor angiogenesis and boundary with polygon-scanning multiscale photoacoustic microscopy
title_full_unstemmed Visualizing tumor angiogenesis and boundary with polygon-scanning multiscale photoacoustic microscopy
title_short Visualizing tumor angiogenesis and boundary with polygon-scanning multiscale photoacoustic microscopy
title_sort visualizing tumor angiogenesis and boundary with polygon-scanning multiscale photoacoustic microscopy
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9010793/
https://www.ncbi.nlm.nih.gov/pubmed/35433255
http://dx.doi.org/10.1016/j.pacs.2022.100342
work_keys_str_mv AT xuzhiqiang visualizingtumorangiogenesisandboundarywithpolygonscanningmultiscalephotoacousticmicroscopy
AT panyinhao visualizingtumorangiogenesisandboundarywithpolygonscanningmultiscalephotoacousticmicroscopy
AT chenningbo visualizingtumorangiogenesisandboundarywithpolygonscanningmultiscalephotoacousticmicroscopy
AT zengsilue visualizingtumorangiogenesisandboundarywithpolygonscanningmultiscalephotoacousticmicroscopy
AT liuliangjian visualizingtumorangiogenesisandboundarywithpolygonscanningmultiscalephotoacousticmicroscopy
AT gaorongkang visualizingtumorangiogenesisandboundarywithpolygonscanningmultiscalephotoacousticmicroscopy
AT zhangjianhui visualizingtumorangiogenesisandboundarywithpolygonscanningmultiscalephotoacousticmicroscopy
AT fangchihua visualizingtumorangiogenesisandboundarywithpolygonscanningmultiscalephotoacousticmicroscopy
AT songliang visualizingtumorangiogenesisandboundarywithpolygonscanningmultiscalephotoacousticmicroscopy
AT liuchengbo visualizingtumorangiogenesisandboundarywithpolygonscanningmultiscalephotoacousticmicroscopy