Cargando…

Application of Intraoperative Optical Coherence Tomography Technology in Anterior Segment Surgery

The use of optical coherence tomography (OCT) technology in anterior segment diseases allows for precise assessment of the changes following anterior segment surgery. Advances in microscope-integrated OCT systems have allowed the utilization of intraoperative OCT (iOCT) in anterior segment surgeries...

Descripción completa

Detalles Bibliográficos
Autores principales: Han, Sang Beom, Liu, Yu-Chi, Mohamed-Noriega, Karim, Mehta, Jodhbir S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9012644/
https://www.ncbi.nlm.nih.gov/pubmed/35433043
http://dx.doi.org/10.1155/2022/1568406
_version_ 1784687840115818496
author Han, Sang Beom
Liu, Yu-Chi
Mohamed-Noriega, Karim
Mehta, Jodhbir S.
author_facet Han, Sang Beom
Liu, Yu-Chi
Mohamed-Noriega, Karim
Mehta, Jodhbir S.
author_sort Han, Sang Beom
collection PubMed
description The use of optical coherence tomography (OCT) technology in anterior segment diseases allows for precise assessment of the changes following anterior segment surgery. Advances in microscope-integrated OCT systems have allowed the utilization of intraoperative OCT (iOCT) in anterior segment surgeries, i.e., cornea, cataract, and refractive surgery. iOCT has enabled real-time precise visualization of anterior segment tissues as well as interactions between surgical instruments and ocular tissue; thus, the device can facilitate surgical procedures and provide valuable information for decision-making during anterior segment surgeries. In this review, the authors will introduce studies regarding the development of iOCT technology and its application in various anterior segment surgeries. Multiple studies have shown the efficacy of the iOCT for intraoperative assistance and guidance, suggesting the potential of the device for optimizing the surgical outcomes after cornea, cataract, and refractive surgery.
format Online
Article
Text
id pubmed-9012644
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-90126442022-04-16 Application of Intraoperative Optical Coherence Tomography Technology in Anterior Segment Surgery Han, Sang Beom Liu, Yu-Chi Mohamed-Noriega, Karim Mehta, Jodhbir S. J Ophthalmol Review Article The use of optical coherence tomography (OCT) technology in anterior segment diseases allows for precise assessment of the changes following anterior segment surgery. Advances in microscope-integrated OCT systems have allowed the utilization of intraoperative OCT (iOCT) in anterior segment surgeries, i.e., cornea, cataract, and refractive surgery. iOCT has enabled real-time precise visualization of anterior segment tissues as well as interactions between surgical instruments and ocular tissue; thus, the device can facilitate surgical procedures and provide valuable information for decision-making during anterior segment surgeries. In this review, the authors will introduce studies regarding the development of iOCT technology and its application in various anterior segment surgeries. Multiple studies have shown the efficacy of the iOCT for intraoperative assistance and guidance, suggesting the potential of the device for optimizing the surgical outcomes after cornea, cataract, and refractive surgery. Hindawi 2022-04-08 /pmc/articles/PMC9012644/ /pubmed/35433043 http://dx.doi.org/10.1155/2022/1568406 Text en Copyright © 2022 Sang Beom Han et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Review Article
Han, Sang Beom
Liu, Yu-Chi
Mohamed-Noriega, Karim
Mehta, Jodhbir S.
Application of Intraoperative Optical Coherence Tomography Technology in Anterior Segment Surgery
title Application of Intraoperative Optical Coherence Tomography Technology in Anterior Segment Surgery
title_full Application of Intraoperative Optical Coherence Tomography Technology in Anterior Segment Surgery
title_fullStr Application of Intraoperative Optical Coherence Tomography Technology in Anterior Segment Surgery
title_full_unstemmed Application of Intraoperative Optical Coherence Tomography Technology in Anterior Segment Surgery
title_short Application of Intraoperative Optical Coherence Tomography Technology in Anterior Segment Surgery
title_sort application of intraoperative optical coherence tomography technology in anterior segment surgery
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9012644/
https://www.ncbi.nlm.nih.gov/pubmed/35433043
http://dx.doi.org/10.1155/2022/1568406
work_keys_str_mv AT hansangbeom applicationofintraoperativeopticalcoherencetomographytechnologyinanteriorsegmentsurgery
AT liuyuchi applicationofintraoperativeopticalcoherencetomographytechnologyinanteriorsegmentsurgery
AT mohamednoriegakarim applicationofintraoperativeopticalcoherencetomographytechnologyinanteriorsegmentsurgery
AT mehtajodhbirs applicationofintraoperativeopticalcoherencetomographytechnologyinanteriorsegmentsurgery