Cargando…
Application of Intraoperative Optical Coherence Tomography Technology in Anterior Segment Surgery
The use of optical coherence tomography (OCT) technology in anterior segment diseases allows for precise assessment of the changes following anterior segment surgery. Advances in microscope-integrated OCT systems have allowed the utilization of intraoperative OCT (iOCT) in anterior segment surgeries...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9012644/ https://www.ncbi.nlm.nih.gov/pubmed/35433043 http://dx.doi.org/10.1155/2022/1568406 |
_version_ | 1784687840115818496 |
---|---|
author | Han, Sang Beom Liu, Yu-Chi Mohamed-Noriega, Karim Mehta, Jodhbir S. |
author_facet | Han, Sang Beom Liu, Yu-Chi Mohamed-Noriega, Karim Mehta, Jodhbir S. |
author_sort | Han, Sang Beom |
collection | PubMed |
description | The use of optical coherence tomography (OCT) technology in anterior segment diseases allows for precise assessment of the changes following anterior segment surgery. Advances in microscope-integrated OCT systems have allowed the utilization of intraoperative OCT (iOCT) in anterior segment surgeries, i.e., cornea, cataract, and refractive surgery. iOCT has enabled real-time precise visualization of anterior segment tissues as well as interactions between surgical instruments and ocular tissue; thus, the device can facilitate surgical procedures and provide valuable information for decision-making during anterior segment surgeries. In this review, the authors will introduce studies regarding the development of iOCT technology and its application in various anterior segment surgeries. Multiple studies have shown the efficacy of the iOCT for intraoperative assistance and guidance, suggesting the potential of the device for optimizing the surgical outcomes after cornea, cataract, and refractive surgery. |
format | Online Article Text |
id | pubmed-9012644 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-90126442022-04-16 Application of Intraoperative Optical Coherence Tomography Technology in Anterior Segment Surgery Han, Sang Beom Liu, Yu-Chi Mohamed-Noriega, Karim Mehta, Jodhbir S. J Ophthalmol Review Article The use of optical coherence tomography (OCT) technology in anterior segment diseases allows for precise assessment of the changes following anterior segment surgery. Advances in microscope-integrated OCT systems have allowed the utilization of intraoperative OCT (iOCT) in anterior segment surgeries, i.e., cornea, cataract, and refractive surgery. iOCT has enabled real-time precise visualization of anterior segment tissues as well as interactions between surgical instruments and ocular tissue; thus, the device can facilitate surgical procedures and provide valuable information for decision-making during anterior segment surgeries. In this review, the authors will introduce studies regarding the development of iOCT technology and its application in various anterior segment surgeries. Multiple studies have shown the efficacy of the iOCT for intraoperative assistance and guidance, suggesting the potential of the device for optimizing the surgical outcomes after cornea, cataract, and refractive surgery. Hindawi 2022-04-08 /pmc/articles/PMC9012644/ /pubmed/35433043 http://dx.doi.org/10.1155/2022/1568406 Text en Copyright © 2022 Sang Beom Han et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Review Article Han, Sang Beom Liu, Yu-Chi Mohamed-Noriega, Karim Mehta, Jodhbir S. Application of Intraoperative Optical Coherence Tomography Technology in Anterior Segment Surgery |
title | Application of Intraoperative Optical Coherence Tomography Technology in Anterior Segment Surgery |
title_full | Application of Intraoperative Optical Coherence Tomography Technology in Anterior Segment Surgery |
title_fullStr | Application of Intraoperative Optical Coherence Tomography Technology in Anterior Segment Surgery |
title_full_unstemmed | Application of Intraoperative Optical Coherence Tomography Technology in Anterior Segment Surgery |
title_short | Application of Intraoperative Optical Coherence Tomography Technology in Anterior Segment Surgery |
title_sort | application of intraoperative optical coherence tomography technology in anterior segment surgery |
topic | Review Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9012644/ https://www.ncbi.nlm.nih.gov/pubmed/35433043 http://dx.doi.org/10.1155/2022/1568406 |
work_keys_str_mv | AT hansangbeom applicationofintraoperativeopticalcoherencetomographytechnologyinanteriorsegmentsurgery AT liuyuchi applicationofintraoperativeopticalcoherencetomographytechnologyinanteriorsegmentsurgery AT mohamednoriegakarim applicationofintraoperativeopticalcoherencetomographytechnologyinanteriorsegmentsurgery AT mehtajodhbirs applicationofintraoperativeopticalcoherencetomographytechnologyinanteriorsegmentsurgery |