Cargando…
Determination of exercise intensity domains during upright versus supine cycling: a methodological study
BACKGROUND: There is a growing interest among the research community and clinical practitioners to investigate cardiopulmonary exercise test (CPET) procedures and protocols utilized in supine cycling. MATERIALS AND METHODS: The current study investigated the effects of posture on indicators of exerc...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
PeerJ Inc.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9013233/ https://www.ncbi.nlm.nih.gov/pubmed/35437475 http://dx.doi.org/10.7717/peerj.13199 |
_version_ | 1784687951643410432 |
---|---|
author | Zubac, Damir Ivančev, Vladimir Martin, Vincent Dello Iacono, Antonio Meulenberg, Cécil J.W. McDonnell, Adam C. |
author_facet | Zubac, Damir Ivančev, Vladimir Martin, Vincent Dello Iacono, Antonio Meulenberg, Cécil J.W. McDonnell, Adam C. |
author_sort | Zubac, Damir |
collection | PubMed |
description | BACKGROUND: There is a growing interest among the research community and clinical practitioners to investigate cardiopulmonary exercise test (CPET) procedures and protocols utilized in supine cycling. MATERIALS AND METHODS: The current study investigated the effects of posture on indicators of exercise intensity including gas exchange threshold (GET), respiratory compensation point (RCP), and the rate of peak oxygen uptake (V̇O(2) peak), as well as the role of V̇O(2) mean response time (MRT) in determining exercise intensity domains in nineteen healthy men (age: 22 ± 3 years). Two moderate-intensity step-transitions from 20 to 100 Watt (W) were completed, followed by a maximal CPET. After completing the ramp test, participants performed a constant-load at 90% of their attained peak power output (PPO). RESULTS: No differences were observed in the V̇O(2) MRT between the two positions, although the phase II-time constant (τV̇O(2p)) was 7 s slower in supine position compared to upright (p = 0.001). The rate of O(2) uptake in the supine position at GET and RCP were lower compared to the upright position (208 ± 200 mL·min(−1) (p = 0.007) and 265 ± 235 mL·min(−1) (p = 0.012) respectively). Besides, V̇O(2) peak was significantly decreased (by 6%, p = 0.002) during supine position. These findings were confirmed by the wide limits of agreement between the measures of V̇O(2) in different postures (V̇O(2) peak: −341 to 859; constant-load test: −528 to 783; GET: −375 to 789; RCP: −520 to 1021 all in mL·min(−1)). CONCLUSION: Since an accurate identification of an appropriate power output (PO) from a single-visit CPET remains a matter of debate, especially for supine cycling, we propose that moderate-intensity step-transitions preceding a ramp CPET could be a viable addition to ensure appropriate exercise-intensity domain determination, in particular upon GET-based prescription. |
format | Online Article Text |
id | pubmed-9013233 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | PeerJ Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-90132332022-04-17 Determination of exercise intensity domains during upright versus supine cycling: a methodological study Zubac, Damir Ivančev, Vladimir Martin, Vincent Dello Iacono, Antonio Meulenberg, Cécil J.W. McDonnell, Adam C. PeerJ Public Health BACKGROUND: There is a growing interest among the research community and clinical practitioners to investigate cardiopulmonary exercise test (CPET) procedures and protocols utilized in supine cycling. MATERIALS AND METHODS: The current study investigated the effects of posture on indicators of exercise intensity including gas exchange threshold (GET), respiratory compensation point (RCP), and the rate of peak oxygen uptake (V̇O(2) peak), as well as the role of V̇O(2) mean response time (MRT) in determining exercise intensity domains in nineteen healthy men (age: 22 ± 3 years). Two moderate-intensity step-transitions from 20 to 100 Watt (W) were completed, followed by a maximal CPET. After completing the ramp test, participants performed a constant-load at 90% of their attained peak power output (PPO). RESULTS: No differences were observed in the V̇O(2) MRT between the two positions, although the phase II-time constant (τV̇O(2p)) was 7 s slower in supine position compared to upright (p = 0.001). The rate of O(2) uptake in the supine position at GET and RCP were lower compared to the upright position (208 ± 200 mL·min(−1) (p = 0.007) and 265 ± 235 mL·min(−1) (p = 0.012) respectively). Besides, V̇O(2) peak was significantly decreased (by 6%, p = 0.002) during supine position. These findings were confirmed by the wide limits of agreement between the measures of V̇O(2) in different postures (V̇O(2) peak: −341 to 859; constant-load test: −528 to 783; GET: −375 to 789; RCP: −520 to 1021 all in mL·min(−1)). CONCLUSION: Since an accurate identification of an appropriate power output (PO) from a single-visit CPET remains a matter of debate, especially for supine cycling, we propose that moderate-intensity step-transitions preceding a ramp CPET could be a viable addition to ensure appropriate exercise-intensity domain determination, in particular upon GET-based prescription. PeerJ Inc. 2022-04-13 /pmc/articles/PMC9013233/ /pubmed/35437475 http://dx.doi.org/10.7717/peerj.13199 Text en © 2022 Zubac et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, reproduction and adaptation in any medium and for any purpose provided that it is properly attributed. For attribution, the original author(s), title, publication source (PeerJ) and either DOI or URL of the article must be cited. |
spellingShingle | Public Health Zubac, Damir Ivančev, Vladimir Martin, Vincent Dello Iacono, Antonio Meulenberg, Cécil J.W. McDonnell, Adam C. Determination of exercise intensity domains during upright versus supine cycling: a methodological study |
title | Determination of exercise intensity domains during upright versus supine cycling: a methodological study |
title_full | Determination of exercise intensity domains during upright versus supine cycling: a methodological study |
title_fullStr | Determination of exercise intensity domains during upright versus supine cycling: a methodological study |
title_full_unstemmed | Determination of exercise intensity domains during upright versus supine cycling: a methodological study |
title_short | Determination of exercise intensity domains during upright versus supine cycling: a methodological study |
title_sort | determination of exercise intensity domains during upright versus supine cycling: a methodological study |
topic | Public Health |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9013233/ https://www.ncbi.nlm.nih.gov/pubmed/35437475 http://dx.doi.org/10.7717/peerj.13199 |
work_keys_str_mv | AT zubacdamir determinationofexerciseintensitydomainsduringuprightversussupinecyclingamethodologicalstudy AT ivancevvladimir determinationofexerciseintensitydomainsduringuprightversussupinecyclingamethodologicalstudy AT martinvincent determinationofexerciseintensitydomainsduringuprightversussupinecyclingamethodologicalstudy AT delloiaconoantonio determinationofexerciseintensitydomainsduringuprightversussupinecyclingamethodologicalstudy AT meulenbergceciljw determinationofexerciseintensitydomainsduringuprightversussupinecyclingamethodologicalstudy AT mcdonnelladamc determinationofexerciseintensitydomainsduringuprightversussupinecyclingamethodologicalstudy |